Custom Galvanized Steel Outdoor Power Enclosure Equipment Rack Cabinet

Country/Region china
City & Province shenzhen guangdong
Categories Mobile Phone Chargers
InquireNow

Product Details

 

Custom Galvanized Steel Outdoor Power Enclosure Equipment Rack Cabinet

 

Quick Details:

 

Place of Origin: Shenzhen, China (Mainland)External Size W×D×H 900×900×1800mm

      Band Name: ESTEL

 

Structure: double wall, with insulation, sandwich structure
Model Number: ET9090180-UPCabinet Layout: one compartments: the upper part is equipment compartment, the lower part is battery compartment
Product Name: Outdoor Power CabinetCabinet Lock: anti-theft three point lock
Certification: ISO9001, CE, 3C, FCC, TLC, IP55Protection Level: IP55
Application: outdoor telecom base stationCable Entry: at cabinet bottom
Material: galvanized steelIllumination: DC48V LED lamp
Heat Insulation: PEFGrounding Protection: copper bar
Color: grey (support custom made)Cooling: AC220V air conditioner and DC48V thermoelectric cooler
Coating: anti-corrosion outdoor powder coatingAccessories Options: PDU, rectifier system, environment monitoring system

 

1. Technical Parameters

 

ItemTypeTechnical Parameter
StructureDimensionExternal Dimension: W×D×H 900×900×1800mm
Layout1 compartment
Equipment Installation MethodUpper compartment: 19” rack; Lower compartment: battery shelf.
DoorWith one front door, and special lock for outdoor cabinet (support padlock)
MaterialGalvanized steel, 1.5mm thick outer plate, 0.8mm thick inner plate
Heat InsulationThere are heat insulation between inner wall and outer wall. The insulation material is 20mm PEF.
Ingress ProtectionIP55
Temperature ControlCoolingAC220V air conditioner and DC48V TEC air conditioner
Lightning ProofGrade B lightning proofNominal: 60KA, Max.: 100KA
LightingLED lamp48V LED lamp
TemperatureTemperatureWorking Temperature: -40°C ~ +55°C
  Storage Temperature: -50°C ~ + 70°C
  Transport Temperature: -50°C ~ +70°C
HumidityRelative Humidity5% ~ 100%
PressureAir Pressure62kpa ~ 101kpa (similar to 0m ~ 5000m altitude)
Radiation IntensitySolar Radiation Intensity1120 ×(1±5%)W/m2

 

2. Accessories List

 

No.ItemQuantityUnitSpecs
1Outdoor Telecom Cabinet1Set

(1) External Dimension: W*D*H 900*900*1800mm

(2) Two compartments: the upper part is equipment compartment, the lower part is battery compartment

(3) With one front door, and special lock for outdoor cabinet (support padlock)

(4) Material: galvanized steel; 1.5mm thick outer plate, 0.8mm thick inner plate;

(5) There are heat insulation between inner wall and outer wall. The insulation material is 20mm PEF.

2

Air Conditioner

(cooling for equipment compartment)

1Set

Cooling capacity: 1000W;

Power Supply: AC220V, 50HZ;

Model: TC06-100JFH/01.

3

TEC Air Conditioner

(cooling for battery compartment)

1Set

Cooling capacity: 200W;

Power Supply: DC48V;

Model: TC06-20TEH/01.

4Environment Monitoring Unit1Set19”, 1U; Model: SM2400.
5Door Sensor2PCOne for controlling LED lamp, one for open door alarm.
6Smoke Sensor1PC 
7Water Sensor1PC 
8Temperature and Humidity Sensor1PC 
9LED Lamp1PCDC48V
10Power Distribution Unit1Set

Grade B Lightning Proof

AC Input: 63A/2P *1;

AC Output: 16A/1P*4;

DC Output: 16A/1P*4

Input Voltage: AC220V.

11Rectifier System1Set

Model: GPE4890J (DC48V, 90A)

Including:

(1) 3×30A Rectifier Module;

(2) 1× Monitoring Module;

(3) Power distribution frame.

12Package1SetWooden Case

 

3. Cabinet Dimension

 

 

4. Application

 

The ET9090180-UP outdoor power supply cabinet is mainly used in wireless communication base station, such as 4G system, communication/network integrated service, access/transmission switching station, emergency communication/transmission, etc.

