Home Companies Tianjin Estel Electronic Science and Technology Co.,Ltd

Generator Compartment Base Station Cabinet With Solar Controller / Solar Cell Panel

Tianjin Estel Electronic Science and Technology Co.,Ltd

Contact Us

[China] country

Trade Verify

Address: Shenzhen, China

Contact name:Fiona Liang

Inquir Now

Tianjin Estel Electronic Science and Technology Co.,Ltd

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

Generator Compartment Base Station Cabinet With Solar Controller / Solar Cell Panel

Country/Region china
City & Province shenzhen guangdong
Categories Mobile Phone Chargers
InquireNow

Product Details

 

Generator Compartment Base Station Cabinet With Solar Controller / Solar Cell Panel
 

Quick Details:

 

Place of Origin: Shenzhen, China (Mainland)

External Size: equipment and battery cabinet H*W*D 2400*1600*800mm

External Size: generator cabinet

H*W*D 1300*1600*1000mm

Brand Name: ESTEL

Structure: double wall, with insulation, sandwich structure.

Model Number: DDTE041

Cabinet Layout:three compartments

Product Name: Outdoor Integrated Telecom Cabinet

Cabinet Lock: anti-theft three point lock
Certification: ISO9001, CE, 3C, FCC, TLC, IP55

Protection Level: IP55

Application: outdoor telecom base stationCable Entry: at cabinet bottom
Material: galvanized steelIllumination: DC48V LED lamp

Heat Insulation: PEF

Grounding Protection: copper bar

Color: grey (support custom made)

Cooling: AC220V Air Conditioner

Coating: anti-corrosion outdoor powder coating

Accessories Options: PDU, UPS, solar controller

 

Payment & Shipping Terms:

 

Minimum Order Quantity:1 set
Price:negotiation
Payment Terms:L/C,D/A,T/T, Western Union, Paypal, etc
Supply Ability:5,500 sets per month
Delivery Time:15-20 working days
Packaging Details:wooden case

 

1. Specifications

(1) Technical Parameters

 

ItemTypeTechnical Parameter
StructureDimension

External Size: equipment and battery cabinet

H*W*D 2400*1600*800mm.

External Size: generator cabinet

H*W*D 1300*1600*1000mm.

LayoutThree compartments
Equipment Installation Method19” standard rack battery shelf
Door

Equipment and battery cabinet includes two front door;generator cabinet includes one front door

with anti-theft three point lock for outdoor cabinet (support padlock)

Material

1.Galvanized steel;

2.Double walls, thickness of outer plate: 1.5mm, thickness of inner plate: 0.8mm, with heat insulation between two walls.

StructureAssembled
Ingress Protection

Equipment compartment, battery compartment: IP55

Generator compartment: IP45

Temperature ControlCooling

1500W, AC220V air conditioner

500W, AC220V air conditioner

Power SupplyGenerator Power Supply80hours
Battery backup power supply18hours
ProtectionIngress Protection

Equipment compartment, battery compartment: IP55

Generator compartment: IP45

LightingLED lamp48V LED lamp
TemperatureTemperatureWorking Temperature: -40°C ~ +55°C
Storage Temperature: -50°C ~ + 70°C
Transport Temperature: -50°C ~ +70°C
HumidityRelative Humidity5% ~ 100%
PressureAir Pressure62kpa ~ 101kpa (similar to 0m ~ 5000m altitude)
Radiation IntensitySolar Radiation Intensity1124 × (1±5%)W/m2

 

(2) Accessories List

 

NO.ItemQuantitySpecs
1Solar Cell Panel, Bracket111200W
2UPS 113KW
3Iron Lithium Battery148V700Ah
4Solar Controller148V250A
5Generator1Single Phase, 20KW
6AC&DC PDU1

Grade B Lightening Protection,

5-way DC input,

2- way AC output

7Cabinet 1 (Equipment Compartment + Battery Compartment)1

1. The Cabinet includes two compartments (separated left compartment and right compartment), with front door.

2. The external dimension of the cabinet is H×W×D 2400×1600×800mm.

3. Structure: Integrated splicing, with 20mm heat insulation cotton, including inner panel; Base: 2.0mm galvanized steel, cabinet: 1.5mm galvanized steel.

