Product Details

High Performance V Cone Flow Meter Wear-Resistant And Self-Cleaning


Product Description

V-cone flow meter is a differential pressure type flow measurement device. So far it is more than 100 years since all kinds of flow measurement device that based on pressure differential theory been used. Pressure differential theory is based on energy conversion principle in sealed piping, means that to the steady liquid, flux and flow velocity's square root is direct ratio.


Product Parameters

(1)Long-term stability:± 0.1% F.S / Y
(2)Output:4~20mA
(3)Repeatability:± 0.1%
(4)Minimum flow velocity:0.1m
(5)Turndown ratio:Normally15:1; max50:1
(6)Reynolds number range:8 × 103 ~ 5 × 106
(7)Operating pressure:≤ 16MPa, 42MPa(maximum)
(8)Operating temperature:-160 °C ~ 700 °C
(9)Nominal diameter:φ15~φ2000 (1/2"~120")
(10)Environment temperature:≤ 80 °C

 

Product Image

 

 

 

 

 

Working Principle:
V-cone flow meter is a differential pressure type flow measurement device. So far it is more than 100 years since all kinds of flow measurement device that based on pressure differential theory been used. Pressure differential theory is based on energy conversion principle in sealed piping, means that to the steady liquid, flux and flow velocity's square root is direct ratio. We know that pressure will reduce when velocity increase, when medium approaches to cone the pressure is P1, but when medium is passing to cone's throttled area, because passing area reduced, speed increased, pressure reduced to P2, both P1 and P2 are connected to differential pressure transformer through pressure mouth. When flow rate is changed, the pressure differential value will increase or decrease accordingly.

Features
1.Low installation requirement: Rectifying behavior changes the velocity distribution, eliminating the eddy current and blind space. upstream straight pipe 0-30D, downstream straight pipe 0-1D. 2. Turndown ratio : 10:1 (usually);50:1(maximum)
3. Small pressure loss and signal stability: V-cone differential pressure signal is high-frequency low-amplitude signals. When the same β value, the pressure loss is 1/3~1/5 of orifice plate's and signal fluctuation is 1/10 of orifice plate's.
4.Strong resistance against wear: After the streamline V cone is throttled, the vacuum effect will be generated on the surface of V cone to keep the V cone from being worn easily.
5.Automatic cleaning, no block, no adhesion: the complete purging design of V cone avoids the settlement of residue, coagulation or particle.
6.Long-standing favorable stability: the value of β can remain the same for long and the accurateness in measurement can be ensured for a long period.
7.High precision and good repeatability: accuracy:±0.5% F.S; repeatability:±0.1% F.S
8.Wide range of the value of β: the unique geometrical shape of V cone flow sensor allows wide range of the value of β.
9.Type specification complete, multi-choice of installation:pipeline, flange tapping, wafer and plug-in.

10.Wide range of nominal diameter: φ15~φ2000 (1/2"~120")or customize.
11.The ability to measure high temperature and high-pressure medium:maximum working temperature 700℃; maximum pressure 42MPa.
12.The ability to measure the dirty medium (coke-oven gas, blast furnace gas, feed stock and residual oil)
13.The ability to measure gas and liquid two-phase medium (moisture and condensed water)

 

 

Product classification and application

1.classification:

A:for installation: Pipe welding, flange , wafer and plug-in.

B:for pressure measurement methods:pressure tap, face flange pressure tappings, plug-in male flange pressure tappings
C:for medium and condition:basic type, high temperature and pressure type, temperature and pressure compensation type, anti-corrosive type and anti-adhesion type.

 

2.Application: metallurgy, chemical industry, Chemical fiber industry, petroleum, nature gas, power supply, Hydraulic, mines, machinery, materials industry , city energy, environmental monitoring.

 

3.Conditions:

nominal diameter: φ15~φ2000, flow rate:≥0.1m/s, working pressure:-0.1MPa~42MPa, working temperature:-160℃~700℃, environmental temperature≤85℃.

 

4.Applicate for many kinds of fluid:

Besides of normal gas ,liquid and steam,it also applicate for all kinds of gas,liquid and steam with high dust ,high suspended solids,high viscosity, strong corrosive,crystallize and supersaturated.

 

5.typical fluid:

gasliquid
Coal-gas:coke oven gas, blast furnace gas, city gasOils:crude oil, fuel oil,emulsified oil, diesel fuel
Nature gas:≥5% moisture content nature gasWater:raw water, drinking water, polluted water
Hydrocarbon gasalkanes, olefinVarious aqueous solutionsacid, lye, brine
Corrosive gases:hydrogen, helium, argon, oxygen
nitrogen
Organic chemicals:methanol,glycol,xylene
Air:hydrous air, dusty air, compressed air  
Flue gas:boiler flue gas,furnace flue gas  
SteamSpecial fluid
Saturated steamOil +HC+sand
Superheated steamH20+CO2 etc.

 

Technical parameters:

Accuracy class:0.5
Long-term stability:± 0.1% F.S / Y
Repeatability:± 0.1%
Minimum flow velocity:0.1m
Turndown ratio:Normally15:1; max50:1
Reynolds number range:8 × 103 ~ 5 × 106
Operating pressure:≤ 16MPa, 42MPa(maximum)
Operating temperature:-160 °C ~ 700 °C
Nominal diameter:φ15~φ2000 (1/2"~120")
Environment temperature:≤ 80 °C
Relative humidity:5 ~ 85%
Output signal:4 ~ 20mA
Power supply:24VDC
Voltage of DP transmitter :24VDC
Current of DP transmitter :4mA ~ 20mA
Voltage of intelligent flow totalizer:220VDC
Current of intelligent flow totalizer:4 ~ 20mA
Communications mode of DP transmitter:HART&BRAIN
Communications mode of smart flow computation indicator:RS232 & RS485

 

Hot Products

Usa Standard Atex Water Sewage Electromagnetic Flow Meter For Liquid Propane HKLD type intelligent ...
Simple Electromagnetic Flow Meter Dn150 Dn400 For Liquid Flow Control HKLD type intelligent ...
Large Dn Magnetic Flowmeter Electromagnetic Flow Meter For Lime Milk HKLD intelligent electromagneti...
Electro Magnetic Dn10 to Pn300 Magnetic Flow Transmitter For Liquid Caustic Soda HKLD intelligent ...
Europe Standard Dn1200 Electromagnetic Flow Sensor Flowmeter Converter HKLD intelligent electromagne...
63mm Dia Intelligent Electromagnetic Flow Meter Dn 100 Brand Metry HKLD type intelligent electromagn...