VT Voltage Transformer Test Equipment For CT Current Transformer

Country/Region china
City & Province changsha hunan
InquireNow

Product Details

 

Fully Automatic CT VT Test Equipment

 

Test for current transformer:

  • Excitation curve and parameters test

  • Turns ratio test

  • Ratio and phase error test

  • Polarity mark check

  • Winding resistance measurement

  • Secondary loop burden measurement

  • Error line curve test for protection CT

  • Transient CT parameters test

  • CT nameplate guess

  • Saturation hysteresis loop curve measurement

  • Tests for Potencial Transformer:

  • Turns ratio test

  • Ratio error and phase angle error test

  • Polarity test

  • Secondary burden test

  • Winding resistance test

 

Test for Voltage Transformer

  • Secondary burden test

  • Winding resistance test

  • Polarity test

  • Turns ratio test

  • Ratio error and phase angle error test

 

Applications of CT/ VT Test Equipment:

  • CT nameplate check

  • CT parameters check in work burden

  • CT transient parameters analysis

  • CT ratio and phase error calibration

  • PT routine test

 

Specifications:

Item NameFully Automatic CT VT Test Equipment
Test standardsIEC60044-1, IEC60044-6, IEC60044-2, IEC60044-5, C57.13
Power supplyAC220V±10%, 50/60Hz±10%
Voltage output0.1~180V (AC)
Current output0.001~5A(RMS)
Power output500VA
Max. knee voltage measurement45KV
Current measurementRange0~10A (automatically change range in 0.1/0.4/2/10A)
Error<±0.1%+0.01%FS

 

Voltage measurementRange0~200V (automatically change range in 1V/10V/70V/200V)
Error< ±0.1%+0.01%FS
Turns ratio measurement Range1~35000
1~2000, error<0.05%
2000~5000,error<0.1%
5000~35000,error<0.2%
Phase measurementerror±2min
resolution0.01min
Winding resistance measurementRange0~8kΩ (automatically change range in2ohm/20ohm/80ohm/800ohm/8kohm)
Error< 0.2%RDG+0.02%FS
Maximum resolution : 0.1mΩ
Temperature measurement-50~100 Celsius degree; error<3 Celsius degree
CT Secondary burdenRange0~160ohm (automatically change range in 2ohm/20ohm/80ohm/160ohm)
Error<0.2%RDG+0.02%FS
Maximum resolution : 0.001ohm


PT Secondary burden
Error0~80kohm (automatically change range in 800ohm/8kohm/80kohm)
Maximum<0.2%RDG+0.02%FS
resolution0.1ohm

PT ratio measurement

Range
1~35000
1~10000 error<0.1%
10000~35000 error<0.2%
PT ratio error measurement :Typical error<0.05%,
Maximum Error<0.1%
PT phase angle measurement maximum error < 3min
Make evaluation for test results according to selected standards
Make word report for test result
Make word reports one time for multi-group test records on the PC
Calculate the ratio errors and phase angle errors at rated burden and working burden in one time test
Compare excitation curves with saved excitation curves in the same window
Memory capacity>1000 groups test results
Working condition temperature-10℃~50℃; moist ≤90%
 

 

Accessories List of CPT-I CT VT Test Equipment

NamequantityDescription
Main Unit1 Set 
3M mask cable2 RootsTest cable for power out and CT secondary connection
10M mask cable1 RootTest cable for CT primary connection
Grounding cable1 Root 
Big test pliersPCSOne red and one black
Test gasketPCSTwo red and two black
Test pin4 PCSTwo red and two black
Test pliers12 PCSThree red and nine black
Short connection cable1 RootIncluding six connection terminals
3A fuse3 PCS 
Power cable1 Root 
Accessories bag1 PC 
Production disk1 PCInclude Analysis application and user manual
User manual1 Copy 
Inspection report1 Copy 

 

Hot Products

ISO9239 FRPT.pdf Introduction: Critical Radiant Flux is the main parameters of the fire risk for ...
Introduction This Fire Test Equipment is developed base on the standard AS1530.2, test for ...
Introduction: The BS 476-12 Ignitability Tester is designed according to the BS476-12:1991. Method ...
Product Introduction The smoke toxicity test device (squirrel cage method) is applicable to the GB/T ...
Roofing Fire Test Equipment with Burning Brands by ENV 1187 Test 1 and ISO 12468-1 Product ...
Product Introduction Smoldering characteristic test furnace is mainly used in the fire performance ...