Home Companies Tianjin Estel Electronic Science and Technology Co.,Ltd

DC / AC 1000VA Sine Wave Inverter Flush Mounting Power Supply AC Bypass Input

Tianjin Estel Electronic Science and Technology Co.,Ltd

Contact Us

[China] country

Trade Verify

Address: Shenzhen, China

Contact name:Fiona Liang

Inquir Now

Tianjin Estel Electronic Science and Technology Co.,Ltd

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

DC / AC 1000VA Sine Wave Inverter Flush Mounting Power Supply AC Bypass Input

Country/Region china
City & Province shenzhen guangdong
Categories Inverters & Converters
InquireNow

Product Details

 

 

AC Bypass input RS485 Communication Function DC / AC 1000VA Sine Wave Inverter Flush Mounting Power Supply

 

1. Product Description

 

 

GPDA1000VA-F is one kind of two outputs, with AC bypass input, with 485 communication function DC / AC 1000VA sine wave inverter flush mounting power supply, the entire power supply using the latest circuit design, compact structure, reliable performance, high output efficiency. Entire power in strict accordance with safety requirements designed to meet the IT equipment safety standards.

 

2.  Electrical Specifications

 

Input
ParameterMin.TypicalMax.UnitNote
DC inputDC operating voltage range40 60Vdc 
Input rated voltage 48 Vdc 
Input Rated Current  30ARated input, rated output
Power input Max Surge Current  45A≤ 150% of rated current
AC inputAC operating voltage range175 265Vac 
Input rated voltage 220 Vac 
Input Rated Current  5A 
 

 

Export
ParameterMin.TypicalMax.UnitNote
The inverter outputRated output voltage 220 VacEnter the full voltage range
Rated output current 4.6 A 
Output voltage accuracy  ±5%Enter the full voltage range
Rated output frequency495051Hz 
Rated Capacity  1000VA 
Rated output power  1000W 
Overall efficiency85  %Rated operating conditions
Output power factor0.8   Rated operating conditions
Dynamic transient recovery time  60ms 
WaveformSine wave THD <3% (linear load)
Sine wave THD <8% (linear load)
Overload105~ 125% for not less than 10 minutes to 125 to 150% for not less than 10 seconds.
Output current crest factor3: 1
OutputTwo AC output
AC bypass outputOutput voltage range175 265VacWith the AC input voltage changes
Rated output voltage 220 Vac 
Rated output current  5A 
Switch to mains inverter output time  10msRated load
Mains to inverter output time  10msRated load
OutputTotal output of the inverter, the inverter when an input under voltage, overvoltage, fan failure, over-temperature protection, switching to bypass output.
 

Protection
ParameterMin.TypicalMax.UnitNote
Inverter partDC input voltage protection point36  VdcEnter under voltage protection, the inverter output bypass switch.
DC input voltage recovery point  40VdcAchieve recovery value, one minute to restore the inverter output.
DC input voltage recovery hysteresis2  Vdc 
DC input voltage protection point  66VdcEnter overvoltage protection, the inverter switch to bypass the output.
DC input overvoltage recovery point60  VdcAchieve recovery value, one minute to restore the inverter output.
DC input overvoltage recovery hysteresis2  Vdc 
Input over current protectionPower supply with input over current protection, can not be automatically restored.
Over Temperature ProtectionPower supply with over-temperature protection. When inside the main heat sink temperature is too high, over-temperature protection point reached, the inverter output bypass switch, temperature hysteresis of 10℃ or so.
Anti-reverse protectionPower supply with input anti-reverse protection. When reversed, the power does not work, and no damage.
Short circuit protectionPower supply with short circuit protection. When the power fails short intervals of one minute start time, 6 minutes lift failure, can be recovered. Long-short, the power shutdown, the short is removed, you can manually re-boot after work.
Output over current protectionPower supply with over current protection. Detect over current, output power is turned off, every one minute start time, when the load back to the ratings, self-recovery. Long-term overload, power off, you can manually reboot after work.
Alarm (buzzer alarm)DC input error, overload, short circuit, inverter fault, the buzzer alarm.
AC bypass sectionInput over current protectionBypass input section having an input over current protection function (≥ 10 A), non-self-recovery. The need to manually replace the fuse before working again.
 

 

Environment
ParameterMin.TypicalMax.UnitNote
Operating ambient temperature- 20 +5 5° C 
Inverter temperature storage environment- 25 +70° C 
Relative humidity0 95%Relative humidity, dew does not pour
Altitude  15 00mMeet derating requirementsGB3859.2-93
CoolingNatural air. With the power of wind turbines internal temperature rises enhanced, cold heat.
Work EnvironmentNo conductive dust explosion, corrosion and destruction of gases and vapors, no severe vibration and shock
 

 

5. Product Dimensions

 

6. Product Pictures

 

 

 

 

 

 

Hot Products

Galvanized Steel Integrated Outdoor Power Cabinet 120W/K Heat Exchanger Cooling System 1. Product ...
Telecommunication Outdoor Battery Telecom Cabinet With Heat Exchanger Floor Mounting 1. Product ...
2000W Cooling Capacity Air Condirtioner Sandwich Structure Outdoor Telecom Cabinet Floor Mounting ...