Home Companies YUEMI

HQQE Vertical Grundfos Pump Mechanical Seal GLF-C-16mm 96511845

YUEMI

Contact Us

[China] country

Trade Verify

Address: Huadu District, Guangzhou City, Guangdong Province, China

Contact name:ZENG

Inquir Now

YUEMI

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

HQQE Vertical Grundfos Pump Mechanical Seal GLF-C-16mm 96511845

Country/Region china
City & Province guangzhou guangdong
Categories Other Inorganic Chemicals
InquireNow

Product Details

HQQE Vertical Grundfos Pump Mechanical Seal GLF-C-16mm 96511845

 

 

 

 

 

 

 

 

Application water pump model pairing table

 

 

 

 

 

 

Technical Parameters

 

 

Temperature-30℃~+200℃
pressure≤1.2Mp a
Speed≤10m/s
MediumAcid, alkali, below medium corrosive liquid

 

Materials

 

Rotary Ring

SiC/VIT

Stationary Ring

Carbon/SiC/TC

SpringSUS304/SUS316
Stationary SeatSUS304/SUS316
Secondary Seal

 VITON

Rotary Ring HolderSUS304/SUS316

 

 

 

China HQQE mechanical seal for submersible sewage pump

1.YUEMI plug in plastic is for CR pump
2. Our seals can replace the original seals.
3.Application: seals are primarily used in in Clean water,sewage water,oil and other moderately corrosive fluids etc.
It is ideal with high or pulsing counterpressure or with viscous or sticky fluids.

4.Standard:the products are in according with Din24960,ISO3069,en12576,API682 standards
5.OEM and Customized products is welcomed.
6. Factory Price,High Quality ,Fast Delivery and Best Sevice.


This product is in stock, we can ship them right away once the payment has been verified.

 

 

 

Preperation:
1. Shaft Outside Diameter is within tolerance +-0.05mm
2. Shaft run out <0.1mm
3. Shaf end float <0.13mm
4, No sharp edges on the shaft over the o ring


Note:
During the installation,don't scratch or damage the o ring.lf anything is damaged,please contactwith Us to replace a new one.


Installation in strucstions:
1. The full set of cartridge seal is cleaned and exactly passed leakage examine before sale.Inorder to avoid damage,don't disassemble and clean the parts again before fixing.

 

2 The fitting allowance between the seal and shaft is dl h6 0.8,and there should be leading-inedge at the end of shaft.The outside diameter of shaft at the position of screw should be 01 0.2mm smaller,resisting the screw over-tighten.Lubricate the shaft with oil

 

3. Place the cartridge seal into the pump chamber,then:
A: Tighter four screw bolts of flanges,ensuring the medium leading in hole"G"at the top Position

B : Tighter four set screws and position the shaft sleeve on the shaft.
C: Remove four gauge plates.Please keep them and they wil be used in future installation and
disassemble.
D: Connect the medium lead_in pipe with hole"G"in order to flush away the friction heat and
flushing the seal chamber when pump running.


Note:
ter complete the installation,turning the shaft by hand to check for the rotationi he shat could not rotate smoothily,seal had been improperly installed.

 

 

 

We would like lo sincerely ooperale with Clients to supply high qually products and senice We beleve in establishing a long:erm cooperalive relalionshipis lhe key to suceess

 

 

Hot Products

Double seal/Unbalanced/Independent of direction ofrotation /Multiple springs Double seals in the M7N ...
Due to the variety of working media and harsh working conditions of the pump, such as high speed, ...
In the petroleum, chemical and other industries, due to the various working media and harsh working ...
When sealing high-viscosity media, attention must be paid to the damping effect of the viscosity of ...
10k27 Grundfos Pump Mechanical Seal G3-12mm CHI 2/4 G3-16mm mechanical Shaft Seal Kit BQQEBUBE 12mm ...
Application water pump model pairing table GFE d D D1 L L1 L2 12 12 23 22 39 7.5 31.5 16 16 27 26 40...