Home Companies Henan Lanphan Industry Co.,Ltd

H2600mm 18kw Bho Falling Film Vacuum Evaporator

Henan Lanphan Industry Co.,Ltd

Contact Us

[China] country

Trade Verify

Address: 13 Jinjiang South Road, Shangjie District, Zhengzhou City, Henan Province

Contact name:admin

Inquir Now

Henan Lanphan Industry Co.,Ltd

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

H2600mm 18kw Bho Falling Film Vacuum Evaporator

Country/Region china
City & Province zhengzhou henan
InquireNow

Product Details

 

Lanphan Ethanol Continuous Multiple Effect Bho Falling Film Vacuum Evaporator Price For Industrial

 

Product Description

 

This falling film evaporator is widely used in the concentration of chemical, ketchup, glucose, starch sugar, oligosaccharide, caramel, sorbitol, fresh milk, fruit juice, vitamin C, maltodextrin, pharmaceutical and other aqueous solutions. Besides, it is also widely used in the waste liquid treatment of monosodium glutamate, alcohol, fish powder and other fields.

 

The equipment is continuously operated under vacuum and low temperature conditions, with high evaporation capacity, energy saving and consumption reduction, low operating cost, and it can maintain the original color, aroma, taste and ingredients of the processed materials to the maximum extent.

 

It is widely used in many industries such as food, medicine, food deep processing, beverage, light industry, environmental protection, chemical industry and other fields.

 

The falling film distillation belongs to a liquid film concentrating device, which has a high heat transfer rate and a short heating time.

 

The theory is that the feed liquid is added into the evaporation chamber. Under the action of vacuum and gravity, the accelerating head of the liquid is smaller than the accelerating head of the ascending film type, and the boiling point is also small. There is a big temperature difference between the electric heating and the feed liquid, so the heat transfer effect is better. The steam enters the evaporation separation chamber for separation. The secondary steam is discharged from the top of the chamber and the concentrate is discharged from the bottom.

 

Operation Procedures


1. The first step is to remove the gas in the equipment to create a vacuum environment and after the vacuum degree is enough, feed water in replacing materials. When water is running smoothly (the water in the evaporator increases with the increasing in walk, surface evaporation indoor materials are not higher than sight glasses), open circulating pump, cooling water is piped in, start the heating tube and start the discharge pump. After the equipment runs well, adjust throttling components in each position according to the the random process flow chart of the equipment. Then replace the material with water for running. When the vacuum degree and temperature difference meet the requirements, replace the material with water for running for more than 4 hours. It is qualified if the evaporation capacity meets the requirements; otherwise, adjust the throttle element again.
2. Firstly start the vacuum pump. If it is a water ring vacuum pump, the water ring vacuum pump should be started at no load. After the water ring vacuum pump is running normally, the working water valve of the water ring pump is opened. When the vacuum and temperature difference of each effect reach the required level, water should be used instead of the material to start the operation and start the condensate. After the water is cut off, the material is put into the material tank. The sampling valve is initially opened, the water is discharged, and the material that does not meet the concentration requirement is placed in the tank. When the discharge concentration requirement is reached, the discharge valve is opened, and the sampling valve on the material tank is closed, and the equipment is put into normal operation.
3. During the operation of the pump and before starting, it should be observed that the cooling water of the mechanical seal of the pump must not be interrupted, so as not to damage the mechanical seal of the pump.
4. When the work is to be stopped, water is used instead of the material to replace the materials in the equipment and its piping to prevent the material from crystallizing or solidifying in the equipment and its piping. When the ambient temperature of the equipment is below 0 °C, the water in the equipment and its pipeline should be drained to avoid freezing or blocking the pipeline.
5. When parking due to accidents such as sudden power failure, immediately close the valve, release the materials stored in the equipment and its pipeline as soon as possible, or dilute the heated water until it does not crystallize or solidify. When there is material in the equipment and its pipeline, the material pump should be started first to make the material run smoothly when starting the vehicle, and then the vacuum pump is started.
6. During the operation, if the degree of vacuum is low, especially after restarting after accidental parking caused by power failure and so on, immediately find out if there is leakage at the flange and the joint, and block the leak in time.
7. The cleaning of equipment:After the equipment is finished, the equipment and its pipelines are washed and cleaned with water, 1-2% NaoH aqueous solution, clean water, 1-2% HNO3 aqueous solution and clean water. The pump is pumped with the above washing liquid, and each washing liquid should not be less than 10 minutes.


