High Precision Walk Through Detector Gates For Body Temperature Screening

Country/Region china
City & Province shenzhen guangdong
InquireNow

Product Details

Non Contact Walk Through Temperature Detector Infrared Intelligent Door 200W

product introduction:

The door detect temperature by infrared temperature sensor with high precision and high resolution. the sensing distance ≤ 0.5 meters, the temperature tolerance is ± 0.5 ℃ at room temperature The original setting temperature is 37.6 ℃ (can be adjusted). the actual detection temperature will be displayed when people pass, The alarm will sound When the temperature exceeds 37.6 ℃.No temperature displays without passing people

Product parameters:

Temperature detection tolerance: ± 0.5 ℃ (at room temperature)

Voltage: 220V ~ 250V

Power: 200W

Net weight: 50kg

Inner frame dimension: 2000mm (H) × 700mm (W) × 500mm (d)

Outer frame dimension: 2270mm (H) × 830mm (W) × 500mm (d)

Application:

Railway station, bus station, subway station, hospital, gymnasium, factory, office building, large-scale events and other public places.

Product characteristics:

(1) The machine is more accurate to two decimal places (generally other machines only display one decimal place)

(2) The sensor probe can be adjusted automatically based on height of passing people

(3)Fast and convenient installation, i.e. ready to use

Chapter II precautions

The purpose of the following safety precautions is to tell you how to operate the product safely and correctly. Please read them carefully and make sure you understand them before reading other parts of this introduction

1, This product is only suitable for indoor use, the environment temperature will affect detection results if outdoor use

2, Operation is not allowed in high temperature and humidity condition.

3, Only professionals are allowed to dismantle and adjust the parameters in the electrical control box.

4, To get accurate detection results ,This machine have to take 5 minutes as self-check before operation

5,To avoid passing people collision with the door, It shall be installed on the flat and vibration free ground

6,A warranty card has been put into package, free of charge during the warranty period.

7, There are expansion bolts at four corners, which must be fixed and driven into the ground.

(1) Static Detection:

The tested person stands at the door and keep stay. The body temperature will be shown in display screen

(2) Dynamic Detection Displaying the detection temperature in real time when people pass

 

(3) Detection Report

A. If the body temperature is below setting temperature (37.6 ℃), the green indicator light will be on. The representative has been tested, and the temperature of the current tested people is dynamically displayed on the display screen. As shown in the figure.

B. If the body temperature is over the setting temperature (free setting, generally: 37.3 ℃), the red indicator light will be on, and the machine will alarm.

 

Operating instructions for setting of through type temperature detection door

part I: assembly:

1.Remove the package, fix the door frame, and fix the temperature detection box on the door frame at the same time;

2. Plugin the power supply; the screen display is starting; waiting for 1-3 seconds, and "00.00" appears on the box screen, and it is red and green alternately, indicating that the start is completed;

Part II: debugging:

Generally, the factory is set to the quick passing mode, which is the mode used after the machine is started. The steps are as follows:

 

1. Click "setup menu" on the screen;

2. Click "mode setting" and set it to "mode 6" through "+" or "-"; when you see mode 6, it is normal;

Click "finish" on the screen; save through the above confirmation mode;

Next, we set the temperature deviation value and high temperature alarm value in this mode. The steps are as follows:

1. Set the bias value:

(1) Click "environment parameters";

See: 6.5 or 7.0; adjust by "+," - ";

This value is the increase or decrease adjustment of the test results. If the temperature is high, the parameter value will be reduced, otherwise, it will be increased.

