Passive SD150 telephone dynamic receiver for mobile phone, Φ38mm 150Ω
 
Specifications:

 

TypeDynamic receiver unit
DimensionExternal diameter 38mm
Sensitivity(S.P.L)93dB ±3dB at 1kHz 60mV with IEC 318 coupler
Frequency responseRefer to frequency response chart
Impedance150OHM ±20% at 1 KHz
Magnet field intensityAxial - dB, Radial - dB at 1KHz
Max. input powerMust be normal at a white noise, 50mW for 1 minute
Weight35g±2g
AppearanceShould not exist any obstacle to be harmful to normal operation: damages, cracks, rusts, and distortions, etc.
Buzzer, rattle, etc.Should not be audible at 1V sine wave between 300Hz to 3.4KHz
Terminal strengthCapable of withstanding 1KG load for 15 sec. without resulting in any damage or rejection
Load test1mW white noise(-filter) is applied for 72 hours satisfy the tests listed on item 03,04,09 and 10

 

Environmental test:

 

Sensitivity difference shall be within ±3dB and should satisfy the listed on item 03,04,09 and 10, after each following test.

 

Thermal cycle test

Low temperature -40℃±3℃

Temperature:+70℃±3℃

Cycle: 6 hour/cycles each, and then keep 2 hours in a room.

High temperature. testKeep 96 hours at +70℃±3℃ and leave 6 hours in normal temperature and then check.
Low temperature testKeep 96 hours at -40℃±3℃ and leave 6 hours in normal temperature and then check.
Humidity testKeep 96 hours at +40℃±3℃ and relative humidity 95% and leave 3 hours in normal temperature and then check.
Drop testDrop the handset mounted a unit onto a board 5mm thick 18 times from the height of 1m and them should satisfy the test listed on item 09 and 10.


Measurement condition:

 

Test and measurement will be carried out under normal condition of temperature within 5℃ to 35℃, relative humidity within 45% to 85% and air pressure of 860mbar to 1060mbar.

Should uncertainly arise in data obtained from the above atmosphere, control of temperature at 20℃±2℃ and relative humidity within 60% and 70%, with air pressure remaining unchanged, to be enforced.

 

Test signal60mV
Sweep freq.responseApply test signal varying logarithmical from 100Hz to 10KHz, 2 times for 0.5 second.
S.P.L(Sensiticity)Read out average figure of S.P.L meter needle
Freq. response curveApply test signal and check response curve with frequency response recorder.


 

Dimension: (mm)

 

Hot Products

26mm Band Selector Rotary Switch, 1 pole 12 position with 6mm shaft Description: A rotary switch is ...
Φ17mm Single Turn Carbon Film Rotary Potentiometer With Switch RV17-K2 Application: Ideal for ...
Φ24mm adjustable resistance dimmer with switch potentiometer WH138-1 Application: Ideal for ...
Pin type WH138-4 potentiometer with switch dimmer switch speed controller Application: Ideal for ...
Metal Shaft 1W Single Turn Wirewound Rotary Potentiometer WX118 Features: • Long life • Dust proof ...
17mm Dimmer Potentiometer SPDT With Push Switch 10A 250VAC WH116AK Features: • VDE, NEMKO, CB ...