Product Details

5000lm 54w Dali dimmable led panel light 60x60cm,Dali driver panel with DALI System

 

1) ETL,TUV,CE,ROHS approved panel light led with 85lm/w 
2) over 85lm per watt 
3) with dimmable funcation DALI Dimming, Dali master, dali system
4) 3 years warrenty

60W 12030 ultra thin LED panel light SAA Approved wholesale dimmable led panel light

LED PANEL LIGHT  weixingtech led panel light

 

Product Features of dali dimming,DALI LED Panel Light:

1.     With External power supply, Driver input voltageAC110/220-240V,50/60Hz; Lighting input voltageDC25-42V,Constant current.

2.     PF>0.95, Power Efficiency: >0.85

3.     Material: AL+PMMA+PC Diffuser

4.     Protection grade IP42; Insulation class II.

5.     Ambient temperature:-20°C~45°C, Surface temperature: 42°C~45°C; Relative humidity 10%-80%RH.

6.     Energy-saving, Super bright, environmental-friendly, saving 65% energy than the traditional panel lights.

7.     Uniform light output, bright and comfortable, alleviating eye fatigue, wide beam angle.

Under the condition of voltage instability, the LED panel light could work properly by using the constant-current LED driver.

 

Specification of 54W 60x60cm DALI dimmable led panel with 3 years warranty 

 

Electrical Data

Rated wattage

54W

Nominal wattage

54 W

Nominal voltage

AC 100-277V

Power factor λ

95%

Operating frequency

50-60 Hz

Energy consumption

45kWh/1000h

Light technical data

Nominal luminous flux

5501 lm

Rated luminous flux

4401lm

Color temperature

2800-3200K

Light color as per EN 12464-1

Warm white

Color rendering index CRI

85

Standard deviation of color matching

≤3 sdcm

Starting time

≤0,1 s

Warm-up time (60 %)

0,0 s

Lumen main. fact. at end of nom. life time

70 % min.

Lumen maintenance at end of service life

70 % min.

Farben & Materialien

mercury and lead-free

Yes

Lifespan

Nominal lamp life time

50,000 hours

Rated lamp life time

40,000 hours

Switching cycles (on/off)

100,000

Additional factor

Installation type

Recessed/Suspended/Surface mounting

Capabilities

Dimmable (standard power adapter)

No

Dimmable (dimmable power adapter)

Yes ,dali driver, Dali dimmable Driver

Certificates & standards

Energy efficiency class

A+

Dimensions

Actual Size

595*595mm

Thickness

10mm

Packing Size

71*71*25cm/CTN

G.W

25kgs

DALI   Dimming

DALI  Digital Addressable Lighting Interface

DALI is an International Standard (IEC 62386) for the control of electronic ballasts, transformers, LED’s, emergency lights and exit signs in an easy to manage digital lighting control system.

DALI provides benefits for:
Designers & ConsultantsInstallers & Electrical ContractorsSystem IntegratorsBuilding Occupants & TenantsFacility ManagersBuilding Owners

