Home Companies Labnovation Technologies, Inc.

LD-100 Fully Automatic POCT HbA1c Analyser Hematology Testing Analyzer

Labnovation Technologies, Inc.
Active Member

Contact Us

[China] country

Address: 101 and 5th Floor, Building 1, No. 68,18th Road, Guangming Hi-Tech Park, Tangjia Community, Fenghuang Street, Guangming District, Shenzhen 518107 ,China

Contact name:Aimee li

Inquir Now

Labnovation Technologies, Inc.

LD-100 Fully Automatic POCT HbA1c Analyser Hematology Testing Analyzer

Country/Region china
City & Province shenzhen
InquireNow

Product Details

HbA1c Analyzer POCT HbA1c Detection Analyzer LD-100 Fully Automatic Hematology Detection Analyzer

Intended Use

Labnovation HbA1c Analyzer LD-100 POCT Analyzer is intended for the percent determination of hemoglobin A1c (HbA1c) in human whole blood which is a semi-automatic instrument used to analyze glycated hemoglobin. LD-100 is small and light, it can be used to detect of HbA1c in medical units at all levels. Fually Automatic system can help the test half work with double results.

Specifications

ModelLD-100
MethodFluorescent Immunoturbidimetry
Operating Type1-Step, fully automatic
Measurement TimeLess than 3 minutes
Sample Volume4ul
Sample TypeWhole blood
Data storage7000
Measurement RangeHbA1c 4.0~15%(NGSP Unit)
eAG 68-385mg/dl(mmol/l)
Operating ConditionTemperature:15~35℃
Humidity:15~80%R.H
Storage ConditionAnalyzer:10-60℃; Test kit: 2~8℃
Voltage12VDC-3.33A
Analytical wave-length510nm and 580nm.
CertificationNGSP, IFCC

 

 

PRINCIPLE

  • Uses the (borate affinity) fluorescent immunoturbidimetry
  • Push a mixture containing a fluorescent borate conjugate into an integrated test cup and mix to dissolve sufficiently.
  • The blood samples in the sample collector are then pushed into the buffer and mixed to release the hemoglobin from the red blood cells.
  • The total concentration of hemoglobin depends on the initial reduced fluorescence signal.
  • Fluorescent borate conjugates bind to glycosylated hemoglobin, and glycosylated hemoglobin is determined by detecting the decrease of fluorescent active ingredients.
  • The percentage of glycosylated hemoglobin in total hemoglobin can be determined.

Feature

  • One-Step Testing, Fully Automatic
  • Protable, easy to carry 
  • Fast test speed, WIthin 3 minutes
  • Battery Integrated
  • Cv<3%, Excellent Correlation With HPLC
  • RFID For Batch Management
  • Color touch screen
  • External printer (Blue-tooth)
  • USB Port, LIS Support

 

Reliable

IFCC calibratorNormalAbnormalNormalAbnormal
Mean HbA1c%5.49.65.39.2
CV (%)2.5%1.9%2.4%1.8%

 

Use Step

  • Place cartridge in analyzer
  • Push bead into reagents
  • Insert sample into cartridge

 

Performance Parameters

  • Accuracy: Is tested with the reference material as samples, and the relative deviation of the determination results of the analyzer should be within the range of ±8%.
  • Precision:Samples with a concentration of 4.0%-6.5% are detected, sample coefficient of variation (CV) of the test results is not more than 3%.
  • Linearity:In the range of 4%-16% of HbA1c, the linear correlation coefficientrof the test results should be no less than 0.9900.
  • Stability:Within 8 hours after the instrument is turned on and stable, the relative deviation of the test results is not more than ±3%.
  • Functions of the analyzer:The function of report output in English;  Abnormal alarm function.

 

Certificated

 

 

Hot Products

HbA1c Analyzer Fully Automated HbA1c Analyzer LD-600 (HPLC) Intended Use The Fully Automated HbA1c ...
Hematology Analyzer Fully AutomatED HbA1c Analyzer LD-560 HbA1c Analyzer Intended Use The Fully ...
HbA1c Test Analyzer LD-560 HbA1c Testing With HPLC System Latest Medical Hematology Equipment ...
HbA1c Analyzer LD-560 HbA1c Test Analyzer HPLC System For HbA1c Testing Hematology Test Analyzer ...
HbA1c Analyzer LD-560 Fully Automaic HbA1c Testing Analyzer HPLC System For Hemoglobin Testing ...
HbA1c Analyzer Fully Automatic LD-560 Hemoglobin Detection Analyzer HPLC Method Support Intended Use ...