Home Companies SKYLINE INSTRUMENTS CO.,LTD

IEC60331-11:19999 Over Current Fire Testing Equipment For Wires And Cables Resistance To Fire

SKYLINE INSTRUMENTS CO.,LTD

Contact Us

[China] country

Trade Verify

Address: No.1802 Room 6# Building Universal Commerce Center Nancheng District Dongguan Guangdong China

Contact name:Ivy Xie

Inquir Now

SKYLINE INSTRUMENTS CO.,LTD

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

IEC60331-11:19999 Over Current Fire Testing Equipment For Wires And Cables Resistance To Fire

Country/Region china
City & Province dongguan guangdong
Categories Solar Chargers
InquireNow

Product Details

Over-current Flammability Testing Equipment For Wires and Cables Resistance to Fire
 
Application
Applies to check the test integrity of the circuit for wires or cables, use to check the flame retardant properties of insulating refractory characteristics of cable and wires and cables with fireproof layer under overheating, over-current, etc abnormal condition.
 
Standards
According to  IEC60331-11:19999, IEC60331-21:1999, IEC60331-23:1999, IEC60331-25:1999,  and BS6387
 
Technical parameters
 Ribbon burner 500m for length of nozzle, 15mm for width of nozzle. Number of the hole of 1.32mm diameter is totally 470
 Gas flow range 1-10L/min; glass rotor flow meter indicates the current flow, Using propane gas or liquefied petroleum gas (LPG)
 Area flow range 10-100L/min, glass rotor flow meter indicates the current flow
 Position of burner Burner center horizontal at 70±10mm under the specimen lowest point, nozzle at 45mm distance from the specimen center vertical
 Specimen supported 150mm for inner diameter of metal ring, using 12mm stainless steel materials.NO:5
 Thermocouple K type thermocouple with stainless steel sheathed, which diameter is 1.5mm and according to GB/T 16839.1
 Temperature calibration 2pcs of thermocouples display data average value between 750+50-10℃required in 10 minutes, and difference value between average value and either of the two thermocouple’s display data cannot over the 40℃
 Test power Output voltage is AC0~1000V and output current is AC0.01-0.70A, four circuits adjustable independent
 Burning time 0~999.9S/ M/H adjustable
 Laboratory 27m3

 

 

What is a test fire and why is it important?
What Is Fire Testing? Fire testing intends to understand the influence of a direct flame on a material or product. Companies may analyze the effect on wiring or cable, building materials or furnishings.

 

 

Hot Products

Flammability Testing Equipment , Tracking Index Tester Used range This machine applies to determine ...
220V / AC 50Hz Flammability Testing Equipment Needle Flame Tester Use It used to determine ...
3500W NBS Plastic/ Rubber Smoke Density Testing Machine ISO 5659-2:2006 Product Description (note: ...
ISO 5659-2 Plastic Smoke Density Testing Machine Overview The plastic burning smoke density tester ...
Automotive Interior Material Vertical Combustion Tester Product introduction According to the ...
ISO 5660 Cone Gauge Calorimeter Application The oxygen consumption calculated from the oxygen ...