Home Companies Advanced Instruments Co.,Ltd

Classic 3100 Binary HPLC Lab System with UV/VIS and Refractive Index Detector

Advanced Instruments Co.,Ltd
Active Member

Contact Us

[China] country

Address: Hi-tech Developing Industrial Area, Liuyang City,Changsha,Hunan Province,China 

Contact name:Sandy

Inquir Now

Advanced Instruments Co.,Ltd

Classic 3100 Binary HPLC Lab System with UV/VIS and Refractive Index Detector

Country/Region china
City & Province changsha hunan
Categories Solar Chargers
InquireNow

Product Details

 

Eclassical 3100 Binary HPLC System 

 

 

P3100 High Pressure Constant Flow Pump
◆ Flow rate range: 0.001-10.000 mL/min, in 0.001 mL increments
◆ Flow accuracy: ≤±0.2% (1.00ml/min, H2O,R.T.,8.5MPa)
◆ Flow precision: RSD≤0.06% (1.00ml/min, H2O,R.T.,8.5MPa)
◆ Maximum pressure: 45MPa

 

 

UV3100 UV/VIS Detector

Wavelength range190-700 nm
Wavelength repeatability≤0.1 nm
Wavelength accuracy≤±1.0 nm
Bandwidth8nm
Response time0.0 s-5 s
Baseline noise≤±0.5×10-5 AU
Drift≤1.0×10-4 AU/h (empty cell, 254 nm, 60 min)
Path length10 mm(analytical cell)
Light sourcwDeuterium Lamp

 

 

Chromsoft Chromatographic Data-processing Workstation

◆ Internal and external standard calculation methods
◆ Automatically displays, prints, exports and starts other programs after the completion of a measurement.
◆ Comply with the requirements of the 21 CFR Part 11 directive of the FDA

 

 

Eclassical 3100 System Kits

◆ Containing required tubing, fittings, wreches and cables for system.
◆ C18 column 5μm ID4.6×200mm
◆ 7725i manual injector
◆ TD-1-15 mixer
◆ User manual

 

 

RI-201H Refractive Index Detector

◆ Flow cell type:2 chamber-type
◆ Measuring method:Deflection type
◆ Refractive Index range:1.00 to 1.75
◆ Measuring range:0.25 to 512μRIU
◆ Drift:0.2μRIU/h (Pure water 1mL/min, PURGE OFF)
◆ Linearity range:≥600μRIU
◆ Noise:≤2.5nRIU (Pure water, response : 1.5sec)
◆ Response:0.1 , 0.25 , 0.5 , 1 , 1.5 , 2 , 3 , 6 sec
◆Cell volume:8μL
◆Flow rate:(Usual) 0.2 to 3.0mL/min;(Max.) 10mL/min (solvent: pure water)

 

 

Hot Products

Sulfur Content Tester Lamp Method Summary The sulphur content tester is designed and made as per the ...
Sulfur Content Test Apparatus (Quartz Tube Method) Summary The working principle:burn the sample in ...
ASTM D482 Petroleum Products Ash Content Tester Introduction The ash content test equipment is ...
ASTM D92 Cleveland Open Cup Flash Point Apapratus Introduction This cleveland flash point Apparatus ...
Fully Automatic Cleveland Open Cup Flash Point Analyzer Introduction According to test method of GB...
Lubricating Grease Dropping Point Tester Apparatus Introduction The Dropping Point Testser is ...