 

5. Features

 

  • The cabinet is dustproof, sunproof and rainproof, which is used in outdoor environment.
  • Cabinet cooling: air conditioner. MTBF≥50000h.(other option: heat exchanger and fans).
  • Including -48VDC illumination LED lamp.
  • The cabinet includes power and environment monitoring unit, which can send power failure alarm, door open alarm, temperature and humidity alarm, smoke alarm, water alarm etc.
  • The layout of the cabinet is reasonable, which will facilitate cable access, fixing and grounding. At the bottom of the cabinet, there are cable inlets separately for power cable, signal cable and optical cable.
  • All the cables, sealing and heat insulation used in the cabinet are made from flame retardant materials.
  • The cabinet includes 19” standard installation rack and battery shelf.
  • Surface treatment: degreasing, derusting, rustproof phosphating (or galvanizing), powder coated.
  • Cabinet load bearing: ≥600kg
  • Flame retardance: comply with GB5169.7 test A
  • Insulation resistance: the insulation resistance between grounding devices and cabinet body parts is not lower than 2×104M/500V(DC).
  • Withstand voltage: the withstand voltage between grounding devices and cabinet body parts is not lower than 3000V(DC)/1min.
  • Mechanical strength: each surface can bear upright pressure >980N; after the door is open, its outer end can bear upright pressure >200N.

 

6. Components Installation

 

6.1 LED lamp, LED lamp sensor, smoke sensor, door sensor and temperature & humidity sensor are installed at the top of the cabinet.

 

 

6.2 Water sensor is installed at the bottom of the cabinet.

 

 

 

6.3 PDU, environment monitoring unit and rectifier system are installed on 19” rack.

 

6.4 The cabinet includes totally two air conditioners, installed on front door.

 

6.5 The cabinet includes rubber base plate, for installation on transport telecom tower trailer.

 

 

7. Cable Inlet

 

Feeder cable and other external cables all use bottom wiring method.

 

 

8. Grounding Protection

 

  • The cabinet includes grounding copper bar with anti-corrosion coating. There are enough screws for wiring connection terminals.
  • The metal part of the cabinet should be interconnected and be connected with grounding bar. Connection resistance between any two points is lower than 0.1Ω.
  • Protective earthing of other equipments inside the cabinet should be connected to the grounding bar.

 

9. Theft Proof Design

9.1 Door lock theft proof design

 

  • Damage resistance of the theft proof lock meets GA/T 73-1994 “Mechanical Anti-theft Lock” class B requirement, supporting padlock.

  • Three point lock

9.2 Connection and Fastening

 

  • Use anti-loose threaded connection as structure and bearer connection. Anchor bolt for fixing cabinet use hot dip galvanized bolts.
  • Door hinges use inner hinge mode.

 

9.3 Appearance and Surface Treatment

 

Cabinet surface coating is outdoor special powder coating, with white gray color (PANTONE 428C). The coating complies with GB/T 3181-2008 requirement.

 

10. PDU Principle Diagram

 

11. Air Conditioner

 

(1) Thermoelectric Cooler (Peltier) Air Conditioner.

Model: TC06-20TEH/01.

Power Supply: DC48V.

Cooling Capacity: 200W.

Quantity: 1 set

 

(2) Compressor Air Conditioner.

Model: TC06-100JFH/01.

Power Supply: AC220V 50Hz

Cooling Capacity: 1000W.

Quantity: 1 set

 

12. Environment Monitoring System

 

The environment monitoring system includes:

1× environment monitoring unit, with TCP/IP communication port;

1× water sensor;

1× smoke sensor;

1× temperature and humidity sensor;

2× door sensor.

 

13. Packing and Shipping

 

 

Our Delivery Agent

 

The goods can be shipped by sea, by air, by courier, by land, by train, etc.

Besides the following delivery agent, we can also look for the delivery agent with the best price in china if you need us to do for you.

 

14. Our Contact Information

 

Mobile Phone: 0086-13752765943

Telephone: 0086-0755 66600941

Email: info@estel.com.cn

           lxf.estel@hotmail.com
Skype: fiona.liang10

Hot Products

19 Inch Double Wall Green Outdoor Telecom Cabinet For Wireless Communication Base Station 1. ...
Anti Corrosion Powder Coated Thermostatic Outdoor Telecom Cabinet With Front and Rear Access 1. ...
Small Size Outdoor Telecom Equipment Cabinets Customized Sheet Metal Box With Heat Exchanger 1. ...
Stainless Steel Outdoor Telecom Cabinet With Cooling System / Air Conditioner Type Telecom Enclosure ...
Single Wall Stainless Steel Heat Insulation 38U Outdoor Telecom Cabinet 750x700x2000 With DC Air ...
Temperature Control Custom-Made Outdoor Telecom Cabinet With Front Door And Back Door Antitheft 1. ...