Plastic Rapid Saliva Self Test Kit Avoid Sunshine For SARS CoV 2 Virus Antigen

Country/Region china
City & Province shenzhen
Categories R/C Toys
InquireNow

Product Details

Rapid Test Kit SARS-CoV-2 Antigen Saliva Rapid Test Self Testing Virus Antigen Use High QualitY One Test Easy For Use


Intend Use

  • The Labnovation SARS-CoV-2 antigen saliva rapid test kit is intended for the qualitative detection of SARS-CoV-2 antigen in human saliva samples from novel coronavirus suspected person with symptoms within 7 days from onset.
  • The antigen saliva rapid test kit is an immunochromatography assay. According to the gold immunochromatographic test principle, double antibody sandwich method was used to detect SARS-CoV-2 nucleocapsid antigen in the samples.

 

 

Product Details

ItemValue
NameSARS-CoV-2 Antigen Saliva Rapid Test Kit 
Warranty24 Months
Safty StandardISO13485
Sample TypeSaliva Sample
Sample volume3 Full drops
Test TimeWithin 15 minutes
Store temperatureStore 2-30 ℃
PrincipleImmunochromatography assay

 

Product  Feature

  • Fast, Result in 15 minutes
  • Simple, Easy to use and no extra instrument
  • Reliable, High accurtacy, specificity and sensitivity
  • Inexpensive, cost-efficiency
  • Non-invasive

Diagnostic Accuracy

SARS-CoV-2 Antigen Saliva Rapid Test Kit
SensitivitySpecificityTotal ACCURACY
96.19%100.00%99.21%


 
Main Components

  • Test Cassette
  • Saliva Collector
  • Disposable Pipettes
  • Sample Extraction Buffer (single dose)
  • Instruction Insert

Use Step

  • Take sample tube with prefilled sample extraction buffer and remove the sealed film of the sample tube. Then put the tube into tube stand (in the outer box).
  • Open the tear hole of the aluminum foil bag, take out the disposable pipette and test cassette, lay them flat.
  • Put the saliva collection bag to lips and let the saliva flow into the bag.
    Place the tip of tongue against the upper or lower tooth root to enrich saliva, and then swallow saliva to the throat without ingesting saliva to esophagus, followed by returning saliva to the mouth. Repeat the process for 5 times.

  • Draw 2/3 dropper range(300ul)of saliva from saliva collection bag with the help of pipette and transfer the entire contents into the extraction buffer of the sample tube. And blow the liquid for 10 times, squeeze bottom of the sample tube to ensure the saliva is thoroughly mixed.
  • Close the cap of the sample tube. Shake the specimen collection tube at least three times vigorously to mix the saliva sample with extraction buffer. Attention: Please avoid bubbles!
  • Add 3 full drops of the treated sample extraction buffer (about 70μL-100μL) vertically into the sample well of the test cassette.
    Read the result at 15 minutes. Do not interpret the result after 20 minutes.

 
Result Interpretation

  • POSITIVE: Two (2) distinct colored lines appear. One line should be in the control region (C) and the other line should be in the test region (T).

  • NEGATIVE: One (1) colored line appears in the control region(C). No apparent colored line appears in the test region (T).

  • INVALID: No colored lines appear, or control line fails to appear, indicating that the operator error or reagent failure. 

 

 
Virus Sources

Global high frequency mutationAlpha / B.1.1.7(U.K.)Beta I B.1.351(South Africa)
Gemma I P.1(Brazil)Kappa I B.1.617.1(India)Delta I B.1.617.2(India)
C.37,ectAlpha I B.1.17(U.K.)B.1.36.16.etc
A.2.5,etcA.23.1Alpha I B.1.17(U.K.)
B.1.1.33.etcC.1.1.etc.Omicron

FAQ

  • The delivery time?

As we're manufacturer and our daily production capacity is 1000000, so the shipping as soon as received payment.

  • The accuracy of results?

We conducted a large number of clinical trials, the sensitivity and specificity of above 95%, the overall accuracy of 99%, the accuracy of the detection results is very high.

  • Type of shipping ?

Air cargo or ocean cargo.

 

Other infromation

  • All test components are only intended to be used for this test. Do not reuse the test or test components.
  • The test should be carried out immediately or within one hour after opening the foil pouch (18-30°C, humidity <60%).
  • Samples be processed as soon as possible after sample collection. If the test cannot be performed immediately, the sample should be stored in a sealed state, stored at 2~8°C for 8 hours. Long-term storage is not recommended.
  • Poor vision, color blindness or poor lighting may affect your ability to interpret the test correctly.

 

Hot Products

HbA1c Analyzer LD-560 HPLC System Fully Automated Analyzer For HbA1c Testing Intended Use LD-560 ...
LD-560 HbA1c Analyzer HPLC System for HbA1c Testing Intended Use LD-560 HbA1c analyzer is intended ...
LD-560 HbA1c Analyzer HPLC System for HbA1c Testing Intended Use The Fully Automated HbA1c Analyzer ...
LD-560 HPLC System for HbA1c Testing The Fully Automated HbA1c Analyzer is used in conjunction with ...
Analyzer For HbA1c Testing Labnovation Latest Analyzer LD-560 HbA1c Analyzer IFCC Certificated ...
Analyzer HbA1c LD-560 Latest Analyzer For HbA1c Testing Dual Mode For Option NGSP Certification ...