GB ISO 36KV Gas Fully Insulated Switchgear Medium Voltage Ring Main Unit

 

Product Introduction

 

General

 
VCB unit, as known as V-unit has vacuum bubble, uses for breaking short-circuit current, one double-position disconnecting switch
is connected in series with the circuit breaker.
When the disconnecting switch at the open position, the interlocked earthing switch can be closed to ground the cable cassing.
The operation between the VCB and the disconnecting switch, and the operation between the disconnecting switch and the
earthing switches are mechanically interlocked.

 

Service environment

  • Air temperature: -35℃~+40℃
  • Humidity: Monthly average 95%; Daily average 90%.
  • Altitude:≤ 1000m (Up to 5000 m can be custom)
  • Ambient air not apparently polluted by corrosive and flammable gas, vapor, etc.
  • No frequent violent shake

Technical Data

No.ItemUnitParameter
1Rated voltagekV122436
2Rated frequencyHz50/60
3Rated currentA630(1250*)
4

1min Power frequency

withstand voltage

wetkV385070
drykV486085
5Lightning impulse withstand voltagekV75125/150170
6Rated short circuit breaking current (peak)kA806363
7Rated active load and close circuit breaking currentA635050
8Rated transferring currentA170012001200
9Rated short circuit making a current (peak)kA806363
10Rated cable(line) charging breaking currentA

50 and 10

50/10

11Cable charge breaking current in earthing faultA202020
12Rated withstand current (peak)kA806363
13Short-time withstand current (2s)kA252020
14Mechanism lifetimes500020002000

Note: For short circuit breaking and the peak current is based on Fuse plus combination

 

 

Hot Products

KYN28A-12KV for 6KV withdrawable switchgear Voltage: 12KV Current:630-2000A Circuit breaker: Vacuum ...
Withdrawable vacuum circuit breaker for medium voltage use KYN28A-12 Voltage: 12KV Current: 630...
Withdrawable VCB medium voltage switch panel KYN28A-12 metal-clad type Voltage: 3.6-24KV Current: ...
IEC GB standard 12KV 1250A KYN28 metal-enclosed switchgear for power plants use Voltage: 3.6KV-24KV...
KYN28A-12KV medium voltage 3.6KV 6.6KV 12KV 24KV withdrawable switchgear Voltage: 12KV Current:630...
Vacuum circuit breaker type switchgear KYN28 for medium voltage using Voltage: 3.6KV 6.6KV 12KV 24KV ...