1.5V BF Type Medical Pulse Oximeter Plastic Material CMS50D2 With PI Value Display

Country/Region china
City & Province changsha hunan
InquireNow

Product Details

PI Value Display Medical Pulse Oximeter Over Limit Indication

 

Features

 

1) SpO2 value display
2) Pulse rate value display, bar graph display
3) Pulse waveform display
4) PI value display
5) The display mode can be changed
6) Low-voltage indication: low-voltage indicator appears before working abnormally

which is due to low-voltage
7) Pulse sound indication and over limit indication

8) Accurate and Reliable
9) Convenient To Carry
10) Advanced Feature
11) PERFUSION INDEX Display
12) Multi-directional Display
13) Alarm and Auditory Function

 

Package Contents
1. Standard configuration
Gift box, Hanging rope, Pulse oximeter, User manual.
2. Optional configuration
Carrying case, Battery

 

Specifications

 

1 ) Display Mode : 0.96 " color display
2 ) Screen Resolution : 128 * 64
3 ) SpO2 Measuring Range : 0 % ~ 100 % , ( the resolution is 1% )
Accuracy : 70% ~ 100% : ± 2 % , Below
70% unspecified.
4 ) PR Measuring Range : 30 bpm ~ 250 bpm , ( the resolution is 1 bpm )
Accuracy : ± 2 bpm or ± 2 % ( select larger )
5 ) PI Measuring Range : 0 % ~ 20 %
Accuracy : When the Pl measure range is 1% ~ 20% ,

the permission of absolute error is ± 1 %

When the Pl measure range is 0% ~ 0.9% ,

the permission of absolute error is ± 0.2%
6 ) Measurement Performance in Weak Filling Condition :

SpO2 and pulse rate can be shown correctly when pulse - filling ratio is 0. 4% .

SpO2 error is ± 4% , pulse rate error is ± 2 bpm or ± 2 % ( select larger )
7 ) Resistance to surrounding light : The deviation between the value measured in the condition of

man-made light or indoor natural light and that of darkroom is less than ± 1%
8 ) Power Consumption : less than 80 MA
9 ) Voltage : DC 2.6 V - 3 . 6 V
10 ) Power Supply : 1.5 V ( AAA size ) alkaline batteries x 2

11 ) Safety Type : Interior Battery , BF Type

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Hot Products

Cofoe Electronic Blood Glucose Meter Specification Product Name Cofoe Electronic Blood Glucose Meter ...
Electronic Digital medical Blood Glucose Meter With Voice Broadcast Features: 1. No code 2. Voice ...
250 Sets Of Memories Blood Glucose Test Meter Voice Broadcast Features: 1. No code 2. Alarm clock ...
CE Certificate Blood Glucose Meter Fast Measurement Blood Test Kits Glucose Test Meter Products ...
Digital Blood Glucose Meter With Blood Collection Pen Fast Measurement Blood Glucose Test Meter ...
300 Sets Of Memories Blood Glucose Test Meter Fast Measurement Features 1. Blood glucose meter can ...