Home Companies Guangzhou MeCan Medical Limited

Fully Automated Dry Chemistry Analyzer For Anti Coagulation Whole Blood , Serum , Plasma

Guangzhou MeCan Medical Limited
Active Member

Contact Us

[China] country

Address: RM718, EASTERN BUILDING, XIAOBEI, YUEXIU, GUANGZHOU, CHINA.

Contact name:Andy

Inquir Now

Guangzhou MeCan Medical Limited

Fully Automated Dry Chemistry Analyzer For Anti Coagulation Whole Blood , Serum , Plasma

Country/Region china
City & Province guangzhou guangdong
InquireNow

Product Details

 

Fully Automated Dry Chemistry Analyzer For Anti Coagulation Whole Blood , Serum , Plasma

 

Model:MC-SMT100V

 

MC-SMT100V is a portable automatic chemistry analyzer which is applied to clinical biochemistry analysis with lithium heparin anticoagulant whole blood, serum and plasma. And MC-SMT100V covers various applications from emergency departments to clinical labs, from ICU to surgery centers, from anesthesia department to respiratory care, from home to ambulance.

 

In addition, the MC-SMT100V system consists of a 5-kg portable analyzer and pre-configured reagent, or “rotor”, disks that enable veterinarians to obtain a clear, comprehensive picture of a patient’s condition, and veterinarians needn’t add reagents by themselves.

 

What is the features of our dry chemistry analyzer?

Simple operation

Free of centrifugation, water treatment system and professional doctor. Anyone can operate only by 3 steps. Add 100ul whole blood into disc, put disc into analyzer and delay 12 minutes to print report.

 

Little sample volume

Sample volume is 10-20% of normal chemistry analyzer.

 

Accurate Result

Test sample and dilution volume measured by mould, without random error.

 

No carryover

Portable,5 Kg, 0.02m3

Provide with AC and DC power, suitable for use at movable place and outdoor.

 

Free maintenance

Auto QC and real time Calibrate.

Stroboscopic xenon lamp, service life is over one hundred million times.

No internal fluid flow, no pump and valve, decrease machine fault.

 

Technical data

Sample typeAnti-coagulation whole blood, serum, plasma
Sample volume100ul
Bar codeTwo-dimensional bar code
Testing time12mini/person
Testing principleabsorption spectroscopy, transmission turbidimetry
Testing methodend point, kinetic, fixed time, turbidmetry, etc.
Temperature37 ±0.2 degrees celsius
Absorbance0-4.5Abs
Resolution0.001Abs
Carryover0
QC & Calibrateauto test in real time
Work environmentTemperature:10-32 degrees Celsius, Humidity: <90%
Optic systemReversed optic. 340nm, 405nm, 450m, 505nm, 546nm, 578nm, 630nm, 850nm
Light source12V/20W,.Tungsten halogen lamp’s life span reaches over 2500hours
Power supplyAC100V-240V,50-60Hz
Power70W
Interface7.0 inch True color LCD touch screen, multi-language choice.
Vet version is optional
Storage>100000 results
Printerbuilt-in thermal printer and external printer
Data port4 USB, 1 RS232. Software upgrade function by WIFI
Weight5KG
Size31cm(H)*21cm(W)*28(L)cm
Animal typesOver10 species

 

How to use our fully automated dry chemistry analyzer?

Step 1: Add Sample

Simply collect 0.1cc of whole blood, serum or plasma, and transfer it to the self-contained reagent disc. The single use, disposable disc contains all the reagents and diluent necessary to perform a complete fixed multi-test panel.

 

Step 2: Insert Disc

Follow the touch screen commands. Place the disc into the analyzer drawer, enter requested information and the biochemistry analyzer does the rest. In approximately 12 minutes, results are ready.

 

 

Step 3: Read Results
Complete panel results including patient demographics, chemistry concentrations, reference ranges, sample integrity indices and iQC are available on the full color display, printed on a self-adhesive print out, transmitted to an external printer, The automatic biochemistry analyzer will store on-board up to 100000 patients and quality control results.

