Lithium Thionyl Chloride High Energy Density Battery ER17335M Long Shelf Life

 

 

 
Nominal Capacity1800mAh
Battery discharged at continuous current 3.4mA until voltage reaches cut-off voltage 2.0V at ambient temperature 23±2℃
Nominal Voltage3.6 V
Maximum Continuous Current340mA
Battery with minimum 50% rated capacity discharged at ambient temperature 23±2℃
Maximum Pulse Discharge Current680mA
Battery with minimum 50% rated capacity discharged at max pulse for 3 seconds after 27seconds break. Ambient temperature 23±2℃
Storage Condition

Temperature ≤ 30℃

Humidity ≤ 75%RH

Operating Temperature-55℃ to +85℃
Battery DimensionSee drawing on pag
Max Weight21.0g
Self-discharge Rate2%
Max self-discharged rate at ambient temperature 23±2℃
Shelf Life10 years
Ambient temperature 23±2℃

 

 

1. Battery Characteristic

 

  • High Voltage

The rated voltage of the single battery is 3.6V, the operating voltage varies with the load, normally between 3.3V and 3.6V

  • High Energy Density

We offer the specific energy density of 308Wh/kg

  • Wide Operating Temperature Range

The battery can be in work between -55℃ ~ +85℃

  • Stable Operating Voltage

Battery voltage is very stable during work, more than 90% of the capacity could be output on a fixed high voltage platform

  • Long Shelf Life

The battery self-discharge less than 2% per year at room temperature

 

Battery sealing using the fully sealed structure to reduce the leakage of the battery, make the battery can be stored at room temperature for more than 10 years

 

2. Main Applications

 

  • Infrastructures

Automatic meters (water meter, electric meter, gas meter), conventional meters, etc.

  • Oil & gas

Well pressure meters in high temperature, float meter, logging while drilling (LWD), measure while drilling (MWD), etc.

  • Medical devices

Cardiac pacemaker, respirator, oxygenator, inspection devices, monitoring devices, infusion pump, etc.

 

3. Manufacturing Advantages

 

  • The technology in HCB is advanced and automatic;
  • We can control the passivation of the battery very well;
  • There are variety of solutions such as high power, high capacity or low temperature etc;
  • We can provide multiple cascade and parallel connection ways and combining suggestions with our customers if they need;
  • There are multiple safety designs for our products.
  • Since 1995, we have started to produce the Li-SOCl2 batteries and we have much experience in it

 

4. Company Advantages

 

  • Quality management system of HCB is conformity with GB/T19001-2008/ISO9001:2008 standard;
  • HCB Environment Management System meets the standard GB/T24001-2004/ISO14001:2004;
  • The battery can pass drop test if you need;
  • Report for safe transport of goods can be provided with you if needed;
  • We can provide you with the CE certificate if you need;
  • Rosh Standard is workable for HCB Battery;
  • UL Standard is workable for HCB Battery;

 

5. FAQS of General Safety Instructions

 

  • In order to keep the battery safely, what should we do?

 

In order to store the battery, the environment should be dry enough.

 

  • Is it ok to continue to use the battery when the abnormal heat release or leakage occurs?

 

The battery should be stopped to using when the abnormal heat release or leakage occurs.

 

  • What is the first step when you would like to use our battery?

 

The manual should be read before the battery is used.

 

  • What should you pay attention for when battery is put into the devices?

 

Follow the signs + and - shown on the batteries and appliances. Do not reverse battery. If batteries are put in the wrong way they are bound to become hot very quickly. This can lead to gas or toxic material leakage and/or to a violent rupture.

 

  • What the danger is if the battery is closed to the fire?

 

The batteries may be incinerated or mutilated if they are closed to the fire and it leads a possible burst or they may release the toxic materials.

 

  • If the positive and negative polarity of a battery is directly connected, what will happen?

 

If + and - polarity of battery is connected directly, it causes a short circuit and this may lead toxic gas and materials leakage or a big rupture.

 

  • Can the batteries be mixed to use on different electrochemical system, grades or brands?

 

When changing batteries be aware that batteries of different electrochemical system, grades, or brands should be not mixed. If different batteries are used or in case of using old and new batteries together this can discharge batteries due to different voltage or capacity. This can cause toxic material or gas leakage and/or violent rupture.

 

Hot Products

Long Life 8500mAh Lithium Thionyl Chloride Cell ER26500 Lithium Battery Nominal Capacity 8500mAh ...
3.6V Cylindric Lithium Thionyl Chloride Primary Lithium Battery ER34615+UPC1550 for Smart Metering ...
Lithium Battery , Primary Cell Battery For Temperature Detector International Standard CC Nominal ...
ER26500 Lithium Thionyl Chloride Cell Cylindrical Batteries​ International Standard C Nominal ...
Professional Li SOCl2 Lithium Battery 3.6 V , Lithium Thionyl Chloride Cell Nominal Capacity 3500mAh ...
CR17335SC Lithium Manganese Dioxide Battery No Inner Pressure At Room Temperature 1.Key Features: ...