The equipment should not be washed by using hydrochloric acid or hydrochloric acid chloride-containing aqueous solution during scouring or cleaning to avoid intergranular corrosion of stainless steel equipment and affect the service life of the equipment.

Name Electric heating single effect falling-film evaporator
Model LXQX - 5-00
Evaporation capacity 5kg/h
Total power 18kw
Cooling water consumption 1T/h (inlet 25°C, outlet 35°C)
Boundary dimension 1600x900x2600mm
Equipment configuration list heater, evaporator, feed pump, vacuum pump, condenser, equipment support, material pipeline, etc.

 

 

Care and Maintenance


1. Always check whether the oil cup of the pump is short of oil, and whether the cooling water in the mechanical seal is broken.
2. Always check the flanges and joints of the equipment for air leakage.
3. When the mechanical seal of the pump is damaged, it should be replaced in time.
4. When the check valve rubber ball and rubber gasket are damaged, they should be replaced in time.
5. If the indications such as thermometer, vacuum gauge, pressure gauge, etc. are inaccurate, they should be proofread or replaced in time.
6. The surface of the equipment should not be rubbed with a hard scrubbing tool (such as steel brush) to avoid scratches and scratches on the stainless steel surface.

Company Information

Our Services

Pre-sale Service 

1. Provide 24-hour technical consulting reply;
2. Provide professional quoted price;
3. Provide detailed product performance specification;
4. According to product’s using condition, technicians will offer rationalization proposals to assist clients to select proper product types;
5. Provide other corollary equipment according to client requirements.

In-sale Service 

1. Begin to supervise from raw material, its qualified rate can reach to 100%;
2. Whole manufacturing process are in strict accordance with promised procedure requirements, product qualified rate can reach to 100%;
3. Provide product’s inspection record of key junctures to customers;
4. Provide production schedule photos to customers at regular intervals;
5. Package and transport products strictly accordance with export standard;
6. Provide transportation schedule information to clients timely.

After-sale Service

1. Provide targeted installation video;
2. Under the premise of correct installation, normal maintenance and using, we guarantee one-year warranty period;
3. When warranty period has expired, our sold products enjoys lifetime guarantee repair, we only charge cost price for changing product’s standard component and sealing component;
4. During installation and adjustment period, our after-sale service staff will communicate with customers frequently to know product’s running state in time. Assist customers to install and adjust products until customers are satisfied;
5. If product has malfunction during operation period, we’ll offer you satisfied answer in time. We’ll reply you within 1 hour and provide solution or send staff to spot within 24 hours after receiving maintenance notification;
6. Lifelong free technical support. Conduct satisfaction survey and inquiry equipment running condition to clients by telephone or e-mail semiannually from the first day of equipment running, put on records of acquired information;
7. Provide assistant service if product is damaged during transportation.

Hot Products

Steam Distillation Essential Oil Perfume Extraction Rotary Evaporator Product Description A rotary ...
Laboratory Industrial Glass Vacuum Flash Rotary Evaporator Product Details 1. Evaporation Flask The ...
Steam Distillation Essential Oil Perfume Extraction Rotary Evaporator Product Features 1. Better ...
Lab Scale Rotary Evaporator For Pilot Plant 5L Rotary Evaporator Advantages 1.Manual up and down ...
Steam Distillation Lab Rotary Evaporator Essential Oil Perfume Extraction Equipment Rotary ...
RE-501 Rotary Evaporator High Efficiency Heating Equipment Rotary Evaporator Advantages 1. Smooth ...