Home Companies Zhejiang Shengdi Technology Inc.

48 Positions Single Phase Electricity Meter Test Bench,1-phase 2 wire meter,0~100A current

Zhejiang Shengdi Technology Inc.
Active Member

Contact Us

[China] country

Address: #8,Zhenghua Road,Wuyuan Industry Zone,Haiyan County

Contact name:Yeli Lu

Inquir Now

Zhejiang Shengdi Technology Inc.

48 Positions Single Phase Electricity Meter Test Bench,1-phase 2 wire meter,0~100A current

Country/Region china
Categories Other Electric Power Tools
InquireNow

Product Details

HS6103F Single Phase Electricity Meter Test Bench


TECHNICAL SPECIFICATION                                                                     

 

1. No. Of test seats: 48 meters

2. Can test both mechanical and electronic meters.

3. Accuracy Class: 0.05 IEC standard

4. Reference meter: 0.05% accuracy class

5. Multiplex voltage trnasformer accuracy class:0.01,rated load per seats:10VA

6. Current connection type: Dual loop :1-4,3-2

    Dual Loop means: Neutral wire and Live wire

7. Output Voltage: 220V or 240V; Adjustment range: 0-120%;

Adjustment resolution: 0.01%

8. Output Current Range: 0-100A;Adjustment range: 0-120%

Adjustment resolution: 0.01%

9. Phase Angle Range: 0-360deg; Adjustment resolution: 0.01 deg

10. Frequency: 45Hz-65Hz,Resolution:0.01Hz.

11. Output wave distortion (both voltage and current): <0.5%

12. Output voltage,current,and power stability: <0.05% /180s

13. Output capacity:Current:1000VA(120A);Voltage:400VA(24 seats)

Current:2000VA(120A);Voltage:800VA(48 seats)

14. Load characteristics: resistive, inductive, and capacitive (<4uF)

15. Harmonic Wave Output :

2 ~ 21 sub-harmonic wave Contents of Harmonic Wave < 40%

3, 5, 7 sub-harmonic wave coupling, contents of each harmonic wave <10%

Phase angle control (odd sub-harmonic wave)

Wave group control (sub-harmonic wave)

16. Testing functions:accuracy testing,creep testing(no load testing),starting

Up testing,harmonic testing,repeatability testing,influencing testing,dial testing etc.

17. Power supply: 240V, 50Hz.

 

Main Information:

No. of test MetersStandard: 24 and 48 ,Also 3-60 Meters are available
Accuracy Class0.05% or 0.1%
Output Voltage220 or 240V,Range:0~125%
Output CurrentStandard: Max120A Custom: 200A
Test Function

Accuracy testing,

creep testing(no load testing),

starting Up testing,

harmonic testing,

repeatability testing,

influencing testing,

dial testing etc.

Communication Mode1.M-Bus
2.Seperated Communication Port(MOXA and Serial Port Server)

 

Dimensitions:

integrationstationsNumber of rackdimension:L×W×HFissionstationsNumber of rackdimension:L×W×H
611600×750×16001211600×700×1920
1600X800X11002412200×700×1920
1211600×750×19204822200×700×1920
2412200×750×19206022000×700×1920
4822200×750×1920Cabinet600×800×1920

 

STRUCTURE DETAILS.                                                          

 

1. CABINET (600*800*1920 mm)

    With (1 piece HS-5100 Reference Meter,1 piece HS-6611 Signal source & 1 piece Power source)

 

2. TEST RACK ( 2 set)

  With( Quick Connector,Scanning head,Error Processor)

 

 

Hot Products

HS-3103 Portable Single Phase Energy Meter Test Bench Overview HS-3103 serial products are small...
HS-3103 Portable Single Phase Energy Meter Test Bench Overview HS-3103 serial products are small...
HS-3P100A THREE-PHASE PHANTOM LOAD CURRENT GENERATOR TECHNICAL SPECIFICATION 1. Rate Power Supply: 2...
HS-3303B Three Phase Portable Energy Meter Test Bench HS-3303 serial products are small-sized, light...
HS-3303B Three Phase Portable Energy Meter Test Bench HS-3303 serial products are small-sized, light...
HS-3303B Three Phase Portable Energy Meter Test Bench HS-3303 serial products are small-sized, light...