Beijing Zetron Technology Co., Ltd |
Verified Suppliers
|
|
MIC300-VOC-H Online Toxic and Harmful Gas Detector
Type | Fixed Gas Detector | ||||
Allowable error | ≤±3% F.S (other or higher precision levels can be customized) | ||||
Linearity | ≤±2% | Repeatability | ≤±2% | Uncertainty | ≤±2% |
Response time | T90≤30 seconds | Recovery time | ≤30 seconds | ||
Working environment | Temperature: -40 ℃ ~ + 70 ℃, humidity: ≤10 ~ 95% RH (regular) | ||||
Power supply reference | 24V, 2.1A is possible to drive 40 units of toxic gas detector, or 15 units of flammable, infrared gas detector. | ||||
Working method | Fixed type installation, online detection, diffusion type
measurement | ||||
Protection level | IP65 | ||||
Explosion-proof mark | ExdⅡCT6, certificate number: CNEx15.1283 | ||||
Exterior dimensions | 233×205×65mm (L×H×W) | ||||
Weight | 1.0 Kg | ||||
Standard accessories | Manual, qualification certificate, warranty card, outer packaging
box |
Gases to be detected | Range | Accurancy | Resolution | Response time T90 |
Ethylene ( C2 H4 ) | 0-100%LEL | <±2%(F.S) | 0.1%LEL | ≤30 seconds |
Acetaldehyde | 0-10ppm | <±2%(F.S) | 0.01ppm | ≤30 seconds |
Ethanol ( C2 H6O ) | 0-100ppm | <±2%(F.S) | 0.01ppm | ≤30 seconds |
Methanol ( CH4O ) | 0-100ppm | <±2%(F.S) | 0.01ppm | ≤30 seconds |
Combustible gas ( EX ) | 0-100%LEL | <±2%(F.S) | 0.1%LEL | ≤10 seconds |
Methane ( CH4 ) | 0-100%Vol | <±2%(F.S) | 0.1%Vol | ≤10 seconds |
Oxygen gas ( O2 ) | 0-30%Vol | <±2%(F.S) | 0.01%Vol | ≤10 seconds |
Nitrogen gas ( N2 ) | 0-100%Vol | <±2%(F.S) | 0.01%Vol | ≤10 seconds |
Hydrogen gas ( H2 ) | 0-40000ppm | <±2%(F.S) | 1ppm | ≤30 seconds |