Home Companies Advanced Instruments Co.,Limited

Lubricating Oil ASTM D217 Cone Needle Penetrometer for Grease Testing

Advanced Instruments Co.,Limited

Contact Us

[China] country

Trade Verify

Address: Hi-tech Developing Industrial Area, Liuyang City,Changsha,Hunan Province,China

Contact name:Sandy

Inquir Now

Advanced Instruments Co.,Limited

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

Lubricating Oil ASTM D217 Cone Needle Penetrometer for Grease Testing

Country/Region china
City & Province changsha hunan
Categories Other Cables
InquireNow

Product Details

ASTM D217 Lubricating Oil and Grease Cone Needle Penetrometer Testing Equipment
 
Summary
The penetrometer is designed and made as per the national standard of People’s Republic of China GB/T 4509-1998/2010 Standard Test Methods for Penetration of Bitumen , GB/T269 Standard Test Methods for Cone Penetration of Lubricating Grease and Petrolatum and ASTM D217 Standard Test Methods for Cone Penetration of Lubricating Grease as well as T0604-2011 Bitumen Penetration Test in the industrial standard of People’s Republic of China JTG E20-2011 Specifications and Test Methods of Bitumen and Bituminous Mixture for Highway Engineering. It is suitable for the asphalt penetration test and grease (or oil fat) cone into the degree of testing. The instrument can also be used for solid granule, powder, colloid, frozen materials such as body, and cheese, sugar, butter, wheat the spray, cream, fermentation and other food raw material inspection, in the food industry, transportation, highway engineering and other industries can be widely used.
 
I. Main technical features
1. Digital display shows the penetration value, eye-catching visual.
2. There are 6 files in the time control device, and the accuracy is high.
3. With functions of mast coarse and fine tuning, convenient adjustment, accurate to needle.
4. This penetrometer is equipped with a pounding fat machine, constant temperature bath, water bath temperature automatic control, multi-usage, instrument is cost-effective.
5. Selection of standard needle, sample dish, thermometer and weight and other different configurations, can be suitable for the national standard 4509-1998 GB/T, 4509-2010 GB/T and E20-2011 T0604-2011 in the measurement of JTG standards
 
The greatest features of this instrument are: advanced mechanical design, easy lift adjustment; digital temperature control table, temperature control is accurate; penetration of digital test of high precision, reliable measurement results.
 
II. Main technical specifications
1. Measurement range: (0~600)penetration
2. Timing device: you can select 5 s, 8 s, 10 s, 12 s, 30 s, and 60 s; Timing error is less than ±0.1 s;
3. Resolution: 0.01 mm;
4. Penetration accuracy: ±1 penetration;
5. Standard needle: 50㎜,2.5g±0.05g
6. Heater power: 200 W;
7. Temperature control accuracy: 25±0.1 ℃ (Note: The ambient temperature shall not be higher than 20 ℃);
8. Temperature control mode: by a high precision digital temperature controller;
9. Constant temperature bath: Hard glass bath;
10. Bath stirring: automatically stirred by a magnetic stirrer;
11. Standard cone: 102.5±0.05 g, as per GB/T269 and ASTM D217;
12. Lifting support: With coarse and fine adjustment functions; it is used to let the needle point just touch the sample surface.
13. Power Supply: AC (220 ± 10%) V, 50Hz, power consumption is not more than 300W.
14. Dimensions: 280mm × 350mm × 700mm (length × width × height).
15. Others: Equipped with a cold light source and a magnifier. It is convenient for instrument operation.
 
 
III.Accessories
NoItemUnitQtyRemark
1Grease workerSet1 
2Bimetal thermometer and holderPiece1 
3Standard needle——By Table 1 configuration———— 
4Weight——By Table 1 configuration———— 
5Sample dish——By Table 1 configuration———— 
6Mercury thermometer——By Table 1 configuration———— 
7Cone penetration sample vesselPiece1 
8O type ring (Ф105×5) ——Mounted on a large sample devicePiece1 
9Standard ConePiece1 
10Needle linkPiece1 
11Glass sinksSet1 
122A fuse (Ф5 × 20)Piece1 
13TripodPiece1 
14Magnetic stirringPiece1 
15Monitor battery (LR44,1.5V button batteries, φ11.5 × thickness of 5)Grain1 

 

Table 1 Instrument configuration table with accessories

ItemGB/T 4509-1998StandardGB/T 4509-2010StandardT0604-2011 in JTG E20-2011 standard
Standard needle50㎜,2.5g±0.05g3Pieces3Pieces3Pieces
60㎜,2.5g±0.05g.——3Pieces——
Sample dishΦ55㎜×H16㎜——3Pieces——
Φ55㎜×H35㎜1Piece3Pieces3Pieces
Φ55㎜×H70㎜Optional3PiecesOptional
Φ70㎜×H45OptionalOptionalOptional
Thermometer(0~50)℃,scale division is 0.1℃1Piece——1Piece
(-8~32)℃,scale division is 0.1℃——1Piece——
(25~55)℃,scale division is 0.1℃——1Piece——
Weight50g2Pieces1Piece2Pieces
100g——1Piece

——

 

 

Hot Products

ISO9239 FRPT.pdf Introduction: Critical Radiant Flux is the main parameters of the fire risk for ...
Introduction This Fire Test Equipment is developed base on the standard AS1530.2, test for ...
Introduction: The BS 476-12 Ignitability Tester is designed according to the BS476-12:1991. Method ...
Product Introduction The smoke toxicity test device (squirrel cage method) is applicable to the GB/T ...
Roofing Fire Test Equipment with Burning Brands by ENV 1187 Test 1 and ISO 12468-1 Product ...
Product Introduction Smoldering characteristic test furnace is mainly used in the fire performance ...