Features
1.Digital signal processor for effective inhibition of
baseline drift, AC interference filter, MG interference filter and
the heart rate, to guarantee the authenticity and dependability
2.Auto-regulation of baseline drift can effectively inhibit
baseline drift, optimizing the printing position to achieve
high-quality ECG
3.Have regular automatically measuring and analyzing function
for ECG parameters to lessen doctor's load.
4.With a high -resolution thermal printer to print out ECG
trace, describing the trace clear and accurate, annotation as well
as related parameters for diagnostic reference.
5.Roll recording paper for ECG is 80mm in width, simultaneous
12 lead acquisitions and 3 lead live record, high affectivity of
ECG examination, good effect and economic utility.
6.Function of rhythm lead for observing abnormal ECG trace
& heart rate.
7.Supported by AC/Rechargeable battery for continuous
examination whenever necessary. For Battery operation.
8.ECG is equipped with a battery charger and a system for
battery capacity management and protection
Safety level for ECG corresponds to Type CF, Class I according to
the IC60601-1 criterion. The amplifier is floating input circuit
which can examine human cordis directly with safety and reliability
Main technical specification
Items | specification |
Lead | standard 12 leads |
lead acquisition | synchronously 12 leads |
Input circuit | Floating; Protection circuit against Defibrillator effect |
Input Impedance | ≥50MΩ |
Input circuit current | ≤0.0.05 A |
Record mode | Automatic: 3CH×4+1R, 3CH×4, 3СН×2+2CH×3,3CH×2+2CH×3+1R,6CHX2; Manual: 3CH, 2CH, 3CH+1R, 2CH+1R; Rhythm: Any lead selectable. |
Filter | EMG Filter: 25 Hz / 30 Hz/ 40H2/75 Hz/ 100 Hz / 150Hz DFT Filter: 0.05 Hz/ 0.15 Hz AC Filter: 50 Hz/ 60Hz |
CMRR | >100dB |
Patient current leakage | <10 A |
Input Circuit Current | <0.05 A |
Frequency Response | 0.05Hz~150Hz (-3dB) |
Sensitivity | 2.5mm/m V, 5 mm/m V, 10 mm/m V, 20 mm/mV |
Anti-baseline Drift | Automatic |
Time constant | ≥3.2s |
Noise level | <15 Vpp |
Paper speed | 12.5 mm/s, 25 mm/s, 50 mm/s |
Recording mode | Thermal printing system |
Paper specification | 80mmx20m paper roll |
LCD display | 7''graphic LCD |
Safety classification | IEC60601-1 class I, type CF |
Power supply | AC: 100~240V, 50/60Hz, 30VA~100VA |
DC: 14.8V/2200mAh, built-in lithium battery | |
Fuse | AC220V=10% 2*Ф5×20mm, T2A/250V AC time lag |
AC110V+10% 2*Ф5×20mm.T4A/250V AC time lag |
Accessories
Item | Description | Quantity |
1 | Patient Cable | 1 |
2 | Limb Electrode | 4pcs/set |
3 | Chest Electrode | 6pcs/set |
4 | Three plugged power cable | 1 |
5 | Grounding Cable | 1 |
6 | Paper Shaft | 1 |
7 | Thermal Recording Paper | 1 |