 

The types of animal biochemistry reagent disc

1.The 14 Comprehensive Diagnostic Parameters:K+, Na, ALT, ALB, ALP, AMY, TBIL, GLU, GGT, CHE, CREA, TP, UA, UREA, GLOB*
2.The 13 Health Check ParametersALT,ALB, AST, AMY, CA, CREA, GLU, TBIL, CK,TG,UREA, PHOS, TP, GLOB*
3.The 10 Emergency and Severe Disease ParametersK, Na, Cl,TCO2, ALT, AMY, GLU, UREA, CREA, CHE
4.The 9 Liver Function ParametersALT, AST, ALB, ALP, TBA, TBIL, GGT, TC, TP
5.The 8 Kidney Function ParametersCA, PHOS, TCO2, ALB, GLU, UREA, CREA,UA
6.The 7 Electrolyte ParametersK+, Na+, Cl, CA, TCO2, Mg, PHOS
7.The 9 Pre-operation Test ParametersALT, ALP, AST, GLU, UREA, CREA, TP, LDH, CK
8.The 11 Birds and crawlersK+, Na+, CA, PHOS, ALB, AST, CK, TBA, GLU, TP, UA, GLOB*
9. The OthersIt is workable to customize according to your request.

 

 

What more detailed picture?

 

 

 

 

FAQ

Q: What are the power requirements to operate SMT 100 analyzer?

A: The analyzer requires 100-240 volts AC, 50-60 Hz.

 

Q: What is the shelf life of the reagent discs?

A: The reagent discs can be stored for up to 12 months at 2-8°C.

 

Q: Can the expired reagent discs be used?

A: No, the result of the test will be unreliable.

 

Q: How long can the reagent disc be used after removing from the foil pouch?

A: After opening the pouch, the disc should be used within 20 minutes. Do not place the disc back into the refrigerator for later use.

 

Q: Can reagent discs be used again?

A: No, it can only be used once. It is a single-use disposable reagent disc. One disc one sample.

 

Q: What types of samples can be used with the MC-SMT100V analyzer?

A: The sample can be whole blood, plasma or serum.

 

Q: What is the sample volume required for a test?

A: 100ul is required to run a test. In case of rechecking, it is recommended that collecting blood sample is not less than 250ul.

 

Q: Before testing, does the reagent disc need to take out from refrigerator to guarantee the test temperature?

A: Yes, to avoid congealing and guarantee test temperature, before unpack and test, reagent disc

have to be placed 20 minutes after taking our from refrigerator or low temperature storage tank.

 

Q: In the process of sample and control test, when clicking STOP button, can the test disc be used as a new disc again?

A: The stopped test disc can’t be used again. If it is not must situation, please don’t stop it.

 

Q. Do the users need to add reagent?

A: No, the reagent is already packed well in each of the disc hole before packing foil pouch.

 

Q: How to maintain the instrument?

A: Keep the instruments shell and drawer clean. Compared to the traditional analyzer, our instrument has less maintenance.

 

Hot Products

Handheld Palm Portable Ultrasound Scanner , Ultrasonic Bladder Scanner With Trolley Model:MC-PBS-V31 ...
Thermal Ultrasonic Color Video Printer Print On Thermal Sensitive Paper Model:MC-P93W-Z Technical ...
MSK Portable Ultrasound Scanner Machine With 18 MHz High Frequency Linear Probe Model:MC-EBit 50 ...
High Resolution 15 Inch LED Fully Digital Trolley Ultrasound Scanner Model:MC-370 What is the detail ...
Portable Black And White Ultrasound Machine, Ultrasonicblack WhiteImaging System Model:MC-SS-7 ...
4D Color Doppler Trolley Ultrasound Machine Fast-Light-Quiet-Smart Model:MC-I3 The revolutionary i3 ...