Indoor 2.4G Wireless Microwave Motion Sensor For LED Ceiling Light
For more details, pls refer to as follows:
MC116D RC Spec 2024.01.17.pdf
【Product Features】
- Grouping networking by 2.4G wireless, no need paring or gateway.
- Patented di-pole microwave antenna, no false trigger when installed
beLOW metal LED tray.
- Super-narrow microwave senor head, suitable to be fixed in slim LED
fixtures.
- All sensor parameters can be set by remote control.
- Output 0-10V dim or PWM dim, 2-step/3-step dim function.
- 6m Max. mouthing height.
【Parameter】
Input |
Rated voltage | 12±1VDC |
Working current | 55±5mA |
Ripple voltage | < 100mVp-p |
Output |
Output signal | ○0-10V Dimming Signal | ○PWM Dimming Signal |
Sensing parameters |
Working frequency | 5.8GHz ±75MHz, ISM band |
Transmit power | 1mW Max. |
Daylight priority | ON | 15Lux (LOW) | 50Lux (MED) | Disable (HIGH) |
OFF | 100Lux | 150Lux |
Stand-by DIM Level | < 50mA(Non-constant source) 10%(1.4-1.6V) 30%(2.9-3.3V) |
Detection range (radius) | Ceiling Mounting(height: 3m): 0.3m/s ≥4m, 1m/s ≥2.5m Wall Mounting(height: 2m): 0.3m/s ≥8m, 1m/s ≥4m |
Installation height | 3m ( 6m Max ) |
3db beam angle | 80 °@XZ plane |
96 °@YZ plane |
Wireless Module |
Operating Frequency | 2.4GHz |
Transmitting Power | 6dBm |
Transmitting Distance | 15m MAX(Point-to-point open area transmission distance) |
Environment |
Working temperature | Built-in: -25~60℃ |
Storage temperature | -40℃~80℃, humidity ≤85% (non-condensing) |
Certification Standards |
Certified | CE |
Environmental requirements | Comply with RoHS 2.0 , Reach requirements |
Degree of protection | IP20 |
Other |
Wiring | 3pin 2.0mm terminal |
Installation requirements | built-in installation |
Packaging requirements | Clapboard + paper carton(K=A) |
Net weight | 16.5±3g |
Life | 5 Years Warranty@Ta |
【Function description】
ON-OFF function | N/A |
√2-step dimming | Stand-by Period be set to “+∞”, Daylight sensor be set to “High” |
√3-step dimming | Stand-by Period be set to “5min/10min” |
Daylight harvesting | N/A |
√Daylight priority | Stand-by Period be set to “+∞”, Daylight sensor be set to “LOW/MED” |
Grouping | Remote group “1-8” and set Rx signal for sensor |
【Diagram】
【Remote Controller】
【Initialization】
When powering on for the first time, the sensor will turn the light
on to 100% brightness, and the light will be turned off after 10
seconds. During initialization, movement signal will not be
detected.
【Default setting】
Detection area: 100%; Hold Time: 10s; Stand-by Period: 0s; Daylight
Sensor: Disable;
Stand-by Dim Level: 10%.
【Application Notice】
- The sensor should be installed by a professional electrician.
Please cut off the power before installing, wiring etc.
- The detection distance is related to factors such as the moving
speed of the moving object, the size of the moving object, the
installation height, the installation angle, whether the
installation environment is open, and the material of the
reflector. The detection distance given in the specification is a
typical value, which is 165cm/65kg tester, and it is tested in an
open indoor environment
- When the microwave sensor is installed on the wall, the detection
distance will be greatly increased compared with that installed on
the ceiling. If you use the wall installation method, please reduce
the sensitivity to use or contact our company to confirm the use
settings. The light sensitivity threshold is in a sunny
environment, no shadows, and ambient light diffuse reflection
conditions. In different time periods, climates, and environments,
the illuminance value detected by the light sensor may be different
- Sensor parameters may need to be reconfigured in different
installation environments, please refer to the following
instructions or contact the manufacturer
- This sensor is only for indoor use, outdoor wind and rain, and
surrounding moving objects will cause false triggering
- The installation height of the sensor product cannot exceed 6
meters, and the optimal height is 3 meters; the distance between
the two sensors should be greater than 3 meters
- When the sensor is installed in a metal lamp, on a metal reflective
surface, or in a narrow closed environment, microwaves will be
reflected multiple times and cause false triggering. Please reduce
the sensor sensitivity or contact the manufacturer for technical
support.
- Please make sure that there are no moving signals such as fans, DC
motors, sewer pipes, air outlets, etc. around the sensor, otherwise
the sensor may cause false triggering.
- Microwaves cannot penetrate metal, avoid installing in closed or
semi-closed metal lamps, and there should be no metal or glass
blocking the product
- Sensor with different 0-10V / PWM driver, LOW light effect may be
different
- DC regulated power supply with stable output voltage and LOW ripple
coefficient must be used. The ripple of the power supply should be
less than 100mV ; the load current should be greater than 100 mA
- Product specifications and parameters may be optimized without
prior notice
- For the new installation environment, it is recommended to test
5pcs samples before installation.