Home Companies Hai Da Labtester

Automatic Sampling Gas Chromatograph Lab Test Machines With PID Detector

Hai Da Labtester

Contact Us

[China] country

Trade Verify

Address: Room 105, Building F4, District F, Tianan Digital City, Nancheng District, Dongguan City, Guangdong Province,China

Contact name:Lisa

Inquir Now

Hai Da Labtester

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

Automatic Sampling Gas Chromatograph Lab Test Machines With PID Detector

Country/Region china
City & Province dongguan guangdong
InquireNow

Product Details

Automatic Sampling Gas Chromatograph Lab Test Machines With PID Detector

 

Product Description:

Automatic sampling gas chromatograph is used for quantitative and qualitative analysis to determine the physical and chemical constants such as the distribution coefficient, activity coefficient, molecular weight and surface area of the sample in the fixed phase. An instrument for analyzing the components of a mixed gas.

 

Application industry

1. Analysis of dissolved gas in transformer oil;

2. Analysis of ethylene oxide in medical devices.

3. Analysis of coke oven gas;

4. Pesticide residue analysis;

Alcohol analysis in blood; 5.

6. Analysis of natural gas and liquefied gas;

7. Indoor environment TVOC analysis;

8. Analysis of liquor components;

9. High purity gas analysis;

10. Detection of solvent residue of packaging materials.

 

 

Column temperature Box
Furnace Size28×30×18cm
Temperature control RangeAbove room temperature5℃~450℃;Using liquid nitrogen cold traps:-80℃~400℃;Using dry ice traps:-55℃~400℃
Temperature setting accuracy0.1℃
Maximum program heating rate120℃/min
Maximum once method run time999.99min
Program temperature maximum order7 stages
Program heating rate0.1~120℃/min(Incremental 0.1℃)
Operation Column loss compensation (dual channel)
Heating Zone
6 independent control Heating zone control (excluding furnace temperature, two inlet, two detectors, two auxiliary heating area auxiliary heating zone maximum operating temperature )
 300℃
Detectors
Hydrogen Flame Ionization detector FID
Maximum operating temperature450℃
Minimum detectable limit≤2.5pgC/s [n-C16]
Dynamic linear range≥107(±10%)
Data acquisition frequencyThe highest: 100Hz
Thermal conductivity cell detector TCD
Maximum operating temperature400℃
Minimum detectable limit<400pg C3H8/ml(He)
Dynamic linear range105(±5%)
data acquisition frequencyThe highest: 100Hz
Flame photometric detector FPD
Maximum operating temperature250℃
Minimum detectable limit<4pgC/sec,<1pg P/sec
Selective105gS/gC,106gP/gC
Dynamic linear Range>103S,>104P
Electronic Capture Detector ECD
Maximum operating temperature400℃
Detector compensation Gas Type5% Methane/Argon or nitrogen
Minimum detectable limit<0.01Ppg/s lindane
Dynamic linear range>5×1055
data acquisition frequencyMax 100Hz
Radioactive sources<12mCi 63Ni
Nitrogen and phosphorus detectors NPD
Maximum operating temperature450℃
Minimum check out limit<0.2 pg N/sec,<0.2 pg P/sec
Dynamic linear Range105N,105P
Minimum detection limit<0.3pg C/Sec
The above detectors are suitable for filling column and capillary column
Optional configuration
Anti-control softwareAutomatic Feed b6891n

 

The table parameters is for the company Standard Model parameters, we support customer customization parameters

 

Accurate furnace temperature tracking design

 

Independent Heating small column box In the multi-column chromatographic system, the temperature of different columns can be set respectively, so as to achieve the best separation effect of each column.

 

Fully imported Valve configuration system Up to 8 valves (four-pass valve, six-pass valve, ten-pass valve and liquid injection valve optional); Automatic control, sequence operation;

 

Pneumatic cutting technology for the convenience of implementation

Multi-dimensional chromatographic function to complete the separation and analysis of complex samples It can realize the inverse blowing function of chromatographic column to save the analysis time and cycle greatly.

 

gas chromatograph

 

gas chromatograph

 

 

FAQ

Q:Are your company a trading one or a factory?

A:Factory + trade (integration),More than 12 years focusing on test equipment field,6 years exporting experience.

Q:After an order is placed, when to deliver?

A:Generally about 10-25days, If we have inventory, we can arrange shipment within 3 days.

Please be aware that our production lead times depend on specific items and item quantities.

Q:What about the warranty with after - sales services?

A:The testing machine is guaranteed for 12 months by HAIDA,we can help you to repair

your problem controller freely,even it's not from our factory. After the warranty, the professional after-sale service team will provide perfect technical support and help guests solve problems encountered while using our product, handles guest problems and complaints in a professional and timely.

Q:What about the product' services and quality?

A:Each equiopment must be carried out 100% quality examination and test when shipping and delivery goods. Product use training, each of our product provide video training to show you how to install & operate. We can arrange engineer to train the operation of equipment to customer's company when you need. products are widely recognized and trusted by users.

 

 

Hot Products

Anti-yellowing Accelerated Aging Test Chamber With Automatic Controller HD-E704 Anti-yellowing Aging ...
Accelerated Anti Yellowing Aging Test Chamber With Temperature Control HD-E704 Anti-yellowing Aging ...
ASTM Standard UV Accelerated Aging Test Chamber With Programmable Controller HD-E802 UV Aging ...
UV Anti-Yellowing Aging Test Chamber General Specification Packaging Dimensions: (W*D*H): 134*90...
UV Light Accelerated Aging Environmental Test Chamber Generl Specifications Packaging Dimensions: ...
Programmable Simulated UV Environmental testing machine UV aging equipment Applications 1. To get ...