12V 3000mAh NI-MH Defibrillator Battery For MSC Freiburg CardioServ 30344030 SCP 910/913/915/922 Hellige GE120

 

Specification

 

Item

Rated performance

Note

1.1 Rated Voltage

12V

 

 

1.2 Discharge Cut-off Voltage

8V

 

 

1.3 Rated Capacity

3000mAh

0.2C Discharge

1.6 Standard Charge Current

360mA0.2C

1.7 Quick Charge Current

900mA0.5C

1.8 Max Discharge Current

3000mA-20˚C - +55˚C

1.9 Initial Internal Resistance

≤500mΩ

AC 1kHz (AC Impedance)

1.10 Weight Per Battery

≤345.8g

Electronic scale (W/O Packing Materials)

1.11 Battery Size

L=119 (+0/-0.50mm)

W=98 (+0/-0.50mm)

H=28 (+0/-0.50mm)

Calipers

1.12.Operating Temperature

Charge

0˚C ~+45˚C

Humidity 65±20%

Discharge

-20˚C~+55˚C

Humidity 65±20%

Temperature protection99˚C±5˚C

Humidity 65±20%

1.13 Storage Temperature

Standing Storage

(less than one year

-20˚C~+35˚C

Humidity 65±20%

Notes:

1. Period of storage is counted from shipping date

 

Test

 

1. Testing Environment:

  1.1 Test time should be no more than one month after receive the battery

  1.2 Testing Environment:

Humidity: 15℃--25℃

Relative Humidity: 45%--85%

Atmospheric Pressure: 86kPa--106KPa

 

2. Testing Instrument:

  2.1 Voltage meter 0.5 grade or more regulated by IEC 51/IEC 485, more than 10KΩ/V internal resistance

  2.2 Current meter 0.5 grade or more regulated by IEC 51/IEC 485, include wire resistance less than 0.01Ω.

  2.3 Calipers Definition 0.02mm

  2.4 Internal Resistance Meter AC 1KHz 4 terminal measure setting.

  2.5 Load Resistance Include external circuitry, allowed resistance figure error is ±5%.

  2.6 Finished Battery Product Testing Machine

 

3. Test method and request

Item

Test Method

Request

 

1

Appearance

By sight:30CM vertically

Case appearance should be smooth w/o nick, burr and other mechanical damage. Exposed metallic part should not be

Oxidized. Case should not be distorted.

2

 

Insulation Resistance

Test the external packing of battery and insulation between poles using insulation-meter

More than 10MΩ

3

 

Internal Resistance

AC testing method. In half capacity condition, using AC 1kHz testing method to measure the internal resistance figure between poles in battery connector.

≦500mΩ

4

 

Discharging

1) Use nominal capacity charging method full charge the battery.

2) 1C constant current discharge to 8.0V

Discharging time≥90min

5

 

High temperature Resistant Capability

Put full-charged battery in 55℃±2℃ thermostat for 2h,then use1C discharge to 8.0V

 

    1)After test, 1C capacity should be ≥35min,internal resistance should be no more than 120% of internal resistance before test.

2) Case appearance should not be distorted and crack.

 

6

 

Low temperature Resistant Capability

1) Use nominal capacity charging method full charge the battery.

2). Put full-charged battery in -25℃ ± 2℃ chest freezer for 24h,then use 0.2C discharge to 8.0V

1) After test, 1C capacity should be no less than 70% of it before test,internal resistance should be no more than 150% of internal resistance before test.

2) Case appearance should not be distorted and crack.

 

7

 

Cycle Life

After 300 cycles of complete charge and discharge at 1C current, and record the capacity

Battery should not explode smoke, burn or burst. 1C charge and discharge cycle life should more than 300 times

 

9

 

Fall Proof Capability

Hang the battery in one meter high in the air. Let the cells fall down by six sides

(Anode and Cathode side,crosswise sides)1 time each,all together 6 times.

  1. Battery should not be leak, smoke and burst.

2) After test, 1C capacity should be no less than 95% of it before test. Internal resistance discrepancy should be no more than 3mΩ.

10

 

Capacity Retention

1) In environmental temperature 20℃± 5℃ condition, Use nominal capacity charging method full charge the battery

2) Lay the battery opened circuit 28D, then use 0.2C discharge it to cut off voltage

0.2C discharging time should no less than 3.20H.

11

 

Constant Temperature and Humidity Proof Capability

Lay the battery in temperature 40±2℃ and humidity 90% ~ 95% environmental chambers for 48h. Then lay the battery in environmental temperature 20±5℃condition for 2h. Later discharge it in 1C and record the capacity.

1) Battery appearance should not be obvious nick, leak, smoke and burst.

2) 1C discharging capacity should no less than 93min. Internal resistance discrepancy should be no more than 3mΩ.

 

 

4. Shipping Voltage (Inspection before shipment): ≥12V

 

Protection Capability Test Method and Request

 

Item

Test Method

Request

1

Overcharge Test

Apply 2 times than rated battery voltage and a 2C charge current on the battery for 8hs.

Battery could not be burst, burn, leak and smoke

2

Over discharge Test

Discharge the battery at 1C to cut off voltage,then discharge with loading 30Ω for 24hs.

Battery could not be burst, burn, leak and smoke

3

Pack Short-circuit Protection

  1. The battery is charged to rated capacity.
  2. The battery is to be short circuited by connecting the positive and negative terminals of the battery with thermocouple having a maximum resistance load of 0.3Ω

Battery could not be burst, burn, leak and smoke After charging.

 

 

Detail Image

 

Product Description

 

This battery has been manufactured with high-quality components. It complies with every particular of the orginal manufacturer's regulations and is guaranteed against all manufacturing defects.
If the capacity (mAh) of the replacement battery is higher than that of the original battery, this will allow for a longer usage time.

 

Contact US

 

Big wholesale order is acceptable and the price is negotiable, please contact us for details.
OEM is also welcome. Please tell us the details of the product you want, then we can design and customize it for you.

Do not hesitate to contact us anytime before and after your purchase. If you have any questions on your purchase, please let me know via "contact now" or by email. We will solve it for you.
We are committed to ensuring that you are completely satisfied with every transaction. 100% Satisfaction guaranteed !
We will reply your mail within 24 hours normally. sometimes have a little delay due to the weekends or holidays.
(we work from Monday to Friday (8-17:30 GTM+8)
If you can't get our mail after 48 hours, please check your spam or contact to us. If you email us and I will be on service of you until you are satisfied with your purchase.

 

Hot Products

Battery Maintenance How to charge the battery The battery can be charged by one of two methods: ...
11.1V 4400mAh Li-ion Monitor Battery For Mindray PM8000 PM7000 IPM-9800 Monitor Product Information ...
7.4V 2600mAh Li-ion Monitor Battery For BIS Vista Monitoring System BIS VISTA VTI 14564 Product ...
12V 3000mAh NI-MH Monitor Battery For Burdick EK10 Monitor Product Information Brand Lee&J. Power ...
14.4V 5200mAh Li-ion Monitor Battery For Comen C50 C60 8000D LUTECH datalys 780 Monitors Product ...
7.4V 3700mAh Li-ion Monitor Battery For CONTEC CMS7000 CMS9000 CM8000 CMS8000 Monitor Product ...