Input AC: 200-230V , 50 / 60 Hz. 1 Phase , 2.5 Amp.
SGD-01AN+SGM-01A3NT14 |
SGD-01AHY130 |
SGD-01AS |
SGD-01BH |
SGD-01BP |
SGD-02AH |
SGD-02AHY500 |
SGD-02AN |
SGD-02ANY6 |
SGD-02AP |
SGD-02AS |
SGD-02BH |
SGD-02BP |
SGD-02BS+SGM-02B312 |
SGD-02BS+SGM-02B314 |
SGD-04AN |
SGD-04AN+SGM-04A3NT12 |
SGD-04AP |
SGD-04APY61 |
SGD-04AS |
SGD-04ASY52 |
SGD-04ASY53 |
SGD-08AH |
SGD-08AN |
SGD-08AP |
SGD-08APY61 |
SGD-08ASY25 |
Electrical Shock Hazard
Do not operate equipment with covers removed. Failure to comply
could result in death or serious injury. The diagrams in this
section may show drives without covers or safety shields to show
details. Be sure to reinstall covers or shields before operating
the drives and run the drives according to the instructions
described in this manual. Always ground the motor-side grounding
terminal. Improper equipment grounding could result in death or
serious injury by contacting the motor case.
Do not perform work on the drive while wearing loose clothing,
jewelry or without eye protection. Failure to comply could result
in death or serious injury. Remove all metal objects such as
watches and rings, secure loose clothing, and wear eye protection
before beginning work on the drive.
Do not remove covers or touch circuit boards while the power is on.
Failure to comply could result in death or serious injury.
Do not allow unqualified personnel to perform work on the drive.
Failure to comply could result in death or serious injury.
Installation, maintenance, inspection, and servicing must be
performed only by authorized personnel familiar with installation,
adjustment, and maintenance of AC drives.
Do not touch any terminals before the capacitors have fully
discharged. Failure to comply could result in death or serious
injury. Before wiring terminals, disconnect all power to the
equipment. The internal capacitor remains charged even after the
power supply is turned off. The charge indicator LED will
extinguish when the DC bus voltage is below 50 Vdc. To prevent
electric shock, wait at least one minute after all indicators are
off and measure the DC bus voltage level to confirm safe level.
Fire Hazard Tighten all terminal screws to the specified tightening
torque. Loose electrical connections could result in death or
serious injury by fire due to overheating of electrical
connections. Do not use improper combustible materials. Failure to
comply could result in death or serious injury by fire. Attach the
drive to metal or other noncombustible material
.Do not use an improper voltage source. Failure to comply could
result in death or serious injury by fire. Verify that the rated
voltage of the drive matches the voltage of the incoming power
supply before applying power
Terminals Terminal
Screws Tightening
Torque lb-in (N•m)
Possible Wire Sizes
AWG (mm2)
Recommended Wire Size AWG (mm2)
Wire Type
S1, S2, S3, S4, S5, S6, S7
SN, SC, SP, +V, A1, A2,
AC, MI, M2, M3, M4,
MA, MB, MC, FM, AC,
AM, R+, R-, S+, S-, IG
Phoenix type *3
4.2 to 5.3 (0.5 to 0.6)
Stranded wire: 26 to 16
(0.14 to 1.5) 18
(0.75) • Shielded, twisted-pair wire*1
• Shielded, polyethylene-covered,
vinyl sheath cable
E(G) M3.5 7.0 to 8.8
(0.8 to 1.0) 20 to 14
(0.5 to 2*2) 12 n(1.25)
*1. Use shielded twisted-pair cables to input an external speed
command.
*2. Yaskawa recommends using straight solderless terminals on
digital inputs to simplify wiring and improve reliability.
*3. Yaskawa recommends using a thin-slot screwdriver with a 3.5 mm
blade width.