Rapid Antigen Test Kit CoV-2 Antigen Saliva Rapid Test Kit High Specificity 1 Test Professional Use Rapid Test Kit


Intend Use
The test kit intended for the qualitative detection of SARS-CoV-2 antigen in human saliva samples, it also can detect who have suspected with symptoms within 9 days from onset. Test result can be used for early triage and rapid kmanagement of suspected populatio but not the only diagnosis basis, for the negative results it need to do futher nucleic acid and detection.
 
Product Details

ItemValue
NameSARS-CoV-2 Antigen Rapid Test Kit
Model NumberLX-401601
Type1 Test / Kit
Warranty24 Months
CertificationCE, MSDS
SpecimenSaliva
Sample volume3 Full drops
Test Speed<15 minutes
sensitivity94.29%
specificity99.00%
Total coincidence rate98.02%

 
Product  Feature

  • Safety and reliable, CE and ISO Certificated
  • Protable and convience
  • Lower cost with high quality
  • High accuracy, sensitivity and specificity
  • Fast recation with excellent performance

 

  • Main Components
  •  1 Test Cassette
  •  1 Saliva Collector 
  •  1 Collection Tube 
  •  1 Sample Extraction Buffer (Single does)
  •  1 Instruction Manual

 Sample Collection

  • 30 minutes before sampling, please do not eat, smoke, drinking alcohol or drinks and the sample should not be inactivated.
  • Bubbles are likely to occur during sample processing and blowing. Do not add bubbles when dropping samples to the sample well of the test cassette.


Use Step

  • Open the cap of the collection tube and istall saliva collector.
  • Put the collection tube with saliva collector close to lips and let the saliva flow into the collection tube. Tje volum of saliva needs to be half of 0.5 scal mark(0.25).
  • Screw the sample extraction buffer carefully.

  • Add all sample extration buffer to the collection tube. Discard the saliva collector, tighten the cap onto the specimen collection tube.
  • Shake the specimen collection tube at least three time vigorously to mix the saliva and the extraction buffer. Squeeze bottom of the collection tube ensure the saliva is thoroughly mixed.
  • Add 3 full drops of the solution to the sample well(S). Read the result at 15 minutes. Do not interpret the result after 20 minutes.

 
Result Interpretation

  • POSITIVE: Two (2) distinct colored lines appear. One line should be in the control region (C) and the other line should be in the test region (T).

  • NEGATIVE: One (1) colored line appears in the control region(C). No apparent colored line appears in the test region (T). The negative result does not indicate the absence of analytes in the sample, it only indicates the level of tested analytes in the sample is less than the minimum detection limit.

  • INVALID: No colored lines appear, or control line fails to appear, indicating that the operator error or reagent failure. Verify the test procedure and repeat the test with a new testing device.

 
 
Virus Sources

Global high frequency mutationAlpha / B.1.1.7(U.K.)Beta I B.1.351(South Africa)
Gemma I P.1(Brazil)Kappa I B.1.617.1(India)Delta I B.1.617.2(India)
C.37,ectAlpha I B.1.17(U.K.)B.1.36.16.etc
A.2.5,etcA.23.1Alpha I B.1.17(U.K.)
B.1.1.33.etcC.1.1.etc.Else.

 Other Information

  • This kit is a qualitative detection, which cannot determine the exact content of antigen
  • The strength of the quality control line does not mean the quality of the test kit. As long as its color is clear and visible, that means it is effective
  • Waste should be treated in accordance with infectious substances and should be discarded properly.
  • Keep away from children. Any child under age 13 shouldn’t perform the test without parental guidance, or professional aid.

Certificate

Hot Products

HbA1c Analyzer LD-560 HPLC System Fully Automated Analyzer For HbA1c Testing Intended Use LD-560 ...
LD-560 HbA1c Analyzer HPLC System for HbA1c Testing Intended Use LD-560 HbA1c analyzer is intended ...
LD-560 HbA1c Analyzer HPLC System for HbA1c Testing Intended Use The Fully Automated HbA1c Analyzer ...
LD-560 HPLC System for HbA1c Testing The Fully Automated HbA1c Analyzer is used in conjunction with ...
Analyzer For HbA1c Testing Labnovation Latest Analyzer LD-560 HbA1c Analyzer IFCC Certificated ...
Analyzer HbA1c LD-560 Latest Analyzer For HbA1c Testing Dual Mode For Option NGSP Certification ...