Knowledge of DALI sytem

IEC 60929 and IEC 62386 are technical standards for network-based systems that control lighting in buildings. They were established as a successor for 0-10 V lighting control systems, and as an open standard alternative to Digital Signal Interface (DSI), on which it is based. IEC 60929 is the first version of the standard and will be withdrawn by 23rd of June 2014. Members of the AG DALI are allowed to use the Digital Addressable Lighting Interface (DALI) trademark on devices that are compliant with the current standard. Non AG DALI members can apply for a fee bearing licence.
A DALI network consists of a controller and one or more lighting devices (e.g., electrical ballasts and dimmers) that have DALI interfaces. The controller can monitor and control each light by means of a bi-directional data exchange. The DALI protocol permits devices to be individually addressed and it also incorporates Group and Scene broadcast messages to simultaneously address multiple devices (e.g., “Group 1 goto 100%” or “Recall Scene 1″).
Each lighting device is assigned a unique static address in the numeric range 0 to 63, making possible up to 64 devices in a standalone system. Alternatively, DALI can be used as a subsystem via DALI gateways to address more than 64 devices. Data is transferred between controller and devices by means of an asynchronous, half-duplex, serial protocol over a two-wire differential bus, with a fixed data transfer rate of 1200 bit/s.
DALI requires a single pair of wires to form the bus for communication to all devices on a single DALI network. The network can be arranged in a bus or star topology, or a combination of these. The DALI System is not classified as SELV (Separated Extra Low Voltage) and therefore may be run next to the mains cables or within a multi-core cable that includes mains power. The DALI data is transmitted using manchester encoding and has a high signal to noise ratio which enables reliable communications in the presence of a large amount of electrical noise. DALI employs a diode bridge in the interface circuitry so that devices can be wired without regard for polarity. Signal level are defined as 0±4.5 V for “0″ and 16±6.5 V for “1″.[1] Central interface power maximum is 250 mA and 2 mA per unit.[1] The network cable is required to be mains-rated, with 600 V isolation and at least a 1 mm cross-section, with a maximum drop of 2 volts along the cable (max 300 m).[1] Signal interface is galvanically separated and doesn’t need any termination resistors.
Earlier generations of DALI devices stored configuration data in EEPROM, which was problematic due to the limited number of write cycles supported by EEPROMs. In current generations of DALI devices, RAM is used in preference to EEPROM during normal operation, which significantly reduces the number of EEPROM writes and thus extends their lifetimes. This use of RAM, however, is patented and therefore mandates payment of a license fee.

DALI is a dedicated protocol purely for lighting control. This means that DALI cannot be used to control other systems such as BMS. 

However, DALI is effective for scene selection and for getting feedback regarding faulty light sources. This makes it very useful to use together with building automation systems where remote supervising and service reports are required.

SYSTEM DESCRIPTION

MAIN DALI FEATURES AND BENEFITS COMPARED TO 1-10V ANALOGUE CONTROL SYSTEMS

Individual control of fittings: each unit in the DALI network has it´s own individual address, therefore it is possible to communicate directly to the components in the fittings
Multichannelling use: through only one pair of control cable it is possible with DALI to control several different groups of fittings
No mains switching needed: the lights can be switched off by commands comming directly from the DALI control system making the mains switch unnecessary
Backchannelling: the information flow is bidirectional with the DALI system. Instead of only giving commands about the light level to the fitting DALI system enables also information feedback on the condition of the fittings. the fitting can transmit information about
whether the light is switched on or off,
the preset light level
the ballast condition
simple DALI wiring: the cabling consists of a simple two wire cable, independent of any building topology between the units in the system
Easy system re-configuration: once the system is installed and configured it is very easy to change the functioning of the system, changing of scenes and functions of lighting is only a matter of programming and needs no hardware changes anymore
easy to add new components: when the lighting system needs to be enlargened new components can be added anywhere in the DALI system, no wiring configuration rules apply on the DALI line in this aspect.
MAIN DIFFERENCES BETWEEN DALI AND BUILDING AUTOMATION BUSES

DALI has a limited system size (64 addresses).
DALI is meant only for communication in lighting systems as BMS includes other functionality as well (HVAC, alarm systems…)
A BMS system commonly has unlimited expansion possibilities, which DALI does not have
DALI is not competing against BMS systems, it is only complementing them through an interface

 

 

 

Hot Products

Bridgelux 45mil Chip Outdoor Led Flood Lights 150W with Meanwell Driver Parameter: Input Voltage AC ...
Bridgelux Chip 100w Led Flood Lights 2700k - 6500k For Outdoor Lighting PRODUCT Feature: 1. Led chip...
Dimmable Bridgelux 70w Brightest Outdoor Led Flood Lights 6000k CCT Features: 1. Adopted optical ...
11000LM High Wattage Cree Outdoor Led Flood Lights Football Ground Led Floodlight SPEC of ZLONE led ...
Warm White High Output 100w Led Floodlight For Football Court Features 1.They are CE RoHS certificat...
Commercial Landscape Led Flood Lamp 50/60hz IP65 Led Flood Light Features 1.They are CE RoHS ...