SALE good design Crioterapia coolplas the newest cool shaping cryo /SCV-102 model fat freezing machine

 

Coolplas technology:


A number of methods have been attempted for lipolaser including the use of laser, ultrasound, and radiofrequency electric current, since coolplas was developed applying cooling to tissue, was approved as the most effective way to fat reduction.
This revolutionary new idea of dissolving fat, which is approved as an important technology progress in fat reduction since it is put into use.
For those people who are on diet, do regular exercise but still remove local fat, Coolplas definitely a great gift. For fat intensive parts and less parts, such as love handles (flanks), and back fat. (Loose fat above the hip on both sides of waist), belly and back fat, Coolplas can produce stunning results.

 

The best treatment instruments
1. Hot spot of non-surgical medical cosmetic technologies, more advanced than RF slimming.
2. Only need very little time to do the treatment.
3. Destroy 20-26 % fat of the treatment area one treatment.
4. Without post operative recovery time, no affect to the life and work.
5. Non-invasive way to eliminate fat in waist, back and cellulite selectivity.
6. Most popular way to lose weight in Europe and U.S

 

Preparations Before Operation

 

1) Recommended treatment parts: the upper arm, back, abdomen, love handle, leg and buttock;

2) Measure fat thickness of treatment part;

3) 10-60min; Set treatment time 10-60min based on fat thickness of treatment area;

4) Treatment area should be kept small; a large patch of treatment area could be divided into several small parts.

5) Number of treatment parts for each time should be below 2. The same treatment areas should not take second treatment within 2 months. Different treatment areas can take second treatment after 1 month. Then extra fat thickness can be reduced and burden of metabolism decreased.

6) Generally, it is suggested to carry out treatment based on provided clinical parameters, temperature range is from 0℃ to -8℃; if the operator is a professional doctor, temperature can be adjusted combining relevant factors. The temperature should not be below -8℃.

 

 

Treatment Process

 

1) Check whether patient’s heartbeat is normal and consult whether he or she has other contraindications (for detailed information, see 5.2 contraindications);

2) Measure fat thickness of treatment part ;

3) Clean treatment part;

4) Mark treatment area;

5) Unpack small packet of gelpad, and wipe handpiece edge and inside part;

6) unpack big packet of gelpad, and apply it into treatment area.

7) patient shall be in a sitting posture and the upper body should be kept 90 degree with thigh;

8) Choose proper treatment handpiece based on fat thickness.

9) Start the equipment, and operate according to device operation interface and complete parameters setting;

10) Gentlely apply treatment handpiece cavity on treatment area and click button on handpiece;

11) In order to make sure that handpiece is closely touched on treatment areas, press it and lightly swing it up and down and then fix handpiece.

12) Click the button on handpiece, start treatment.

 

 

Attention:

 

1) The operator should be professional;

2) During treatment process, gelpad shall cover all treatment areas in case of cold injury;

3) Clinical data shows treatment for different body parts may cause cold injury, thus temperature setting should be based on fat thickness or provided by professional doctors;

4) When treatment part is focused on abdomen, the temperature should be relatively lower and avoid navel part.

5) Do not treat a patient with large treatment area. For example, as shown in the picture on the right: if treatment area is ①, area ② or ④ are not allowed to be treated, area ③ is allowed to take treatment, or metabolic disorder or even metabolic acidosis may be caused.

6) Patients with contraindications shown in 5.2 are not allowed to use this equipment;

7) Please pay attention to observe, if sense or body injured patient is in treatment;

8) In the halfway of treatment time, massage the patient for 8 minutes through negative pressure control and improve blood circulation and achieve better therapeutic effects.

9) Keep contacting with patient during treatment process, pay attention to ask patient’s feeling and adjust treatment parameters.

 

 

Technical Parameter

 

Freezing Temperature0℃— -8℃
Negative Pressure LevelLevel 1-10
Screen10.4-inch colorful touch screen
Duration1-60min
Refrigerating Systemsemi-conductor cooling, water cooling and wind cooling
Input220-240VAC, 50/60Hz,1500VA
Dimension (W×D×H)300mm×400mm×900mm
Weight30Kg

 

 

Hot Products

Professional hair removal and skin rejuvenation machine Intensive Light (IPL) IPL Beauty Machine ...
Multifunctional hair removal and skin rejuvenation beauty machine IPL SHR machine with FDA Treatment ...
Good service! Sincoheren professional opt shr ipl hair removal machine with FDA The principle of SHR ...
2018 stationary multifunction opt shr for skin rejuvenation hair removal machine The principle of ...
Factory directly supply SHR IPL hair removal machine IPL skin rejuvenation The principle of ipl shr ...
Ipl treatment system skin rejuvenation beauty machine shr hair removal machine The principle of ipl ...