Access Traffic Optical Bypass Switch Network TAP Multimode Optical Protection Link

Country/Region china
City & Province chengdu sichuan
Categories Other Switches
InquireNow

Product Details

Access Traffic Optical Bypass Switch Network TAP Multimode Optical Protection Link

 

1.Overviews

With the rapid development of the Internet, the threat of network information security is becoming more and more serious, so a variety of information security protection applications are used more and more widely. Whether it is traditional access control equipment (firewall) or a new type of more advanced protection means such as intrusion prevention system (IPS),Unified threat management platform (UTM), Anti-denial service attack system (Anti-DDoS), Anti-spam Gateway, Unified DPI Traffic Identification and Control System, and many security devices are deployed in series in the network key nodes, the implementation of the corresponding data security policy to identify and deal with legal / illegal traffic. At the same time, however, the computer network will generate a large network delay or even network disruption in the case of fail over, maintenance, upgrade, equipment replacement and so on in a highly reliable production network application environment, users cannot stand it.

 

2.Intelligent Bypass Swtich Application Solution​

Link Series Device Protection

 

 

                                                              Figure 1: Policy Traffic Traction Protector Bypass Switch Data Flow

 

As shown in Figures 1, the NetTAP® "Policy Traffic Traction Protector" is deployed in series between network devices (routers, switches, etc.), and the data flow between network devices no longer leads directly to IPS / FW, NetTAP® "policy traction protector" to IPS / FW, when the IPS / FW due to overload, crash, software updates, policy updates and other conditions of failure, the "bypass switch" through intelligent heartbeat message detection Function of the timely discovery, and thus skip the faulty device, without interrupting the premise of the network, the rapid network equipment directly connected to protect the normal communication network; when the IPS / FW failure recovery, but also through intelligent heartbeat packets Detection of timely detection of the function, the original link to restore the security of enterprise network security checks.

NetTAP® "Bypass switch" has a powerful intelligent heartbeat message detection function, the user can customize the heartbeat interval and the maximum number of retries, through a custom heartbeat message on the IPS / FW for health testing, such as send the heartbeat check message to the upstream / downstream port of IPS / FW, and then receive from the upstream / downstream port of IPS / FW, and judge whether the IPS / FW is working normally by sending and receiving the heartbeat message.

 

3. Bypass Switch Bypass TAP Technical Characteristics

SpecFlow/FullLink Protection

The NetTAP® "INLINE Network Security Bypass Swtich based on Network TAP Strategic Traffic Protector" supports serial protection for complete link traffic and a serial protection mode for a specific traffic type. Users can choose the appropriate deployment mode according to the deployment requirements of different security devices.

FullLink protection mode. In this mode, the Policy Traffic Traction Protector forwards all traffic from the deployed link to the security device and performs real-time monitoring of the state of the security device. If the status of the security device is abnormal, the protector will automatically switch to the bypass state ensures network availability.

SepcFlow protection mode. In this mode, the Policy Traffic Traction Protector forwards some of the user-specified traffic types in the deployment link to the security device for processing. The remaining traffic is automatically bypassed without passing through the security device. While the protector on the state of the safety device to perform real-time monitoring, once the safety device status is abnormal, the protector will automatically switch to bypass state to ensure the availability of the network.

 

Speed BYPASS switch

The NetTAP® policy traffic traction protector has a very low switching latency to minimize the impact the user network has during the handover process. NetTAP® Policy Traction Protector the switchover duration is <50ms and the NetTAP® policy traffic traction protector has an optical port switching duration of <8ms. In the case of a security device failure, the NetTAP® policy traffic traction protector performs a failure state switch that the user has almost no effect on the network.

