Product Details

3 phase dc moulded case circuit breaker , Low Voltage TGM53 series 690V 800A

 

Application:

 

The TGM53 series moulded case circuit breaker is supplied with rated insulating voltage 690V and used for circuit of AC 50/60Hz, rated operating voltage AC 690V (or below), rated operating current up to 800A for infrequently changing over and starting of the motors.

 

Normal Working and Installation Conditions

Ambient temperature: -5 ~ 40 , daily average over 35

Altitude not more than 2000m; covering the product

Polluted class: 3 grade

Installation class: 3 grade

Mounting conditions: the mounting inclined angle shall not more than +5

Impact vibration: there shall have no severe vibration, impact and vibration.

 

Model meaning

 

Main technical parameter

Circuit breaker

 

TGM53-125

TGM53-160

TGM53-250

Pole

P

3P,4P

3P,4P

3P,4P

Using sorts

Grade

A

A

A

Rated current ln

A

12.5,16,25,25,32,40,

50,63,80,100,125

16,20,32,40,50,63,

80,100,125,160

100,125,160,180,

200,225,250

Rated frequency

Ac HZ

50/60

50/60

50/60

Rated working voltage Ue

V

400/500

400/690

400/690

Rated insulation voltage Ui

V

500

690

690

Rated impact withstand voltage Uimp

V

6000

8000

8000

Breaking capacity grade

 

L

H

L

H

L

H

Rated limit short breaking capacity Icu(O-t-CO)

400v kA

16

25

35

65

16

35

690V KA

8(500v)

18(500v)

14

18

6

8

Rated running short breaking capacity Ics(O-t-CO-t-CO)

400V KA

8

2.5

26

48

12

17.5

690V KA

4(500v)

12.5(500v)

11

13.5

4

6

operating cycle times

Per hour times

120

120

120

Through current times

1000

1000

1000

Non-current times

7000

7000

7000

subscribe to non-trip time t(h)

1.05ln

1(ln≤63A),2(ln>63A)

1(ln≤63A),2(ln>63A)

 

subscribe to trip time t(h)

1.3ln

1(ln≤63A),2(ln>63A)

1(ln≤63A),2(ln>63A)

 

power consumption

Fixed W

25

30

50

65

30

40

Plug-in

30

40

65

80

40

50

overall dimensions

3P mm3

120x78x70

120x90x70

170x105x103.5

4P mm3

120x103x70

120x120x70

170x140x103.5

 

Circuit breaker

 

TGM53-400

TGM53-630

TGM53-800

Pole

 

3P,4P

3P,4P

3P,4P

Using sorts

 

A

A

A

Rated current ln

A

200,225,250,

315,350,400

400,500,630

630,700,800

Rated frequency

Ac HZ

50/60

50/60

50/60

Rated working voltage Ue

V

400/690

400/690

400/690

Rated insulation voltage Ui

V

690

690

690

Rated impact withstand voltage Uimp

V

8000

8000

8000

Breaking capacity grade

 

L

H

L

H

L

H

Rated limit short breaking capacity Icu(O-t-CO)

400v kA

35

65

50

80

50

80

690V KA

20

25

20

25

20

25

Rated running short breaking capacity Ics(O-t-CO-t-CO)

400V KA

26

48

30

60

30

60

690V KA

10

12.5

10

12.5

10

12.5

operating cycle times

Per hour times

60

60

20

Through current times

1000

1000

500

Non-current times

4000

4000

2500

subscribe to non-trip time t(h)

1.05ln

2

2

 

subscribe to trip time t(h)

1.3ln

2

2

 

power consumption

Fixed W

60

80

135

150

135

150

Plug-in

90

100

150

220

150

220

overall dimensions

3P mm3

254x140x103.5

268x210x103.5

268x210x103.5

4P mm3

254x184x103.5

268x28x103.5

268x280x103.5

 

Overall and installation dimension

(Fixed type backplate wiring)

 

 

 

Plug-in backplate wiring

 

Hot Products

3 Phase TGM1-800A 1250A moulded case circuit breaker MCCB Product Description TGM1 series molded ...
Moulded Case Earth Leakage Circuit breakers MCCB ELCB 100A 225A TGM1L Application TGM1L series ...
electrical Earth Leakage Circuit breaker Moulded Case , MCCB ELCB TGM1L 400A 800A Main Technical ...
3 phase dc moulded case circuit breaker , Low Voltage TGM53 series 690V 800A Application: The TGM53 ...
660V AE20 3P Electrical Molded Case Circuit breaker Types 16-63A Russian type AE2040M, AE2040, ...
MCCB ABE series DC 250V AC600v 400A automatic moulded case circuit breaker ABE/ABS mccb is suitable ...