Home Companies Chongqing HLA Mechanical Equipment Co., Ltd.

EE36 Portable Oil Testing Equipment / On Line Humidity Transmitter

Chongqing HLA Mechanical Equipment Co., Ltd.

Contact Us

[China] country

Trade Verify

Address: No.94, North Road of College Town, Shapingpa District, Chongqing, China

Contact name:Kevin

Inquir Now

Chongqing HLA Mechanical Equipment Co., Ltd.

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

EE36 Portable Oil Testing Equipment / On Line Humidity Transmitter

Country/Region china
City & Province chongqing chongqing
InquireNow

Product Details

EE36 Portable Oil Testing Equipment / On Line Humidity Transmitter

 

Description:

Transmitter Series EE36 are specially designed for the measurement of water content in oil, it can be portable or online use. They are certified in accordance with the regulations of the "Germanischen Lloyd (GL)" and therefore can be utilized in the maritime field as well. EE36 is ideal for online monitoring of moisture in lubrication or insulation oil after installing on equipments, which is very important for the long-term performance and adaptive maintenance of plant and machinery. For instance, moisture affects dramatically the insulation characteristics of electrical transformer oil and therefore continuous monitoring is extremely important.The modular housing enables a user-friendly operation and a quick replacement of the sensor unit for service purposes.The construction of the transmitter makes field and local loop calibration an easy task.

EE36 is dedicated for the accurate and reliable measurement of moisture in lubrication oil in maritime applications and is certified according to the “Germanischer Lloyd (DNV GL)”. The device is specifically approved for use in MAN B&W marine diesel engines for instance.

 

The outstanding long-term stability and resistance to pollution of the EE36 rests on the high-end E+E capacitive sensing element of the HC series.

 

Humidity measurement in oil:

The monitoring of the moisture in lubrication oil is of paramount importance for the long-term performance and predictive maintenance of the machinery. The moisture in oil is described by either the absolute value “water content” x (ppm) or the relative value “water activity” aw:

 

0The water content x (ppm) represents the ratio between the mass of water and the mass of oil.

0The water activity aw is the ratio between the actual moisture content and the maximal moisture content of the saturated oil.

aw = 0 corresponds to completely dry oil, while aw = 1 means a fully saturated oil.

 

EE36 measures the water activity (aw) and the temperature (T) and calculates out of them the water content x. The accu-rate calculation of the water content of a certain oil requires a set of oil specific parameters.

 

The measured and the calculated values are available on two free scalable and configurable analogue outputs as well as on the optional display. Additionally, EE36 can be fitted with a relay module for alarms and process control purposes.

 

Installation:

The sensing probe of EE36 is designed for continuous online monitoring. In addition to the fix installation, the use of a ball valve allows for insertion and removal of the probe without process interruption.

 

Easy Adjustment:

The user can easily readjust the transmitter by using either a simple procedure with two push buttons on the printed circuit board or the free configuration software.

 

Product Configuration Software (EE-PCS):

The free configuration software (download at www.epluse.com) allows for easy setup of the analogue and alarm outputs, as well as for the adjustment of the water activity and temperature readings. Furthermore, the EE-PCS facilitate the replacement of the sensing element or of the sensing probe.

 

Features of EE36:

1. Measurement of aw and T at pressure up to 20 bar (300 psi) P

2. Calculation of water content in ppm P

3. Two free scaleable and configurable analogue outputs P

4. Probe cable length up to 20 m (66 ft) P

5. Easy on site adjustment and calibration of aw and T outputs P

6. LED indication for operation and sensing probe status P

7. User configuration of the instrument with PC via RS232 interface P

8. Configuration software P

9. Display of aw, T and water content with MIN/MAX function (optional)

10. Two free configurable relays outputs (optional)

11. Pluggable sensing probe (optional)

12. Connector for power supply and outputs (optional)

 

Technical Data

Measuring values:

