Coating Thickness Gauge TG8832FN(film thickness gauge, paint thickness gauge)

TG8832FNdigitalcoating thickness gauge is using the magnetism and backset measuring thickness method .It can measure the thickness of the magnetism metal substrate (such as steel, iron, alloy and rigid magnetism steel and etc), non-magnetism cover layer (such as aluminium, chrome, copper, enamel, rubber, oil paint and etc) and non-magnetism metal substrate (such as copper, aluminium, zinc, tin and etc) and non-transmitting electricity cover layer (such as enamel, rubber, oil paint, plastic and etc). This instrument has small error of measure, excellent performance and good stability, easy operation and other characteristics, is a necessary measure instrument to control and guarantee the product quality, can be widely applied to manufacturing, metal processing industry, chemical industry, merchandise test fields.

Features

  • Precise measurements (2%+1)/(1%+1)
  • Quick measuring response and rapid measuring speed
  • Design of two independent parts , better applicability, stable measurement results
  • Strong data processing and analysis :5 types of Statistic value and histogram
  • 7 types of probes are available(F400, F1, F1/90°, N400, F10, N1, CN02), suitable to requirements of different customers
  • CTG Insight data processing platform , enable analysis and management of data

Technical Specification

Measuring range

F400 :0~400μm N400:0~400μm  F1:0~1250μm  F1/90:0~1250μm

N1:0~1250μm F10:0~10000μm  CN02:10~200μm

Measuring accuracy

F400, N400      1 point calibration:±(2%+0.7)2 point calibration:±(1%+7)F1, F1/90, N1, CN02  1 point calibration:±(2%+1)2 point calibration:±(1%+1)F10           1 point calibration:±(2%+10)               2 point calibration:±(1%+10)

Calibration

1 point calibration /2 point calibration /basic calibration

Display resolution

0.1um (0~99.9um) / 1um (Over 100um)

Weight

250g(including battery package )

Operation environment

Temperature: 0℃~50℃ humidity: 20%RH~90%RH

Operation mode

Direct testing mode and block statistics mode

Measuring mode

continuous/single

Shutdown mode

manual/automatic

Operation alarm

Ring music to alarm mistake

Signal Dealing

Threshold

Limits setting and automatically alarm measured values out of limit

Data analysis

Analyzing a batch of measuring values via histogram

Statistic function

Mean/ Standard deviation / Number of measurements/ Maximum/ Minimum

Data Merory

Thickness values

500 measuring data

Delete

Single doubtful data / All data of one group

Input/Output

Print

measured values, statistic values, limit values and histogram

Communication

RS232/USB

Power supply

Battery

9V Nickel-hydride/alkaline batteries

Power battery inspection

low voltage indication

Standard delivery

Main unit                

1  

Integrated probe ((N1orF1)

1

Calibration foil set

4

Calibration base set

1

9V alkaline battery

1

Instruction manual

1

Printer RD-E32-SN

1

Software  CTG Insight

1

Optional accessories

probe

F400   F1  F1/90° F10  N400  N1  CN02

Probe model

 

F400

F1

F1/90°

F10

N400

N1

CN02

 

Working principle

 

magnetic induction

induced eddy current

 

Measuring range(mm)

0~400

0~1250

0~10000

0~400    

0~1250

10~200

 

( chromeplating upon copper base set  0~40)

 

 Resolution (mm)

0.1

0.1

10

0.1

0.1

1

 

Tolerance

 1point calibration (mm)

±(3%H+0.7)

±(3%H+1)

±(3%H+10)

±(3%H+0.7)

±(3%H+1.5)

±(3%H+1)

 

 2point calibration (mm)

±(1%H+0.7)

±((1%H+1)

±(1%H+10)

±(1%H+0.7)

±(1%H+1.5)

--------

 

Measuring condition

 

Min curvature radius (mm)

 

convex

1

1.5

flat

 

10

convex

1.5

3

flat

Only flat

 

 Min

                                measure area(mm)

 

F3

 

 

F7

F7

F4

F4

F5

F5

F7

 

 

Critical substrate thickness(mm)

0.2

 

0.5

0.5

2

0.3

0.3

0.3

No limit

 

Hot Products

Mining rope detector,steel rope flaw detector Specifications Standards: GB/T21837-2008, ASTM E1571...
Digital Ultrasonic Flaw Detector FD201, UT, flaw detector, ultrasonic testing equipment, ndt, ...
Product Info.: ·Automated calibration Automated gain ·Automated make video of test process and play ...
Digital ultrasonic flaw detector FD201B, ultrasonic detector, NDT, UT, ndt test Features for digital ...
real and reliable signal and echo 4A / 9V ultrasonic flaw detector FD100 Analog Features Real and ...
TOFD-400 Ultrasonic Flaw Detector,TOFD technique is to use the work of a new ultrasonic non...