Home Companies HCB Battery Co., Ltd

Lithium Manganese Dioxide Battery Lithium Manganese Oxide Battery CR14505 3 volt lithium cell For Metering

HCB Battery Co., Ltd
Active Member

Contact Us

[China] country

Address: No.1 Special Taizhong Avenue, Gaoqiao Industrial Park, Wujiashan Economic Development Zone, Wuhan, Hubei, China

Contact name:

Inquir Now

HCB Battery Co., Ltd

Lithium Manganese Dioxide Battery Lithium Manganese Oxide Battery CR14505 3 volt lithium cell For Metering

Country/Region china
City & Province wuhan hubei
Categories Other Batteries
InquireNow

Product Details

Lithium Manganese Dioxide Battery, Lithium Manganese Oxide Battery CR14505 3 Volt Lithium Cell For Metering

 

 
Nominal Capacity1500mAh
Battery discharged at continuous current 1mA until voltage reaches cut-off voltage 2.0V at ambient temperature 23±2℃
Nominal Voltage3.0 V
Maximum Continuous Current1000mA
Battery with minimum 50% rated capacity discharged at ambient temperature 23±2℃
Maximum Pulse Discharge Current2000mA
Battery with minimum 50% rated capacity discharged at max pulse for 3 seconds after 27seconds break. Ambient temperature 23±2℃
Storage Condition

Temperature ≤ 30℃

Humidity ≤ 75%RH

Operating Temperature-40℃ to +85℃
Battery DimensionSee drawing on pag
Max Weight21.0g
Self-discharge Rate2%
Max self-discharged rate at ambient temperature 23±2℃
Shelf Life10 years
Ambient temperature 23±2℃
 

 

1. Battery Characteristic

 

  • High Voltage

Each cell nominal voltage up to 3.0V

  • High Energy Density

Specific energy density up to 214Wh/kg

  • Wide Operating Temperature Range

The battery with a strong adaptability to temperature can be in work between -40℃ ~ +85℃

  • Long Shelf Life

The battery self-discharge less than 2% per year at room temperature

 

High capacity, stable performance, stable discharge voltage, and no voltage passivation after long time storage

 

Hermetic welding sealing to reduce the leakage for extending the shelf life to more than 10 years

 

The battery safety performance is good, high reliability, and pollution-free, environmental friendly.

 

2. Main Applications

  • Telecommunications

Wireless telecommunication devices

  • Medical devices

Cardiac pacemaker, respirator, oxygenator, inspection devices, monitoring devices, infusion pump, etc.

  • Tracking

RFID products, road toll transponder, IC cards, etc.

 

3. Manufacturing Advantages

 

  • The technology in HCB is advanced and automatic;
  • Our manufacturing process of cathode is unique and advanced;
  • We can produce high power, high capacity or low temperature batteries and so on;
  • We can provide multiple cascade and parallel connection ways and combining suggestions with our customers if they need;
  • The storage date is over 10 years to prove the reliability of the products.

 

4. Company Advantages

 

  • GB/T19001-2008/ISO9001:2008 is HCB quality management system standard;
  • The Environment Management System in HCB is accord with GB/T24001-2004/ISO14001:2004;
  • We have much experience in drop test package;
  • HCB can provide the report for safe transport of goods to the customers;
  • CE test is available for HCB Battery;
  • Rosh Standard is workable for HCB Battery;
  • UL Standard is workable for HCB Battery;

 

5. FAQS of General Safety Instructions

 

  • How about the storage environment of the battery?

 

The battery should be kept as dryly as possible when they are in storage.

 

  • Is it ok to continue to use the battery when the abnormal heat release or leakage occurs?

 

When the abnormal heat release or leakage occurs, the battery is not able to be continued to use.

 

  • If you have children at home, what should you pay attention when we use our battery?

 

You need to keep battery out of the children. Please call to a physician immediately if it is swallowed by children.

 

  • Why should you keep the batteries away from the fire?

 

They will be hot very fast and can lead the gas and other toxic materials leakage if they are closed to fire.

 

  • What can't you do to the batteries?

 

The batteries are able to be deformed or drilled into or damaged because the toxic materials or gas leakage may lead a big rupture.

 

  • When the batteries are changed, what should you pay attention to?

 

The batteries of different electrochemical system, grades, or brands can’t be mixed because it would lead toxic material or gas leakage and/or a big rupture.

 

  • What will happen if the batteries are thrown into the water?

 

The batteries are not able to put or thrown into the water because it would cause explosion.

 

Hot Products

Long Life 8500mAh Lithium Thionyl Chloride Cell ER26500 Lithium Battery Nominal Capacity 8500mAh ...
3.6V Cylindric Lithium Thionyl Chloride Primary Lithium Battery ER34615+UPC1550 for Smart Metering ...
Lithium Battery , Primary Cell Battery For Temperature Detector International Standard CC Nominal ...
ER26500 Lithium Thionyl Chloride Cell Cylindrical Batteries​ International Standard C Nominal ...
Professional Li SOCl2 Lithium Battery 3.6 V , Lithium Thionyl Chloride Cell Nominal Capacity 3500mAh ...
CR17335SC Lithium Manganese Dioxide Battery No Inner Pressure At Room Temperature 1.Key Features: ...