High Efficiency HFO Fired Power Plant Open Type 3 Phase Generator Set

 

 

Descrition:

 

Utilities and Independent power producers use our 0~60 MW power plants to generate power to the grids in the undeveloped, developing world and in remote areas. These plants are flexible to follow the actual load and produce the necessary electricity typically from diesel oil, heavy fuel oil, bio diesel and bi-fuel. High efficiency, low emissions and proven long-term reliability make our diesel oil power plants, heavy fuel oil power plant, and bi-fuel power plants suitable for baseload applications. Depending on your current load profile, ambient conditions and what fuel is available (diesel oil, heavy fuel oil, crude oil etc.) we make sure you will get the most productive and cost-effective solution

Our company offers a wide range of engines for stationary power generation, where their competitive first-cost, high energy efficiencies and low life-cycle costs underwrite success, ranges from baseload power plant, peaking power plant to industrial self-captive power plant in cement, textile, mining or oil and gas industries etc.

These engines comfortably meet current emission standards, and are able to comply with more strict national codes by adding emission reduction equipment.

 

 

Peaking power plant

 

Our power plants can start and ramp up to full load very rapidly, in less than minutes. They can start upon a grid or a large power plant after shut down, without any external input of energy. Due to very high simple cycle efficiency on part and full load, they can provide very competitive power regulation and spinning reserve services to large grids, which both require operation on partial load. These very same plants can be used for peaking services during peak electricity demand hours. Due to the high efficiencies and consequential low generation costs, our power plants create more revenues for its operators. The main fuel can be gas, LFO, HFO or a multi-fuel combination of these.

 

 

Competitive Advantage:

 

Our experts in application engineering and project management are the key to achieving very short construction times , builds turn-key power plant with an output up to 60MW as base load power plant, peaking power plant or industrial self-captive power plant in cement, textile, mining or oil and gas industries etc. The power fuel can be diesel oil, bio-diesel, heavy fuel oil (HFO) or bi-fuel

 

 

 

Industrial self-captive power plant

 

Many energy intensive industries find it attractive to improve their competitiveness by producing their energy in a local captive power plant and thereby reduce the energy costs. In some areas this improves also the availability of energy due to unstable grid conditions. Many of the industrial power plants operate, producing electricity and utilizing the waste heat of the generation process to produce steam, hot water and cooling. All this we can do for you.

 

 

Applications:

 

cement, textile, mining or oil and gas industries etc.

 

G300 Statinary Generating Sets Main Specification
Model1000GF11250GF31350GF41400GF4
Rated power, KW1000125013501400
Overload , KW1100137514851540
Rated voltage, V400/415/440/3300/6300/10500/13800
Rated current , A        
Frequency , Hz5060506050605060
Power factor0.8 Lagging
Phase3
Diesel engineG6300ZD6G6300ZD8G8300ZD6G6300ZD10G8300ZD10G8300ZD8G8300ZD10G8300ZD8
Rated power, KW11031470147114711765200017652000
Rated rev, rpm500600500600500600500600
Alternator3 phase alternator
voltage fluctuation rate%<0.5<0.5
Frequency fluctuation rate, %<0.5<0.5
Stable voltage regulating rate, %±1.0±1.0
Transient voltage regulating rate, %+20, -15+20, -15
Stable Frequency fluctuation rate, %<3<0.5
Transient frequency regulating rate, %+12, -10
Stablizing time, voltage , S<4
Stablizing time, frequency , S<3
voltage regulating methodautomatic and munual
Frequency regulating methodmanual
starting methodcompressed air
Lubricating methodpressue lubricating 
Cooking methodwater cooling
couplingflexible
Overdimension, mm3880*2150*31808470*2360*3060
Weight, Kg300003500038000
G300 Statinary Generating Sets Main Specification
1500GF61600GF51800GF72000GF8
1500160018002000
1650176019802200
400/415/440/3300/6300/10500/13800
        
5060506050605060
0.8 Lagging
3
G8300ZD10G8300ZD8G8300ZD10G8300ZD8G8300ZD8G8300ZD8G8300ZD12G8300ZD8
17652000176520002000200022062000
500600500600600600600600
3 phase alternator
<0.5
<0.5
±1.0
20, -15
<0.5
+20, -15
<5
<4
automatic and munual
manual
compressed air
pressue lubricating 
water cooling
flexible
8470*2360*3060
3800042560

 

 

Remark

1. the generator voltage and frequency can be selected

2. rating for the generator set is based on the following standard conditions

air temperature :25℃

total barometric pressure 100kpa

charge air coolant temperature 25℃

relative humidity 30%

If test ambient conditions are not same as the standard ambient conditions, the power and fuel consumptions should be revised according to GB/T6072.1-2000

3. The generator set can operate under overload, intermittently for 1 hour every 12h, the fuel injection quantity is usualy locked in the rated power position

 

GN8320 Stationary Generating Sets Main Specification

Model

2400GF

2500GF

Rated power, KW

2400

2500

Overload , KW

2640

2750

Rated voltage, V

400

415

3300

6300

10500

400

415

3300

6300

10500

Rated current , A

4330

4174

525

275

165

4511

4348

547

172

286

Frequency , Hz

50

50

Power factor

0.8 Lagging

0.8 Lagging

Phase

3

3

Diesel engine

GN832000ZD

GN8320ZD

Rated power, KW

2648

2795

Rated rev, rpm

750

750

Alternator

3 phase alternator

voltage fluctuation rate%

±1.0

Frequency fluctuation rate, %

+12, -10

Stable voltage regulating rate, %

3

Transient voltage regulating rate, %

+12, -10

Stable Frequency fluctuation rate, %

4

 

Transient frequency regulating rate, %

5

Stabilizing time, voltage , S

+1

Stabilizing time, frequency , S

+12, -10

voltage regulating method

automatic and manual

Frequency regulating method

manual

starting method

compressed air

Lubricating method

pressure lubricating

Cooking method

water cooling

coupling

flexible

Overdimension, mm

8950*2570*6050

Weight, Kg

45000

 

 

Remark

 

1. the generator voltage and frequency can be selected

2. rating for the generator set is based on the following standard conditions

air temperature :25℃

total barometric pressure

charge air coolant temperature

relative humidity

If test ambient conditions are not same as the standard ambient conditions, the power and fuel consumptions should be revised according to GB/T6072.1-2000

3. The generator set can operate under overload, intermittently for 1 hour every 12h, the fuel injection quantity is usualy locked in the rated power position

 

Hot Products

LW250-720 Solid Bowl Delaval Oil Purifier Machine For Organic Chemicals 1. Solid bowl decanter ...
Stainless Steel 316 Minerals Centrifugal Oil Purifier , Oil Water Centrifugal Separator 1. Solid ...
Heavy fuel oil diesel lubrication Oil Purifier Separator Self Cleaning 50Hz / 60Hz 1000-30000L/H ...
Professional stainless steel 2250RPM - 4000RPM Industrial oil and water Decanter Centrifuge Oil and ...
Marine vessel and industry Fuel Oil Purifiers disc centrifuge purifier Separator Stainless Steel ...
Small Centrifugal Oil Purifier Water Fuel Filter Separator Variable Discharging 500 - 1000 L/H 1. ...