Home Companies Hai Da Labtester

HPLC Gas Chromatography Testing Machine Used For Quantitative And Qualitative Analysis

Hai Da Labtester

Contact Us

[China] country

Trade Verify

Address: Room 105, Building F4, District F, Tianan Digital City, Nancheng District, Dongguan City, Guangdong Province,China

Contact name:Lisa

Inquir Now

Hai Da Labtester

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

HPLC Gas Chromatography Testing Machine Used For Quantitative And Qualitative Analysis

Country/Region china
City & Province dongguan guangdong
Categories Gas Disposal
InquireNow

Product Details

HPLC Gas Chromatography Testing Machine Used For Quantitative And Qualitative Analysis

 

 

Product Description:

Gas chromatograph is used for quantitative and qualitative analysis to determine the physical and chemical constants such as the distribution coefficient, activity coefficient, molecular weight and surface area of the sample in the fixed phase. An instrument for analyzing the components of a mixed gas.

 

Column temperature Box
Furnace Size28×30×18cm
Temperature control RangeAbove room temperature5℃~450℃;Using liquid nitrogen cold traps:-80℃~400℃;Using dry ice traps:-55℃~400℃
Temperature setting accuracy0.1℃
Maximum program heating rate120℃/min
Maximum once method run time999.99min
Program temperature maximum order7 stages
Program heating rate0.1~120℃/min(Incremental 0.1℃)
Operation Column loss compensation (dual channel)
Heating Zone
6 independent control Heating zone control (excluding furnace temperature, two inlet, two detectors, two auxiliary heating area auxiliary heating zone maximum operating temperature )
 300℃
Detectors
Hydrogen Flame Ionization detector FID
Maximum operating temperature450℃
Minimum detectable limit≤2.5pgC/s [n-C16]
Dynamic linear range≥107(±10%)
Data acquisition frequencyThe highest: 100Hz
Thermal conductivity cell detector TCD
Maximum operating temperature400℃
Minimum detectable limit<400pg C3H8/ml(He)
Dynamic linear range105(±5%)
data acquisition frequencyThe highest: 100Hz
Flame photometric detector FPD
Maximum operating temperature250℃
Minimum detectable limit<4pgC/sec,<1pg P/sec
Selective105gS/gC,106gP/gC
Dynamic linear Range>103S,>104P
Electronic Capture Detector ECD
Maximum operating temperature400℃
Detector compensation Gas Type5% Methane/Argon or nitrogen
Minimum detectable limit<0.01Ppg/s lindane
Dynamic linear range>5×1055
data acquisition frequencyMax 100Hz
Radioactive sources<12mCi 63Ni
Nitrogen and phosphorus detectors NPD
Maximum operating temperature450℃
Minimum check out limit<0.2 pg N/sec,<0.2 pg P/sec
Dynamic linear Range105N,105P
Minimum detection limit<0.3pg C/Sec
The above detectors are suitable for filling column and capillary column
Optional configuration
Anti-control softwareAutomatic Feed b6891n

 

The table parameters is for the company Standard Model parameters, we support customer customization parameters

 

Advanced Power Distribution Management shunt

A 3000 watt UPS can provide 10 units of normal power 2250 watts/set of GC stable working power supply

 

Automatic Feed

8-bit automatic injection device (optional Agilent 7683/7693 liquid automatic injection)

With Automatic online detection function

 

Precision temperature control of the heating furnace

Furnace internal control accuracy less than 0.01°c

The temperature difference between the internal points is not more than the °c

Rapid heating and cooling, the highest program heating speed: 120℃/min, balance time 10 seconds, cooling time 300°c~50°c 6 minutes Absolute control of the temperature accuracy (with the actual temperature difference is less than 0.3C)

 
Gas Chromatography

 

Why Choose Us?

1. Considerate Service Different countries plugs, manually change the-voltage from 110V to 220V, insurance indicator.

2. Excellent After sale Service:

18 months warranty. Besides, we can help you to repair your problem controller freely, even it's not from our factory. What you need to do is to send us the controller.

3. Commitment:

We will sign a letter of commitment while we sign the contract, which will improve your confidence to us.

4. Good Packaging:

Simulation Animatronic Customer Triceratops are covered with air bubble film before put them into the wooden case, which not only has good shock absorption, impact resistance, heat sealing and also has the advantages of nontoxic, odorless, moisture corrosion, good transparency etc.

 

Hot Products

Anti-yellowing Accelerated Aging Test Chamber With Automatic Controller HD-E704 Anti-yellowing Aging ...
Accelerated Anti Yellowing Aging Test Chamber With Temperature Control HD-E704 Anti-yellowing Aging ...
ASTM Standard UV Accelerated Aging Test Chamber With Programmable Controller HD-E802 UV Aging ...
UV Anti-Yellowing Aging Test Chamber General Specification Packaging Dimensions: (W*D*H): 134*90...
UV Light Accelerated Aging Environmental Test Chamber Generl Specifications Packaging Dimensions: ...
Programmable Simulated UV Environmental testing machine UV aging equipment Applications 1. To get ...