Wireless Remote Water Meter Monitoring LoRaWAN Smart Water Meter System

Country/Region china
City & Province wuhan hubei
InquireNow

Product Details

LoRaWAN Smart Water Meter Wireless Remote Monitoring Meter for Reliable and Cost-effective Water Management

 

 

  • Product Overview

LoRaWAN IoT water meter is composed of water meter base meter, electric ball valve (valve control), magnetoresistive sensor,
MCU, wireless communication module, control circuit and other components. Mechanical and electrical separation structure design.
High capacity lithium sub battery pack is used for power supply. It provides long-term stable energy guarantee for data acquisition,
valve control and wireless data transmission. LoRaWAN wireless communication module is adopted. Through the spread spectrum communication technology, the user water data is actively uploaded (once a day by default) to the LoRa WAN gateway. The gateway
will upload to the system data service center through LTE 4G network or Ethernet. The system has the advantages of long communication distance, large capacity, fast and convenient installation, long service life, etc.

This water meter is of dry structure. The dry water meter is isolated from the measured water due to its counting mechanism. Therefore,
it is not affected by the suspended impurities in the water to ensure the normal operation of the counting mechanism and the clear reading.
At the same time, it will not, like the wet water meter, affect the reading of the water meter due to the fog or condensation under the glass
caused by the temperature difference between inside and outside the meter.
 
  • Functions and features

1. Split structure: The electronic unit is independent from the base table.

2. Accurate measurement: non-contact full-electronic detection logic is adopted. The metering accuracy is 10 liters.
3. It has the functions of touching the key to wake it up and long press key to go online and transmit data remotely.
4. It has infrared communication interface. Relevant parameters can be read and set.
5. It has alarm functions: Abnormal state battery voltage and valve, continuous small and large flow, metering module failure,etc.
6. Timed collection and upload function:Collect data timed. Auto upload data at the set time point (once a day by default). Meanwhile,
it can receive and execute instructions from the platform.
7. Auto switching of reporting mode: When the on-site signal is abnormal, it will auto switch to monthly mode. While it's recovered,
it will auto resume the daily mode.
8. LP design: 3.6V lithium sub-battery pack (ER26500+HPC1520) is adopted. Sleep current is less than 10uA.
 
  • Specifications & technical parameters
Flow characteristicsComply with GB/T 778.1~3-2007 standard. Accuracy Class: Class 2
Nominal caliber (mm)152025
Overload flow Q4(m3 /h)3.15.07.8
Commonly used flow Q3(m3 /h)2.54.06.3
Maximum allowable errorhigh area (Q2≤Q≤Q4) is ± 2%, the low area (Q1≤Q<Q2) is ± 5%

 

R=Q3/Q1100 (Dry Type) Quiescent current<10uA
Range ratioQ2/Q1=1.6 Q4/Q3=1.25Communication current
 
Data collection and generating currents <50mA,
and peak current <100mA
Pressure loss level△ p≤0.063MPa
Maximum allowable water pressure≤1.2MPaOperating environment0~ +45℃ (cold water),0~95%RH 0~ +90℃ (hot water),0~95%RH
Temperature gradeCold:T30 Hot:T90
Communication mode

LoRaWAN:CN470,RU864,IN865,

EU868,US/AU915,KR920,AS923_

1/2/3/4,Custom Channels

Oprating voltage2.7 ~ 3.6 V

 

  • Display description

In order to prevent malicious people from triggering the water meter online for many times (loss of battery power). We have specifically
set the time interval (5 minutes) between keys triggering the launch, that is, the time interval between two consecutive launches must
be greater than 5 minutes. At the same time, it stipulates that the number of times that a key is pressed to trigger the launch cannot
be greater than 8 times per day (the launch command of infrared communication setting is not affected by this number of times).
 

 

 

 

Hot Products

Single Phase RS485/LoRaWAN/CAT.1 Modbus DIN Rail Smart Prepaid Digital Energy Meter Product ...
Smart Electric Energy Meter: Single & Three Phase, Lorawan/RS485/4G with Prepaid Remote Control and ...
Smart Bluetooth Parent-Child Electronic Energy Meter: Single Phase, LoRaWAN / Nb / 4G / WiFi ...
IOT-based Smart Water Metering Solution for Efficient Water Consumption Management The LXSY-TW type ...
Smart Water Flow Meter with Prepaid Remote Control and Lora/Lorawan/4G, Cold/Hot Flowmeter, DN15...
Smart Ultrasonic Water Flow Meter with Prepaid Remote Control and Lora/Lorawan/4G, Cold/Hot, DN15...