Home Companies Zhejiang Shengdi Technology Inc.

HS-6103F Single-Phase Static Meter Test Bench 48 calibrated energy meters 0.05% accuracy class active & reactive energy

Zhejiang Shengdi Technology Inc.
Active Member

Contact Us

[China] country

Address: #8,Zhenghua Road,Wuyuan Industry Zone,Haiyan County

Contact name:Yeli Lu

Inquir Now

Zhejiang Shengdi Technology Inc.

HS-6103F Single-Phase Static Meter Test Bench 48 calibrated energy meters 0.05% accuracy class active & reactive energy

Country/Region china
Categories Other Electric Power Tools
InquireNow

Product Details

HS6103 Single Phase Electricity Meter Test Bench

  • Overview:

HS-6103 single-phase energy meter testing bench adopts SPWM digital power source technology, comprises high grade standard digital watt-hour meter, multi-path voltage transformer, can implement multi-station high accuracy error testing.

This testing bench configurates humanized PC processing software, can provide integrated solution of the energy meter automatic check. Meanwhile, it provides the requested DLL of the second development, has improved the self-control and management for the bench by customer.

This testing bench can be widely used for the energy meter measurement and testing in electric power, water conservancy, traffic transportation and colliery departments, as well as the energy meter testing and production of the energy meter manufacturer.

This series of testing bench can test all kind of single-phase energy meters, single-phase multi-function meters, single-phase intelligent meters, other meters with special wiring and ANSI standard meter. It is an ideal new generation multi-station energy meter testing device.

  • functional advantage:
  • base on A/D and DSP technology
  • adopt precise digital synthesized technology and sine PWM technology
  • adopt intelligent system control technology, multi-CPU coprocessing technology
  • reliable multi-path pulse testing and precise error testing treatment technology
  • SPWM technology power amplifier, large capacity, high performance, low power consumption, automatic warning protection
  • Error processor of each station distributed networking, heavy current protection, support multi-path pulse signal input
  • Can configurate serial server, implement parallel communication of muti-station, improve work efficiency
  • Modular design, have good universality of parts, easy to disassemble and maintain
  • One-button checking and control management system, automatic finish as per the project
  • Standard cabinet, aluminum alloy frame, nicer and stronger
  • Customized as per specific function

 

Technical Parameters:

 

Parameter Item0.030.050.1
Reference standard energy meterHS-5100H 0.02HS-5100 0.05HS-5100 0.1
Output range

Voltage:30~300V
current:1mA~120A

Voltage:30~300V
current:10mA~120A(200A optional)

Output phase shift0~360°,resolution:0.01°
Output frequency45~65Hz ,resolution:0.01Hz
Waveform distortionBoth voltage and current<0.5%(relative liner load)
Voltage &current power stability

<0.03%/120s

0.05%/120s

<0.1%/120s

Output capacity

Voltage:200VA

(6 stations)
current:250VA(120A);

Voltage:400VA(24 stations)current:900VA(120A)
if add meters, Max. current: 2000VA,Max. voltage: 1200VA

Load characteristicsResistive, inductive and capacitive(less than 1uF/station,Max. less than 48 uF)
Starting up current outputMin.1mA(0.3mA optional),accuracy:5%,starting power:accuracy 5%
sampling pulse input≤1kHz
Communication testingRS485/232/infrared/carrier wave,support DL/T645-1997/2007,IEC1107
Number of meters to be tested24,48(standard),3~60 (optional)
Environment conditiontemperature:20℃±5℃;humidity:<85% R.H.
Power supplyAC 220±10%,50/60Hz,AC120/240V(optional);
Max. power consumption:1500VA(24 stations)

 

Dimensions(unit:mm)

integrationstationsNumber of rackdimension:L×W×HfissionstationsNumber of rackdimension:L×W×H
611600×750×16001211600×700×1920
1600X800X11002412200×700×1920
1211600×750×19204822200×700×1920
2412200×750×19206022000×700×1920
4822200×750×1920cabinet600×800×1920

 

Type & specification

TypedescriptionRange of application
HS-6103Single-phase energy meter testing benchStandard energy meter testing
HS-6103BSingle-phase multi-function energy meter testing benchMulti-function energy meter testing
HS-6103CSingle-phase horizontal energy meter calibration benchEnergy meter error calibration
HS-6103ESingle-phase energy meter test bench with ICTS1P3W energy meter testing
HS-6103FSingle-phase intelligent energy meter testing benchintelligent energy meter testing
HS-6103GSingle-phase energy meter (round meter) testing benchANSI standard energy meter testing
HS-6103MSingle-phase din-rail energy meter testing benchdin-rail energy meter testing
HS-6103HSingle-phase high precision energy meter testing benchhigh precision energy meter testing

 

Function parameters:

Function item

HS-6103 

HS-6103B

HS-6103C

HS-6103E

HS-6103F

HS-6103G

HS-6103M

HS-6103H

Base testing

functions

Base error
Creep testing
Starting up testing
standard deviation
Constant calibration
Counting error
Influencing testing
Multi-function testingDaily timing error☆   
Period switching    
Energy display error      
register checking      
GPS clock synchronization☆ 
Communication testing☆ 
  • :●─standard;〇─optional.

For Item ☆ need special function parts

 

Bench configuration

Type

HS-6103

HS-6103B

HS-6103C

HS-6103E

HS-6103F

HS-6103G

HS-6103M

HS-6103H

Standard energy meter
power source
error processing system
multi-path pulse input 
auto searching mark
Double circuit current 
auto short circuit 
cutting Neutral testing      
multi-path PT
ICT       
parallel communication 
carrier communication  
IR communication 
power consumption testing      
DC and even harmonic wave      
standard clock tester   
GPS clock synchronization 
collective turn over & optoelectronic sampling 
  • :●─standard;〇─optional

 

 

Hot Products

HS-3103 SINGLE Phase Portable Energy Meter Test Equipment HS-3103 serial products are small-sized, ...
HS-3303 Three Phase Portable Energy Meter Test Bench HS-3303 serial products are small-sized, light...
HS-3103 1 Position Portable Single Phase Meter Test Equipment Suit for Lab Output voltage and ...
HS3103 Portable 1 Phase Energy Meter Test Equipment Technical specification 1. Electrical output 1) ...
HS-3103 Portable Single Phase Energy Meter Test Bench Output voltage and current distortion not ...
HS3303 Portable 3 Phase Energy Meter Test Bench Technical specification 1. Electrical output 1) ...