HS6103 Single Phase Electricity Meter Test Bench

 

HS-6103 single-phase energy meter testing bench adopts SPWM digital power source technology, comprises high-grade standard digital watt-hour meter, multi-path voltage transformer, can implement multi-station high accuracy error testing.

This testing bench configurations humanized PC processing software, can provide an integrated solution of the energy meter automatic check. Meanwhile, it provides the requested DLL of the second development, has improved the self-control and management for the bench by a customer.

This testing bench can be widely used for the energy meter measurement and testing in electric power, water conservancy, traffic transportation and colliery departments, as well as the energy meter testing and production of the energy meter manufacturer.

This series of testing bench can test all kind of single-phase energy meters, single-phase multi-function meters, single-phase intelligent meters, other meters with special wiring and ANSI standard meter. It is an ideal new generation multi-station energy meter testing device.

 

  • base on A/D and DSP technology
  • adopt precise digital synthesized technology and sine PWM technology
  • adopt intelligent system control technology, multi-CPU coprocessing technology
  • reliable multi-path pulse testing and precise error testing treatment technology
  • SPWM technology power amplifier, large capacity, high performance, low power consumption, automatic warning protection
  • Error processor of each station distributed networking, heavy current protection, support multi-path pulse signal input
  • Can configurate serial server, implement parallel communication of muti-station, improve work efficiency
  • Modular design, have good universality of parts, easy to disassemble and maintain
  • One-button checking and control management system, automatic finish as per the project
  • Standard cabinet, aluminum alloy frame, nicer and stronger
  • Customized as per specific function

 

 

Parameter Item0.030.050.1
Reference standard energy meterHS-5100H 0.02HS-5100 0.05HS-5100 0.1
Output rangeVoltage:30~300V
current:1mA~120A
Voltage:30~300V
current:10mA~120A(
200A optional)
Output phase shift0~360°,resolution:0.01°
Output frequency45~65Hz ,resolution:0.01Hz
Waveform distortionBoth voltage and current<0.5%(relative liner load)
Voltage &current power stability<0.03%/120s<0.05%/120s<0.1%/120s
Output capacity

Voltage:200VA

(6 stations)
current:250VA(120A);

Voltage:400VA(24 stations)current:900VA(120A)
if add meters, Max. current: 2000VA,Max. voltage: 1200VA
Load characteristicsResistive, inductive and capacitive(less than 1uF/station,Max. less than 48 uF)
Starting up current outputMin.1mA(0.3mA optional),accuracy:5%,starting power:accuracy 5%
sampling pulse input≤1kHz
Communication testingRS485/232/infrared/carrier wave,support DL/T645-1997/2007,IEC1107
Number of meters to be tested24,48(standard),3~60 (optional)
Environment conditiontemperature:20℃±5℃;humidity:<85% R.H.
Power supplyAC 220±10%,50/60Hz,AC120/240V(optional);
Max. power consumption:1500VA(24 stations)

 

 

integrationstationsNumber of rackdimension:L×W×HfissionstationsNumber of rackdimension:L×W×H
611600×750×16001211600×700×1920
1600X800X11002412200×700×1920
1211600×750×19204822200×700×1920
2412200×750×19206022000×700×1920
4822200×750×1920cabinet600×800×1920

 

 

TypedescriptionRange of application
HS-6103Single-phase energy meter testing benchStandard energy meter testing
HS-6103BSingle-phase multi-function energy meter testing benchMulti-function energy meter testing
HS-6103CSingle-phase horizontal energy meter calibration benchEnergy meter error calibration
HS-6103ESingle-phase energy meter test bench with ICTS1P3W energy meter testing
HS-6103FSingle-phase intelligent energy meter testing benchintelligent energy meter testing
HS-6103GSingle-phase energy meter (round meter) testing benchANSI standard energy meter testing
HS-6103MSingle-phase din-rail energy meter testing benchdin-rail energy meter testing
HS-6103HSingle-phase high precision energy meter testing benchhigh precision energy meter testing

 

Function itemHS-6103HS-6103BHS-6103CHS-6103EHS-6103FHS-6103GHS-6103MHS-6103H

Base testing

functions

Base error
Creep testing
Starting up testing
standard deviation
Constant calibration
Counting error
Influencing testing
Multi-function testingDaily timing error☆   
Period switching    
Energy display error      
register checking      
GPS clock synchronization☆ 
Communication testing☆ 
  • :●─standard;〇─optional.

For Item ☆ need special function parts

 

TypeHS-6103HS-6103BHS-6103CHS-6103EHS-6103FHS-6103GHS-6103MHS-6103H
Standard energy meter
power source
error processing system
multi-path pulse input 
auto searching mark
Double circuit current 
auto short circuit 
cutting Neutral testing      
multi-path PT
ICT       
parallel communication 
carrier communication  
IR communication 
power consumption testing      
DC and even harmonic wave      
standard clock tester   
GPS clock synchronization 
collective turn over & optoelectronic sampling 
  • :●─standard;〇─optional


48 POSITION SINGLE-PHASE PREPAID DIGITAL KWH METER TEST BENCH


 

Technical Specification:
1. No. of test points: 48 meters
2. Can test smart meter
3. Accuracy Class: 0.05 IEC standard
4. Multiplex voltage transformer accuracy class: 0.01
5. Rated Load Per Point: 15VA
6. Output Voltage: 220V or 240V; Adjustment range: 0-120%; Adjustment resolution: 0.01%
7. Output Current Range: 0-120A; Adjustment resolution: 0.01%
8. Phase Angle Range: 0-360deg; Adjustment resolution: 0.01 deg
9. Output wave distortion (both voltage and current): <0.5%
10. Output capacity, current: 2000VA (120A); voltage: 720 VA(48 meters)
11. Load characteristics: resistive, inductive, and capacitive (<4uF)
12. Starting current output: 5mA (min.); Accuracy of starting power: 5%
13. Test items: accuracy test, creeping test, starting test, harmonic test, repeatability test, influence test
14. Power supply: 200V-250V; 60Hz; Maximum power: 2500VA (48 meters)

 

 

Hot Products

HS-3303 Three Phase Portable Energy Meter Test Bench HS-3303 serial products are small-sized, light...
HS-3303 Three Phase Portable Energy Meter Test Bench HS-3303 serial products are small-sized, light...
HS 3303 Three Phase Portable Energy Meter Test Equipment (For testing whole current 3 phase meter ...
HS-3303 Three Phase Portable Energy Meter Test Bench HS-3303 serial products are small-sized, light...
HS-3303 Three Phase Portable Energy Meter Test Bench (Moveable rack,3 Position,Internal Reference ...
HS6103 Single Phase Electricity Meter Test Bench HS-6103 single-phase energy meter testing bench ...