Home Companies Advanced Instruments Co.,Limited

Laboratory Binary HPLC System High Performance Liquid Chromatography

Advanced Instruments Co.,Limited

Contact Us

[China] country

Trade Verify

Address: Hi-tech Developing Industrial Area, Liuyang City,Changsha,Hunan Province,China

Contact name:Sandy

Inquir Now

Advanced Instruments Co.,Limited

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

Laboratory Binary HPLC System High Performance Liquid Chromatography

Country/Region china
City & Province changsha hunan
InquireNow

Product Details

 

Binary HPLC System High Performance Liquid Chromatography

P3100 High Pressure Constant Flow Pump
◆ Flow rate range: 0.001-10.000 mL/min, in 0.001 mL increments
◆ Flow accuracy: ≤±0.2% (1.00ml/min, H2O,R.T.,8.5MPa)
◆ Flow precision: RSD≤0.06% (1.00ml/min, H2O,R.T.,8.5MPa)
◆ Maximum pressure: 45MPa

 

 

UV3100 UV/VIS Detector

Wavelength range190-700 nm
Wavelength repeatability≤0.1 nm
Wavelength accuracy≤±1.0 nm
Bandwidth8nm
Response time0.0 s-5 s
Baseline noise≤±0.5×10-5 AU
Drift≤1.0×10-4 AU/h (empty cell, 254 nm, 60 min)
Path length10 mm(analytical cell)
Light sourcwDeuterium Lamp

 

 

Chromsoft Chromatographic Data-processing Workstation

◆ Internal and external standard calculation methods
◆ Automatically displays, prints, exports and starts other programs after the completion of a measurement.
◆ Comply with the requirements of the 21 CFR Part 11 directive of the FDA

 

 

Eclassical 3100 System Kits

◆ Containing required tubing, fittings, wreches and cables for system.
◆ C18 column 5μm ID4.6×200mm
◆ 7725i manual injector
◆ TD-1-15 mixer
◆ User manual

 

 

RI-201H Refractive Index Detector

◆ Flow cell type:2 chamber-type
◆ Measuring method:Deflection type
◆ Refractive Index range:1.00 to 1.75
◆ Measuring range:0.25 to 512μRIU
◆ Drift:0.2μRIU/h (Pure water 1mL/min, PURGE OFF)
◆ Linearity range:≥600μRIU
◆ Noise:≤2.5nRIU (Pure water, response : 1.5sec)
◆ Response:0.1 , 0.25 , 0.5 , 1 , 1.5 , 2 , 3 , 6 sec
◆ Cell volume:8μL
◆ Flow rate:(Usual) 0.2 to 3.0mL/min;(Max.) 10mL/min (solvent: pure water)

 

Hot Products

ISO 8142 Thermal Insulation Materials Maximum Use Temperature Test Apparatus Introduction: This ...
Lateral Flame Spread Testing For Walls Surfaces Introduction Lateral Flame Spread Testing Equipment ...
Fire Propagation Index Testing Equipment for Laminated Foil BS476-6 FPT.pdf Introduction: BS 476-6 ...
ISO9239 FRPT.pdf Introduction: Critical Radiant Flux is the main parameters of the fire risk for ...
Introduction This Fire Test Equipment is developed base on the standard AS1530.2, test for ...
Introduction: The BS 476-12 Ignitability Tester is designed according to the BS476-12:1991. Method ...