Quick Details:

 

Place of Origin: Shenzhen, China (Mainland)Cooling Capacity : 100W
Brand Name: ESTELHeating Capacity: 300W
Model Number: TE06-10TEH/01Dimension H×W×D: 281×185×180mm
Product Name: Thermoelectric (Peltier) Air ConditionerInput Voltage: DC48V
Certification: ISO9001, CE, 3C, FCC, TLCCooling Start Current: 5.5A
Cover Material: galvanized steelCooling Stable Current: 4.5A±10%
Color: greyWorking Temperature: -20°C ~ +55°C
IP Grade: IP55Noise: 55dB
Installation Mode: door mountedCooling Method: peltier

 

Payment & Shipping Terms:

 

Minimum Order Quantity:1 set
Price:Depend on order quantity
Payment Terms:L/C,D/A,T/T, Western Union, Paypal, etc
Supply Ability:1,500 sets per month
Delivery Time:7-10 working days
Packaging Details:carton + foam + wooden case+pallet

 

1. Specifications

(1) Technical Parameters

 

Model No.TC06-10TEH/01
Cooling Methodair to air
Cooling Objectair
Cooling Object Contact Mediumair
Rated Cooling Capacity100W
Rated Heating Capacity300W
Rated Input VoltageDC48V (43V~58V)
Cooling Stable Current4.5A±10%
Cooling Start Current5.5A
Operating Environmental Temperature-20°C-55°C
Overheat ProtectionCan be set
Installation Modeside
Noise55dB
Service Lifeover 7 years
Size (HxWxD)281x185x180mm
Weight6Kg

 

 

Dimension Diagram: H×W×D: 281×185×180m



2. Description
 
The TE06-10TEH/01 TEC air conditioner is a full automation temperature control device. It uses intelligent controller to control the whole system of the air conditioner. According to the variation of environment temperature, the intelligent controller can automatically detect and operate.
 
The TE06-10TEH/01 TEC air conditioner consists of 6 parts: peltier module (including sealing and insulation material), cold end radiator, hot end radiator, cold end fan, hot end fan, monitoring module. When power supply is connected to the TEC, one side of the peltier conduct cooling, and the other side of the peltier conduct heating, the cool (heat) from which will diffuse to the surrounding environment through cold (hot) end radiators and fans. The cold end radiator and cod end fan constitute the inside circulation for cooling the cabinet internal environment, while the hot end radiator and hot end fan constitute outside circulation for heat radiation to the external environment.



TE06-10TEH/01 inside circulation and outside circulation air ventilation
Both the inside circulation and outside circulation air ducts adopt air inlet through middle fans and air outlet through radiators at the two sides.
3. Application
The Thermoelectric Cooler (Peltier Air Conditioner) is widely applied in outdoor telecom cabinet, small and medium sized telecom room, UPS room, outdoor base station room, etc.
4. Control

4.1 Application

 
 
TE06-10TEH/01 air conditioner uses a universal intelligent controller ET724, which is controlled by highly integrated STC single chip microcomputer. The controller, with good performance, easy and convenient installation and set, is widely applied in small and medium sized telecom room, UPS room, outdoor base station room, etc.
 

 

4.2 Technical Parameter

 

  • Three digit seven segment digital tube displays measured temperature and set temperature.
  • Temperature measurement accuracy: 0.1 °C; display accuracy: 0.1 °C.
  • Intelligently choose cooling mode or heating mode.
  • With protective direct ventilation function.
  • Power Supply: DC48V.
  • Power Consumption: ≤5W.
  • Working Environment: -30°C~70°C; <90%RH.
  • Installation method: guide rail, hanging.
  • Size (L×W×H): 150mm×190mm×45mm

 

4.3 Operating Instruction

 
 
ET724 uses user-friendly interfaces, which can be operated easily. All the operations can be realized with four buttons. The following is the control board diagram:
 
 

 

 

5. Wiring Diagram

 

8. Packing and Shipping
 

 
Our Delivery Agent
 
The goods can be shipped by sea, by air, by courier, by land, by train, etc.
Besides the following delivery agent, we can also look for the delivery agent with the best price in china if you need us to do for you.
 
9. Our Contact Information
 
Mobile Phone: 0086-13752765943
Telephone: 0086-0755 66600941

Email: info@estel.com.cn

           lxf.estel@hotmail.com
Skype: fiona.liang10

Hot Products

19 Inch Double Wall Green Outdoor Telecom Cabinet For Wireless Communication Base Station 1. ...
Small Size Outdoor Telecom Equipment Cabinets Customized Sheet Metal Box With Heat Exchanger 1. ...
Stainless Steel Outdoor Telecom Cabinet With Cooling System / Air Conditioner Type Telecom Enclosure ...
Temperature Control Custom-Made Outdoor Telecom Cabinet With Front Door And Back Door Antitheft 1. ...
Weather Proof Galvanized Steel Outdoor Equipment Cabinet With Front Door and Rear Door For Base ...
5G 19 Inch Data Rack 32U For CCTV Security Systems 750x750x1750mm 1. Application This series cabinet ...