Ningbo Anyo Import & Export Co., Ltd. |
22 * 7mm passive piezo buzzer DC 1 ~ 20V , minimum 85dB at 10cm
Description:
A buzzer is an audio signaling device, which may be mechanical
, electromechanical , or piezoelectric (piezo for short). Typical
uses of buzzers include alarm devices , timers, and confirmation of
user input such as a mouse click or keystroke.
Piezo buzzer is an electronic device commonly used to produce
sound. Light weight, simple construction and low price make it
usable in various applications like car/truck reversing indicator,
computers, call bells etc. Piezo buzzer is based on the inverse
principle of piezo electricity discovered in 1880 by Jacques and
Pierre Curie. It is the phenomena of generating electricity when
mechanical pressure is applied to certain materials and the vice
versa is also true. Such materials are called piezo electric
materials. Piezo electric materials are either naturally available
or manmade. Piezoceramic is class of manmade material, which poses
piezo electric effect and is widely used to make disc, the heart of
piezo buzzer. When subjected to an alternating electric field they
stretch or compress, in accordance with the frequency of the signal
thereby producing sound.
The piezo buzzer produces sound based on reverse of the
piezoelectric effect. The generation of pressure variation or
strain by the application of electric potential across a
piezoelectric material is the underlying principle. These buzzers
can be used alert a user of an event corresponding to a switching
action, counter signal or sensor input. They are also used in alarm
circuits.
The buzzer produces a same noisy sound irrespective of the voltage
variation applied to it. It consists of piezo crystals between two
conductors. When a potential is applied across these crystals, they
push on one conductor and pull on the other. This, push and pull
action, results in a sound wave. Most buzzers produce sound in the
range of 2 to 4 kHz.
Our buzzers are widely used to inquartzcrystal clock,
air-conditioner instrument, telephone, BP, copycat, alarm,
instrument and apparatus, UPS power supply, motorcycle steering
gear, electronic toy, computer terminal, electronic watch and
etc.
Dimension: (mm)
Frequency response:
Reliability test:
ITEM | METHOD OF TEST | STANDARD |
Dry heat test | After being placed in a chamber with +70±2℃ for 96 hours and then being placed in natural condition for 2 hours, sounder shall be measured. | All specification must be satisfied after the test. |
Cold test | After being placed in a chamber with -20±2℃ for 96 hours and then being placed in natural condition for 2 hours, sounder shall be measured. | All specification must be satisfied after the test. |
Humidity Test | After being placed in a chamber with, 90%-95%R.H. at +40℃±2℃ for 96 hours and then being placed in natural condition for 2 hours, sounder shall be measured. | All specification must be satisfied after the test. |
Temperature Cycle Test | After being placed in a chamber at -20℃±2℃ for 30 minutes, sounder shall be placed at room temperature(+20℃). After 15 minutes at this temperature, sounder shall be placed in a chamber at +70℃±2℃. After 30 minutes at this temperature, sounder shall be returned to room temperature(+20℃) for 15 minutes. After 5 above cycles, sounder shall be measured after being placed in natural condition for 2 hours. | All specification must be satisfied after the test |
Vibration Test | Sounder shall be measured after being applied vibration of amplitude of 1.5mm with 10-55Hz band of vibration frequency for 30 minutes. Sweep time is 1 minute. | All specification must be satisfied after the test. |
Shock Test | Sounder shall be measured after being applied shock (100G) for each three mutually perpendicular directions to each of 3 times. | All specification must be satisfied after the test. |
Terminal Strength Pulling Test | The force 5 seconds of 5N is applied to each terminal. No visible damage and cutting off. | All specification must be satisfied after the test. |
Solder ability Test | Lead terminals are immersed in rosin for 5 seconds and then immersed in solder bath of +255±5℃ for 3±0.5 seconds. | All specification must be satisfied after the test. |