CPAP BiPAP S/T Non invasive respiratory machine portable medical ventilator

Y series BPAP Systems are Bi-level PAP (Bi-level Positive Airway Pressure) devices intended to
provide non-invasive ventilation for patients with Obstructive Sleep Apnea (OSA) and Respiratory
Insufficiency. They are intended for adult patients by prescription in the home or hospital/institutional
environment. With its Target Tidal Volume function and other excellent comfort features and effective
performance, it offers each patient personalized ventilation support.

Model Comparison

Y-30TIPAP: 4 -30 hPa
EPAP: 4 -25 hPa
C PAP m ode: 4 -20 hPa
3.5-inchCPAP, S, T, S/T
 

 

 

Specification

NameY-30T non invasive ventilators
Pressure range4-30cm H2O(±0.5cm H2O)
Pressure accuracy±0.5cm H2O
Delayed boost0-60min, set the division interval 5min
Initial pressure4cm H2O treatment pressure / respiratory pressure setting
Therapeutic pressure4-20cm H2O (in CPAP mode)
Target tidal volume150ml - 1500ml, on / off
Maximum suction pressure4-30cm H2O, (can be set when the target tidal volume funct
Minimum suction pressure4-30cm H2O (not higher than suction pressure)can be set
Inspiratory phase pressure4-30cm H2O
Expiratory pressure4-30cm H2O
Inspiratory time0.3-3.0s
backup rateOn / off, default 10


Ramp
The ramp time ranges from 0 to 60 minutes
Humidifier
Humidifier Settings: off, 1 to 5 (95°F to 167°F
/ 35°C to 75°C)
Humidifier Output: No less than 10 mg H2O/L
SpO 2
Range: 0 to 100%
Pulse Rate
Range: 40 to 240 BPM
Sound Pressure Level
< 30 dB, when the device is working at the pressure of 10 hPa
Storage
SD card can record patient data and fault information
AC Power Consumption
100 - 240 V AC, 50/60 Hz, Max 2 A
Key Parameters
Target Vt: On/ Off
150~1500 mL
Reslex: Patient, Off, 1~3
I Sens.: 1~8
E Sens.: 1~8
Res Rate: 3~40 BPM
Ti: 0.3-3.0s
Rise Time: 1~4

Hot Products

16 CFR1633 Mattress Heat Emission Tester Product introduction CFR 1633 Mattress Heat Emission Tester...
Calorimeter System for Mattresses, Upholstered Furniture and Stacked Chairs Product introduction ...
ASTM E1623 Intermediate Scale Calorimeter 1.Product Introduction Intermediate Scale Calorimeter,used ...
FAA Aircraft Materials Fire Test Handbook, Chapter 5 Tester for Rate of Heat Release OSU Heat ...
FMVSS 302 Horizontal Flammability Tester Product introduction The instrument consists of two parts: ...
Textile Fabrics Vertical Fire Testing Equipment CFR 1615/1616 For Knitted Fabric Standards CFR 1615...