(2) Click "confirm" again to save;

2. High temperature alarm setting;

(1) Click "alarm temperature 2";

(2) Adjust by "+," - ";

(3) Click "confirm" again to save;

(if it's already 37.5 degrees, it doesn't need to be noticed. This value is the alarm value of the temperature);

3. Alarm temperature 1 setting;

(1) Click "alarm temperature 1";

(2) Adjust by "+," - ";

(3) Click "confirm" again to save;

(the default value of the system is 35.0 degrees, i.e. when the measured temperature exceeds 35.0 degrees, the green light will be on);

4. Sensing distance setting;

(1) Click "alarm temperature 2";

(2) Adjust the sensing distance by "+," - ";

(3) Click "confirm" again to save;

(if it's already 55, don't worry about it. This value means that the temperature measurement program will be started at 55cm before the person reaches the temperature box);

5. Alarm duration setting;

(1) Click "alarm time";

(2) Adjust the sensing distance by "+," - ";

(3) Click "confirm" again to save;

(if it's 1500, don't worry about it. This value is the alarm time of abnormal temperature.);

  • Restore the factory settings;

(1) Click "restore factory";

The system will prompt whether to clear the statistical data. After selection, click OK to save;

After all parameters are set, click finish.

About the setting mode of temperature door and the setting of deviation correction in the mode:

Generally, when leaving the factory, it is set as the side head passing mode, which is the mode used after starting the machine. The steps are as follows:

Long press the middle key; (behind the detection box, there is a long hole, in which there are three small red buttons, the handle is put in, there is no power, do not be afraid, it can be operated with electricity);

See "1" on the number of digits on the screen;

Press the up and down buttons to "4". When you see 4, press the middle button. When you see "1" on the ten digits of the screen, you can adjust the mode by pressing the up and down buttons. Mode 1: side head through mode. It is also the factory mode.

Mode 2: side head passing mode;

Mode 3: stop and stay through mode; press the middle button to save;

In this step, the mode has been selected;

Next, we set the temperature deviation value and high temperature alarm value in this mode. The steps are as follows:

1. Set the bias value:

(1) Long press the middle key to see "1";

Press the middle key again to see: 6.5 or 7.0; adjust through the up and down keys;

Long press the middle key, look

(if it is 7.0, it will not be adjusted, that is, it will be defaulted to be this number first). Carry out the test, and this value is the increase or decrease adjustment of the test result. If the temperature is high, reduce this value, and try to debug.)

Press the middle key again to save;

2. High temperature alarm setting;

(1) Long press the middle key, and you will see "1" on the single digit;

(2) Through the up and down key adjustment, see "3";

(3) Press the middle key again, 37 will appear;

Adjust the setting to "37.5" by pressing up and down to increase or decrease;

(if it's already 37.5 degrees, it doesn't need to be noticed. This value is the alarm value of the temperature);

(4) Press the middle key again to save;

3. Sensing distance setting;

(1) Long press the middle key, and you will see "1" on the single digit;

(2) Through up and down key adjustment, see "6";

(3) Press the middle key again, 55 will appear; increase or decrease the sensing distance through the up and down keys;

(if it's already 55, don't worry about it. This value is that when a person reaches 55cm before the temperature box, the box will be opened for temperature measurement);

(4) Press the middle key again to save;

4. Alarm duration setting;

(1) Long press the middle key, and you will see "1" on the single digit;

(2) Through up and down key adjustment, see "7";

(3) Press the middle key again, 1500 will appear;

(if it's already 1500, don't care. This value is the length of abnormal temperature alarm time);

(4) Press the middle key again to save;

Hot Products

4 CH 720P Full AHD Car Mobile DVR Dual SD Card with 4G GPS Wifi Optional Main Features: H.264 image ...
3.0 MP Car IP Dash Cam System 4G GPS Wifi Function Dual SD Cards Video Recorder for Car Production ...
Star Light Sony Sensor AHD 960P Car Rear View Camera with HD Color Night Version CCTV Camera ...
Color display digital laser infrared thermometer temperature gun with data hold Feature 1.using high...
Non Contact Walk Through Temperature Detector Infrared Intelligent Door 200W product introduction: ...
Facial Recognition Terminal For Turnstile Temperature Access Control With Thermometer Sensor Product ...