 

4. Bypass Switch Bypass TAP Technical Specifications

Product modelSpecifications
NT-FBYP-L1X-SR1U chassis, 1*10GE multimode optical protection link
NT-FBYP-L1X-LR1U chassis, 1*10GE single-mode optical protection link
NT-FBYP-L1G-SX1U chassis, 1*GE multi-mode optical protection link
NT-FBYP-L1G-LX1U chassis, 1*GE single mode optical protection link
NT-CBYP-L1G1U chassis, 1*GE electrical protection link
NT-CBYP-L2G1U chassis, 2*GE electrical protection link
NT-FBYP-L2G-SX51U chassis, 2*GE multi-mode optical protection link
NT-FBYP-L2G-LX1U chassis, 2*GE single-mode optical protection link
NT-FCBYP-L4XG-SR1U chassis, 2*GE electrical protection link, 1*GE multi-mode optical protection link, 1*10GE multimode optical protection link
NT-FCBYP-L4XG-LR1U chassis, 2*GE electrical protection link, 1*GE single mode optical protection link, 1*10GE single mode optical protection link
 

1*10GE Optical BYPASS link(NT-FBYP-L1X-SR)

 

 

Product ModelNT-FBYP-L1X-SR Optical Bypass Network TAP
Interface formSFP + slot2 * SFP + interface, support 10 Gigabit optical / electrical modules
10G optical Bypass link1 link, 2 * 10Gbase-SR multimode interface

 

Deploy mode

Number of link protection linksMaximum support for a 10GE BYPASS link
Monitor1*10GE monitoring link (2 * SFP + slot), supported 10GBASE-LR/SR
Index parameterMulti-mode insertion loss1.1dB to 1.6dB
Multimode emission optical power-7.3dB to 1dB
Multimode receive optical power≥-12dB
Multimode operating wavelength850nm
Multimode transmission distance300M
Single mode short insertion loss1.1dB to 1.6dB
Single mode short distance emission optical power-6dB to 0.5dB
Single mode short distance receiving optical power≥-14dB
Single mode short working wavelength1310nm
Single mode short distance transmission distance10KM
Single mode mid - range insertion loss1.1dB to 1.6dB
Single mode mid - range emitting optical power-1dB to 3dB
Single mode mid - range received optical power≥-18dB
Single mode midpoint working wavelength1550nm
Single mode distance transmission distance40KM
Single mode long distance insertion loss1.1dB to 1.6dB
Single mode long distance emission optical power0dB to 4dB
Single mode long distance receiving optical power≥-24dB
Single mode long distance working wavelength1550nm
Single mode long distance transmission distance80KM
Functional performanceTotal number of interfaces4
Line speed processing capacity40Gbps
Cross - link protection based on IP / protocol / port quintuple specific trafficSupport
Based on the total flow of the series protectionSupport
Multi - channel load balancing function-
Custom heartbeat message functionSupport
Ethernet encapsulation supportSupport
BYPASS switching functionSupport
Bypass switch without flashSupport
CONSOLE network managementSupport
IP/WEB network managementSupport
SNMP V1/V2C network managementSupport
TELNET/SSH network managementSupport
SYSLOG protocolSupport
User authentication functionBased on user name and password authentication
ElectricRated supply voltageAC-220V/DC-48V【Optional】
Rated power frequency50HZ
Rated input currentAC-3A / DC-10A
Rated Power45W
EnvironmentWorking Temperature0-50℃
Storage temperature-20-70℃
Working humidity10%-95%,No condensation
User configurationconsole configurationRS232 interface,9600,8,N,1
Outside network management interface1*10/100/1000M Ethernet interface
Password authenticationSupport
DimensionChassis dimension(U)1U 485mm*44.5mm*350mm

 

NT-MBYP-CHS Bypass Switch.pdf 

Hot Products

10GE Data Acquisition and Packet Acquisition Network Visibility Network TAP 1.Overviews A full ...
Network TAP for Bank Data Center Network Visibility Traffic Monitoring and Business Awareness ...
Traffic Visibility NPB SDN Traffic Capture and Distribution from TAP or SPAN Port - Complete the ...
Traffic Visibility NPB SDN Traffic Capture and Distribution from TAP or SPAN Port -Complete the ...
Ethernet Network TAP Inline Monitoring with Intelligent Bypass for Network Security TAP(Test Access ...
Why do You Need a Network Packet Broker(NPB) to Keep Your Networks Safe? 1. Product Background The ...