Home Companies Advanced Instruments Co.,Limited

25KVA Primary Current Injection Test Kit High Current Generator Instrument

Advanced Instruments Co.,Limited

Contact Us

[China] country

Trade Verify

Address: Hi-tech Developing Industrial Area, Liuyang City,Changsha,Hunan Province,China

Contact name:Sandy

Inquir Now

Advanced Instruments Co.,Limited

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

25KVA Primary Current Injection Test Kit High Current Generator Instrument

Country/Region china
City & Province changsha hunan
InquireNow

Product Details

 

Primary Current Injection Tester System with Circuit Breaker Timer

 

I. Introduction:

PCI series primary current injection tester is applied in power system for circuit breaker test, protection system test and current transformer test. The current injection test set generates a high current from power supply to simulate the rated current or fault current in the primary circuit of power equipment.

The 1000A/15KVA primary injection test system is designed in integrated model.

 

 

Features:

1 High current output injected to the main circuit of power line to simulate the fault current. Then check whether the protection system will be operated according to the design.
2 High current output injected to the primary of current transformer and then measure the inducted current from secondary
by error measurement instrument to check the ratio error and phase displacement of CT.
3 High current output injected to the main circuit of circuit breaker to simulate the rated current in primary. Then check the stability of circuit breaker according to the temperature rise procedure.

4 This primary current injection test set is also considered as a AC high current source in power equipment or cable test.

5.Current is measured from the secondary of current transformer which is installed in the internal of the current booster.

 

 

III. Specifications:

1Power supplyAC220V or AC 400V, 45Hz~65Hz. The power supply voltage is depends on the power output capacity, as below.
2Typical output current

500A or 1000A or 2000A

Typical output capacity 3KVA or 5KVA or10KVA or15KVA
It can be customized according to your requirements from above specs

3Impendence voltage8%
4Idle current6%
5Current distortion<5%
6Display unit4 and 1/2 digitals current meter
7Maximum measurement error0.5%RDG+5D
8Optional timer1)4 digital timer from 0~9999s / 0~999.9s /0~99.99s, accuracy 0.5%RDG+5D
2)5 digital timer from 0~99999s / 0~9999.9s /0~999.99s, accuracy 0.2%RDG+2D
3)6 digital timer from 0~999999s / 0~99999.9s /0~9999.99s, accuracy 0.1%RDG+1D
9Work temperature0~40 C, Humidity <90%

Hot Products

ISO9239 FRPT.pdf Introduction: Critical Radiant Flux is the main parameters of the fire risk for ...
Introduction This Fire Test Equipment is developed base on the standard AS1530.2, test for ...
Introduction: The BS 476-12 Ignitability Tester is designed according to the BS476-12:1991. Method ...
Product Introduction The smoke toxicity test device (squirrel cage method) is applicable to the GB/T ...
Roofing Fire Test Equipment with Burning Brands by ENV 1187 Test 1 and ISO 12468-1 Product ...
Product Introduction Smoldering characteristic test furnace is mainly used in the fire performance ...