OEM Immunochromatography Antigen Rapid Test Kit For SARS-CoV-2

Country/Region china
City & Province shenzhen
InquireNow

Product Details

SARS-CoV-2 Antigen Rapid Test Kit (Immunochromatography)

Product Details

ItemValue
Model NumberLX-401301
Type20 Tests
Warranty24 Months
Power SourceInstruction Manual
Quality CertificationCE
Safty StandardISO13485
After-sale ServiceOnline technical support
Sample volume3 Full drops
Test SpeedWithin 15 minutes

 
Product  Feature

Intend Use
This rapid test kit is intended for the qualitative detedtion of SARS-CoV-2 infection from patients.
 
Main Components
Test Cassettes
Sample tubes 
Sample extraction
Swabs
Instruction for use
 
Use Step

  • Add 550μL sample extraction (about 22-24 drops) into the sample tube.
  • Insert the swab into the sample tube prefilled with extraction buffer. Mix well and squeeze the swab 10-15 times by compressing the wall s of the tube against the swab.
  • Roll the swab head against the inner wall of the tubes as you remove it. Try to release as much liquid as possibe. Dispose of the used swab in accordance with your biohazard waste disposal protocol.
  • Close the cap of the sample tube.
  • Add 3 full drops of the mixed solution vertically into the sample well (S) of the test cassette.


 
Result Interpretation

  • POSITIVE: Two (2) distinct colored lines appear. One line should be in the control region (C) and the other line should be in the test region (T).

  • NEGATIVE: One (1) colored line appears in the control region(C). No apparent colored line appears in the test region (T). 

  • INVALID: No colored lines appear, or control line fails to appear, indicating that the operator error or reagent failure.

 

 
Virus Sources

Global high frequency mutationAlpha / B.1.1.7(U.K.)Beta I B.1.351(South Africa)
Gemma I P.1(Brazil)Kappa I B.1.617.1(India)Delta I B.1.617.2(India)
C.37,ectAlpha I B.1.17(U.K.)B.1.36.16.etc
A.2.5,etcA.23.1Alpha I B.1.17(U.K.)
B.1.1.33.etcC.1.1.etc. 

 
Certificate

Hot Products

HbA1c Analyzer LD-560 HPLC System Fully Automated Analyzer For HbA1c Testing Intended Use LD-560 ...
LD-560 HbA1c Analyzer HPLC System for HbA1c Testing Intended Use LD-560 HbA1c analyzer is intended ...
LD-560 HbA1c Analyzer HPLC System for HbA1c Testing Intended Use The Fully Automated HbA1c Analyzer ...
LD-560 HPLC System for HbA1c Testing The Fully Automated HbA1c Analyzer is used in conjunction with ...
Analyzer For HbA1c Testing Labnovation Latest Analyzer LD-560 HbA1c Analyzer IFCC Certificated ...
Analyzer HbA1c LD-560 Latest Analyzer For HbA1c Testing Dual Mode For Option NGSP Certification ...