Water activity
SensorHC1000-400
Measuring range0...1aw
Accuracy(including hysteresis, non-linearity and repeatability, traceable to intern. standards, administrated by NISTPTB, BEV...)
-15...40 °C (5...104 °F) ≤0.9 aw ± (0.013 + 0.3%*mv) aw
-15...40 °C (5...104 °F) >0.9 aw ± 0.023 aw
-25...70 °C (-13...158 °F) ± (0.014 + 1%*mv) aw
-40...180 °C (-40...356 °F) ± (0.015 + 1.5%*mv) aw
Temperature dependence of electronicstyp. ± 0.0001 [1/°C] (typ. ± 5.6 * 10-5 [1/°F])
Temperature dependence of sensing probetyp. ± (0.00002 + 0.0002 x aw) x ∆T [°C] ∆T = T - 20 °C
Response time with stainless steel filter at 20 °C (68 °F) / t90typ. 10 min in still oil
Temperature
Temperature sensor elementPt1000 (tolerance class A, DIN EN 60751)
Working range sensing probe-40...180 °C (-40...356 °F)
Temperature dependence of electronicstyp. ± 0.005 °C/°C

 

Outputs:

Two freely selectable and scaleable analogue outputs0 - 5 V -1 mA < IL < 1 mA
0 - 10 V -1 mA < IL < 1 mA
4 - 20 mA RL < 500 Ohm
0 - 20 mA RL < 500 Ohm

 

Adjustable measurement range:

Water activity aw0~1
Temperature T-40~180°C (-40~356°F)
Water content x0~100000ppm

 

General:

Supply voltage

8...35 V DC

12...30 V AC (optional 100...240 V AC, 50/60 Hz)

Current consumption - 2x voltage outputfor 24V DC/AC: typ. 40 mA
Current consumption- 2x current outputfor 24V DC/AC: typ. 80 mA
Pressure range sensing probe0.01...20 bar (0.15...300 psi)
System requirements for softwareWINDOWS 2000 or later; serial interface
Serial interface for configurationRS232C
RS232CAl Si 9 Cu 3 / IP65 / Nema 4
Cable glandM16 x 1.5 cable Ø 4.5 - 10 mm (0.18 - 0.39”)
Electrical connectionscrew terminals up to max. 1.5 mm² (AWG 16)
Sensor protectionstainless steel filter
Operating temperature range of electronics-40...60 °C (-40...140 °F)
Working and storage temperature range
Housing with display-20...50 °C (-4...122 °F)
Storage temperature-40...60 °C (-40...140 °F)
Electromagnetic compatibility according to

EN61326-1 EN61326-2-3 ICES-003 ClassB

Industrial Environment FCC Part15 ClassB

DNV GL-CertificationEnvironmental Category D

 

Options:

Displaygraphical LCD (128x32 pixels), with integrated push-buttons for selecting parameters and MIN/MAX function
Alarm outputs2 x 1 switch contact: 250 V AC / 6 A and 28 V DC / 6A threshold + hysteresis can be adjusted with configuration software
Switching parameters (freely selectableaw Water activity
T Temperature
X Water content

1) refer to the working range of the humidity sensor.

2) can be easily changed by software

3) ppm output is valid in the range 0...100°C (32...212°F)

4) no data output

*) The accuracy statement includes the uncertainty of the factory calibration with an enhancement factor k=2 (2-times standard deviation). The accuracy was calculated in accordance with EA-4/02 and with regard to GUM (Guide to the Expression of Uncertainty in Measurement).

Hot Products

Fully Automatic High Voltage Transformer Vacuum Oil Purifier Machine Remove The Oil Water,Particles ...
China Industrial Safety Vacuum Transformer Oil Purifier Oil Centrifuging Machine DVP Application: ...
Lubrcating Oil Transformer Oil Testing Equipment On Line Moisture Testing Machine Description: E+E ...
EE364 On Line Moisture Transmitter , Oil Water Content Testing Equipment Description: The EE364 is ...
ZJY Insulating Oil Dielectric Strength Test Equipment 80KV / 100KV Light Weight Application: ZJY ...
BDV 100KV Transformer Oil Testing Equipment For Dielectric Strength Application: ZJY automatic oil ...