Home Companies Advanced Instruments Co.,Ltd

30KV Very Low Frequency (VLF) Cable Testing Equipment Made in China

Advanced Instruments Co.,Ltd
Active Member

Contact Us

[China] country

Address: Hi-tech Developing Industrial Area, Liuyang City,Changsha,Hunan Province,China 

Contact name:Sandy

Inquir Now

Advanced Instruments Co.,Ltd

30KV Very Low Frequency (VLF) Cable Testing Equipment Made in China

Country/Region china
City & Province changsha hunan
Categories Other Roadway Products
InquireNow

Product Details

 

30KV Very Low Frequency (VLF) Testing Equipment

 

 

I. Introduction:

The VLF testing equipment is suitable for testing cables, transformers, switchgear, Rotating machinery, and other Electrical apparatus

 

 

II. Functions

1. Fully automatic microcontroller makes the vlf testing equipment easy to operature.
2. Built-in printer is designed with this equipment
3. True sine wave output 
4. Real-time display of actual output waveform is available.
5. Ergonomic, menu guided, large backlit LCD
6. Storage of test results for later retrieval and print.
7. Over voltage and current protected
8. Variable frequency 0.1Hz, 0.05Hz, 0.02 Hz
9. Data of current, voltage and waveform directly sampled at HV side.
10. AC testing does not degrade good cable insulation
11. Harmful space charges are not injected into the cable insulation
12. No traveling waves are generated during testing
13. Rugged and reliable design less prone to failure from transients

 

 

III.Safety Feature

  • Short circuit protected.
  • Status display of all important safety functions and messages.
  • Safe, easy to use operation with emergency off and key switch lock-out.
  • Fully integrated discharge circuit to safely ground the DUT after testing.
  • Zero start interlock.
  • Zero voltage switching.

 

IV. Specifications:

1. Input: 220 ± 10% Volts AC, 50/60 Hz, single phase.
2. Output-Voltage. 30KV
3. Output frequency: 0.1Hz, 0.05Hz, 0.02Hz.
4. Stability of frequency: Fluctuation < 0.5%
5. Measurement accuracy: ± 3%.
6. Positive and negative voltage peak errors: ≤ 3%.
7. Voltage waveform distortion: ≤ 5%
8. Construction: In two units: Controller and Booster.
9. Ambient conditions of use: Temperature Indoor and outdoor: -10ºC to + 50ºC.
10. Humidity: ≤ 85%

 

ModelRated Voltage/current

Load Carrying

Capacity

Power fuseProduct Structure and Weight
30

30kV/20mA

(Peak)

0.1Hz,≤0.5µF~1.1µF5A

Controller:4kg

Booster: 25kg

0.05Hz,≤0.5µF~2.2µF
0.02Hz,≤0.5µF~5.5µF
50

50kV/30mA

(Peak)

0.1Hz,≤0.5µF~1.1µF7A

Controller:4kg

Booster: 50kg

0.05Hz,≤0.5µF~2.2µF
0.02Hz,≤0.5µF~5.5µF
60

60kV/30mA

(Peak)

0.1Hz,≤0.5µF9A

Controller:4kg

Booster Grade 1(30kV):25kg

Booster Grade 2(30kV):25kg

0.05Hz,≤0.5µF~1µF
0.02Hz,≤0.5µF~2.5µF
80

80kV/30mA

(Peak)

0.1Hz,≤0.5µF12A

Controller:4kg

Booster Grade 1(30kV):25kg

Booster Grade 2(50kV):50kg

0.05Hz,≤0.5µF~1µF
0.02Hz,≤0.5µF~2.5µF

 

 


Picture of 30KV Very Low Frequency (VLF) Cable Testing Equipment

 

 

Hot Products

Introduction This 4 ball test machine uses four Ф12.7mm standard steel balls evaluate the load...
ASTM D6371 Cold Filter Plugging Point Apparatus CFPP Tester Introduction Using method: cool the ...
Portable Infrared Oil Content in Water Analyzer Introduction AIC-7 portable infrared oil content ...
FTIR Fourier Transform Infrared Spectroscopy Introduction AIC-650G is a single beam FTIR spectromete...
Ramsbottom Method Carbon Residue Tester Introduction This Ramsbottom Carbon Residue Tester is mainly ...
Ferrous Wear Concentration versus PQ Index Wear Debris Tester Introduction This PQ analyzer aims at ...