Home Companies Guangzhou YIGU Medical Equipment Service Co.,Ltd

Normal Standard Package Medical Equipment Accessories M1572A Cuff Paediatric

Guangzhou YIGU Medical Equipment Service Co.,Ltd

Contact Us

[China] country

Trade Verify

Address: Room 206, Jin Hao Zhi Ying centre Buliding, Fengxin Road NO.1, Science avenue, Luo Gang District Guangzhou Guangdong China

Contact name:chamY

Inquir Now

Guangzhou YIGU Medical Equipment Service Co.,Ltd

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

Normal Standard Package Medical Equipment Accessories M1572A Cuff Paediatric

Country/Region china
City & Province guangzhou guangdong
InquireNow

Product Details

Medical M1572A Cuff Paediatric Shipping Time within A Week after Payment All Over the World

 

  1. CABLE ASSY ECG MLT-LNK 3/5 LEAD 3.6M AHA

  2. LDWR AHA 5LD GRAB SH MOLDED

  3. Ldwr Set, Multi-Link Snap 29In AHA

  4. Covidien Interface Cable

  5. Covidien Compatible Finger Sensor,with DB9 connector 1M

  6. CABLE ASSY SPO2 Covidien OXIMAX 3M

  7. DS1--A Covidien DuraSensor Reusable Finger Probe DS100A (1/box)

  8. Ohmeda SPO2 Finger Sensor

  9. NIBP Dual Tube BP Tubing, Adult 3.6M for Dash and Tram

  10. DURA-CUF* Cuff, Adult, 2-Tube Sub-Min, Navy,

  11. CARDIOSERV battery BTRY RECHGR NICD SCP

  12. CARDIOSERV PADDLE PAIR DEFIB CSERV

  13. MAC1200 MAC800 Cable,Leadwire

  14. MAC800 battery

  15. MAC5000 CABLE ASSY HOST CASE

  16. CAM 14 Leadwire Set, 10 Lead, Banana, AHA, Mixed Lengths

  17. SEER Light patient cable 3 Channel

  18. CORO170 U/S XDCR WATERTIGHT BUTTON 8' CABLE

  19. CORO170 TOCO XDCR WATERTIGHT BUTTON 8' CABLE

  20. CABLE LEAD SET, ECG, 72 in. WIRES

 

Company Strengths:

  • 1. We are able to provide all kinds of medical equipment parts, hospital devices, patient facility accessories and complete machines.
  • 2. We are able to offer maintenance service by professional medical equipment engineer with over 10 years specialized skills.
  • 3. We have been solved more than 90% of MP series medical patient monitor module malfunctions (including software and hardware), and repair M3001A modules more than 400 pcs every year.
  • 4. We deal with all medical patient monitors’ main brands including: GE, , SPACELABS, SIEMENS, NIHON KOHDEN, MINDRAY, Endoscopy, TYCO, NONIN etc.
  • 5.Our principle: integrity and pragmatic, efficient and innovative, fearless and careful, professional service.

 

 

Our Company Business Scopes

  • 1. Maintenance Services: ECG monitor, Defibrillator, Oximeter, Electrocardiograph, Fetal monitor
  •  
  • 2. Sell and Replace: Mainboard, Circuit board, Power strip/ panel, Battery, SP O2 and ECG module, Parameter module, Display screen, Touch screen, Encoder, Keyboard plate, Sensor, Probe, Cable etc.
  •  
  • 3. Service Brands: GE, , SPACELABS, SIEMENS, MINDRAY, NIHON KOHDEN, Endoscopy, TYCO, NONIN, TOSHIBA, MEDISON, BIOSOUND, HITACHI, HP, ATL, ALOKA etc.

 

  • Agilent M1460A Sensor, Intellivue G5-M109A, Intellivue MX40,
  • M1205A , M1001A, M1012A, M1034A, M3001A, M3012A,M3014A, M3015A,M3046A,
  • MP2 X2,MP20,MP30, MP40, MP5, MP50 , MP60, MP70, MP80, MP90,
  • V24E(M1204A), VM4, VM6, VM8,VS2+, VS3
GE

 

  • B20, B20i, B30, B40, B40i, B650, B850,
  • DASH1800, DASH2000, DASH2500, DASH3000, DASH5000, Cardiocap 5,
  • Datex-Ohmeda S3/S4/S5, GE DT-4500, Marquette EAGLE 4000,
  • PRO1000, PRO300,
  • SOLAR8000, SOLAR8000i, SOLAR8000M,
  • V100, SAM Smart, SAM80
Nihon Kohden

 

  • BSM-2301A, BSM-2301K, BSM-2304A, BSM-2351A, BSM-2351C, BSM-4104A, BSM-5106A
  • GF-210R, MU-631KA, WEP-4204K, WEP-4208A
Mindray

 

  • IMEC8, IMEC10, IMEC12,
  • IPM8, IPM10, IPM12, IPM9800, MEC-1000, MEC-1200, MEC-200, MPM,
  • PANORAMA, PM6000, PM1000, PM8000, PM8000E, PM9000, PM9000E,
  • T1, T5, T6, T8, VS-800
Spacelabs

 

  • 90309, 90369, 90518,91369, 91370, 91387, 91388, 91393, 91496, 91518,
  • elance93300,mCare300
Siemens
  • SC6002,SC6000,SC7000,SC6002 XL
Tyco
  • NBP4000, NBP4000C

 

Common Faults Repair
1. Unbootable/ Unable to boot up2. The module ( M3001A ) can’t detect blood pressure.
3. The module can’t be connected.4. Automatically disconnect.
5. The sphygmomanometer has a leak.6. NIBP equipment failure.
7. Unable to contact.8. Error reporting MMS disconnected.
9. False alarm MMS pull out.10. Can’t load out.
11. ECG malfunctions.12. ECG equipment out of order.
13. Software upgrades.14. NIBP fails to inflate.
15. IBP equipment faults.16. M3012A module can’t be detected.
17. Automatically restart.18. The encoder can’t work.
19. Blue screen appears after startup.20. No ECG signal.
21. Unable to enter the select menu.22. Alarm occurs when starting up, and the failure light is on.
23. Report CO2 plugging.24. MMSL developing module faults.
25. M3015A / M3001A module faults.26. No power display light.
27. NBP equipment faults.28. ECG and oximeter equipment faults.
29. LCD lamp aging.30. Inflated blood pressure does not indicate a number.
31. The key plate is out of order.32. Encoder failure.
33. Can’t inflate.34. NIBP equipment faults.
35. SP O2 and ECG equipment fault.36. Unable to charge.
37. The touch screen can’t work.38. The screen shows double image.
39. Error code 1000. Error code 20004.40. No alarm sounds.

 

Hot Products

Goldway UT4000 Patient Monitor Mainboard PCB Board PN:C-ARM211B From Yigu Medical Repairing Services ...
Mindray PN:6800-30-50503 AG GAS Anesthesia Module In Stocks For Repairing Services With 3Months ...
Medical Accessories Mindray VS900 Monitor NIBP with Valve PN:051-000929-00 In Stocks For Selling ...
GE 170 Series fetal monitor repair For medical patient monitor GE 170 Series fetal monitor repair ...
Medical Accessories Drager REF 8403735 Flow Sensor In Stocks For Selling About YIGU MED Guangzhou ...
Medical Facility GE Corometrics 120Series Fetal Monitor in Stocks For Selling and Repairing Services ...