Product Details

Low Temperature Bending Test Machine

 

 

Introduction

It is suitable to examine and test the performance under low temperature for circular insulating core wire under Φ12.5m and Sector Insulated Wire Core which can not make Dumbbell test specimen(Shorter axis of sheath≦20mm flat cable).

 

Reference standards

● GB2951.14-2008, Sect 8.1&8.2 Common test methods for insulating and sheathing materials of electric and optical cables - Part 14: Methods for general application - Test at low temperature

● IEC60811-1-4:2001 INSULATING AND SHEATHING MATERIALS OF ELECTRIC CABLES - COMMON TEST METHODS - PART 1-4: GENERAL APPLICATION - TESTS AT LOW TEMPERATURE

● JB/T4278.11-2011 Verification procedure for test equipment of rubber plastic wire and cable.

 

Technical specifications

1

Test groups

two groups

2

Dimension

420L*400W*300H(mm)

3

Diameter of specimen

Φ2.5~Φ12.5mm

4

Outlet diameter of guiding tube(mm)

Φ1.2,Φ2.4,Φ3.0,Φ3.8,Φ4.7,Φ5.9,Φ7.4,Φ9.2,Φ11.5,Φ14.5,totally 10 groups confirms to JB/T4278.11-2011

5

Diameter of winding rod

Φ4,Φ5,Φ6,Φ7,Φ8,Φ10,Φ12,Φ14,Φ16,Φ18,Φ20,Φ24,Φ28,Φ32,Φ36,Φ40,Φ45,Φ50mm,totally 18 pieces conforms to JB/T4278.11-2011(it can also be customized)

6

Winding mode

adjust speed manually

7

Material

SUS304

 

 

Related Products

 

Hot Products

ISO 8142 Thermal Insulation Materials Maximum Use Temperature Test Apparatus Introduction: This ...
Lateral Flame Spread Testing For Walls Surfaces Introduction Lateral Flame Spread Testing Equipment ...
Fire Propagation Index Testing Equipment for Laminated Foil BS476-6 FPT.pdf Introduction: BS 476-6 ...
ISO9239 FRPT.pdf Introduction: Critical Radiant Flux is the main parameters of the fire risk for ...
Introduction This Fire Test Equipment is developed base on the standard AS1530.2, test for ...
Introduction: The BS 476-12 Ignitability Tester is designed according to the BS476-12:1991. Method ...