PC Control Laboratory Test Equipment Gas Chromatography Analysis With FID ECD

Country/Region china
City & Province changsha hunan
InquireNow

Product Details

 

PC Control Laboratory Test Equipment Gas Chromatography Analysis With FID ECD

 

 

GC Introduction

The intelligent Gas Chromatograph GC-5400 incorporates advanced modern manufacturing technologies with years of experience in research and development. It is manufactured under a quality system conforming to international standards. The multi functional, easy-to-use and remotely controllable gas chromatograph provides superior performance for all applications.

 

 

Application fields

GC-5400 gas chromatograph plays a critical role in quality control of chemistry, medicine and food industries, and also applicable to quarantine, environment protection, quality supervision, oil, petrochemical industry, forensic analysis, agriculture and commodity inspection.

 

 

Performance characteristics

  • Advanced Microcomputer Control System

With adoption of advanced control technology, the microcomputer temperature control system is highly precise (less than ±0.05℃), reliable and anti-interfering. The system is divided into 5 independent heated zones with maximum temperature up to 400℃. Settable ultimate temperature and overheat protection mechanism ensure a safe operation of the instrument.
Control and operating parameters can be set on the logical and easy-to-use keypad interface (including detector operating parameters). It has functions of self diagnosis, power-off protection, 10 method files saving and invoking, 2 controls of external events, timing start/stop of temperature control, time programming, detector selection, setting and display of range, polarity and current. The set value, actual value, retention and analysis time of each heated zone can be fully displayed.

  • High Performance Large Column Compartment

The large column compartment allows for simultaneous accommodation of capillary column and double packed columns. It is equipped with automated back door mechanism, a rapid heating/cooling device (lowering temperature from 350℃ to 50℃ in 7 minutes), to realize quasi room temperature control. It supports 5 compartment ramps with 6 plateaus.

  • High precise pneumatics with dual stability

The carrier gas pneumatics is designed with constant pressure valve plus constant flow valve for dual stability. Constant pressure valve plus needle valve are used in the air and Hydrogen pneumatics for stable gas regulation. Both valves are in form of digital knobs, which delivers high precision, outstanding repeatability, good reliability and intuitive flow rate adjustment.

  • High-sensitivity and high-stability detector

Up to three kinds of detectors, Flame Ionization Detector (FID), Thermo Conductivity Detector (TCD) and Electron Capture Detector (ECD), are provided for GC-5400. Different combinations of detectors, in series or parallel operation, can meet different application requirements.
The novel FID has lower limit of detection, with ejector nozzle and ions collector easily disassembled or cleaned. The fixed and accurate installation structure of the ejector ensures every instrument has consistent performance.
The high sensitive TCD adopts the high resistant rhenium-tungsten wire, with twofold electronic amplification circuit optional, resulting in maximum sensitivity up to 5000mV·mL/mg. Its unique air insulation structure brings TCD higher stability of performance.
Sensitivity and current selections of pulse modulation ECD constant current source are computerized.

 

 

Technical specifications

Temperature Control
Temperature range7°C ~ 400°C above room temperature, increment 1°C
Temperature control objectsColumn compartment, detector, thermal conductivity cell, injector, accessories
Temperature ramps5-stage
Temperature ramp rate0. 1°C ~ 40°C/min, increment 0. 1°C
Constant Temperature Retention time0 ~ 655 min, increment 1 min
Hydrogen Flame Ionization Detector (FID)
SensitivityM ≤ 1 ×10-11 g/s(C16)
Best testing resultsM ≤ 8 ×10-12 g/s(C16)
Noise≤5×10-14 A
Drift≤6×10-13 A/h
Linear dynamic range≥ 106

 

 

Hot Products

ISO 8142 Thermal Insulation Materials Maximum Use Temperature Test Apparatus Introduction: This ...
Lateral Flame Spread Testing For Walls Surfaces Introduction Lateral Flame Spread Testing Equipment ...
Fire Propagation Index Testing Equipment for Laminated Foil BS476-6 FPT.pdf Introduction: BS 476-6 ...
ISO9239 FRPT.pdf Introduction: Critical Radiant Flux is the main parameters of the fire risk for ...
Introduction This Fire Test Equipment is developed base on the standard AS1530.2, test for ...
Introduction: The BS 476-12 Ignitability Tester is designed according to the BS476-12:1991. Method ...