8Cabinet 2 (Generator Compartment)1

1. The cabinet includes one compartment, with front door.

2. The external dimension of the cabinet is H*W*D 1300*1600*1000mm.

3. Structure: Integrated splicing; without heat insulation cotton; Base: 2.0mm galvanized steel, cabinet: 1.5mm galvanized steel.

9AC air conditioner 11Cooling: 1.5KW, Power Consumption: 550W, AC230V
10AC air conditioner 21Cooling: 500W, Power Consumption: 250W, AC230V

 

2. Application

 

1. This solution is designed for remote area without AC mains power. It uses solar + generator power supply, and uses batteries as energy storage component.

Note:

2. The batteries charge and discharge frequency is high, so we recommend to use Iron Lithium Battery. The advantages of Iron Lithium Batteries are: anti - high temperature (up to 55°C), high battery cycle times, deep discharge, large current charge.

3. About the air conditioner, we recommend to use AC air conditioner, which is with high cost performance ratio.

 

3. Working Principle

 

  • In case of the solar cell panel working normally:
  • During the daytime, the solar power provide power supply for load and battery charge; In the nighttime, the batteries discharge and supply power for the load.
  • We assume the standard sunshine intensity is 6 hours in the area, the batteries working time is 24 - 6 = 18 hours.
  • In case of cloudy and rainy days, without sunlight:
  • The batteries discharge; when the batteries voltage is lower than 44V, the UPS will send switch signals and start the generator, then the generator will start to provide power supply for batteries and load.
  • When the batteries voltage is restored to 53.5V, the generator will be turned off.

 

System Principle Diagram:

 

 

4. Layout Pictures

 

 

5. Description

5.1Cabinet Door and Lock

 

The cabinet door uses embedded structure. The door opening angle is larger than 110°and the door limit device can limit the opening angle. The lock is theftproof three point lock, supporting padlock.

 

5.2. Door lock theft proof design

 

  • Damage resistance of the theft proof lock meets GA/T 73-1994 “Mechanical Anti-theft Lock” class B requirement, supporting padlock.

 

 

  • Three point lock

 

5.3 Cable Inlet

Feeder cable and other external cables all use bottom wiring method.

 

 

5.4 Grounding Protection

 

  • The cabinet includes grounding copper bar with anti-corrosion coating. There are enough screws for wiring connection terminals.
  • The metal part of the cabinet should be interconnected and be connected with grounding bar. Connection resistance between any two points is lower than 0.1Ω.
  • Protective earthing of other equipments inside the cabinet should be connected to the grounding bar.

 

5.5 Connection and Fastening

 

  • Use anti-loose threaded connection as structure and bearer connection. Anchor bolt for fixing cabinet use hot dip galvanized bolts.
  • Door hinges use inner hinge mode.

 

 

5.6 Appearance and Surface Treatment

 

Cabinet surface coating is outdoor special powder coating, with white gray color (PANTONE 428C). The coating complies with GB/T 3181-2008 requirement.

 

6. Packing and Shipping

 

 

Our Delivery Agent

 

The goods can be shipped by sea, by air, by courier, by land, by train, etc.

Besides the following delivery agent, we can also look for the delivery agent with the best price in china if you need us to do for you.

 

7. Our Contact Information

 

Mobile Phone: 0086-13752765943

Telephone: 0086-0755 66600941

Email: info@estel.com.cn

           lxf.estel@hotmail.com
Skype: fiona.liang10

Hot Products

19 Inch Double Wall Green Outdoor Telecom Cabinet For Wireless Communication Base Station 1. ...
Small Size Outdoor Telecom Equipment Cabinets Customized Sheet Metal Box With Heat Exchanger 1. ...
Stainless Steel Outdoor Telecom Cabinet With Cooling System / Air Conditioner Type Telecom Enclosure ...
Temperature Control Custom-Made Outdoor Telecom Cabinet With Front Door And Back Door Antitheft 1. ...
Weather Proof Galvanized Steel Outdoor Equipment Cabinet With Front Door and Rear Door For Base ...
5G 19 Inch Data Rack 32U For CCTV Security Systems 750x750x1750mm 1. Application This series cabinet ...