Simple Operation COVID-19 Saliva Self Test Kit For Suspected Infected People

Country/Region china
City & Province shenzhen
Categories Laser Pointers
InquireNow

Product Details

Rapid Test Kit COVID-19 Antigen Saliva Rapid Test Kit 1 Test Self Testing Simple Operation High Accuracy Easy Use Test Kit


Intend Use

SARS-CoV-2 antigen saliva rapid test kit is intended for the qualitative detection of SARS-CoV-2 antigen in human saliva sample from novel coronavirus suspected person with symptoms within 9 days from onset. The test result can be used for early detection and triage of people suspected of being infected.Further nucleic acid detection should be carried out for suspected population whose antigen test result is positive or negative.

 

Product Details

ItemValue
NameSARS-CoV-2 Antigen Saliva Rapid Test Kit (Self Test)
Model NumberLX-401602
Type 1 Test / Box
Warranty18 Months
Quality CertificationCE
Safty StandardISO13485
Sample TypeSaliva
Sample volume3 Full drops
Test SpeedWithin 10-15 minutes
Total AccuracyOver 95%
Sensitivity94.29%
Specificity99.00%

 

Product  Feature

  • Non-invasive
  • Simple to use
  • Self Testing, not need extra instrument
  • Saliva Sample, more comfortable than others


Advantage

  • Can be used in a wide variety of non-laboratory settings
  • Test results in 15 minutes
  • Stable, with high accuracy
  • Safety and reliable, high accuracy, specificity and sensitivity

 
Main Components

  • 1 Test Cassette
  • 1 Saliva Collectors With Collection Tube
  • 1 Sample Extraction Buffer
  • 1 Instruction Manual

 
Use Step

  • Open the cap of the collection tube and istall saliva collector.
  • Put the collection tube with saliva collector close to lips and let the saliva flow into the collection tube. Tje volum of saliva needs to be half of 0.5 scal mark(0.25).
  • Screw the sample extraction buffer carefully.

  • Add all sample extration buffer to the collection tube. Discard the saliva collector, tighten the cap onto the specimen collection tube.
  • Shake the specimen collection tube at least three time vigorously to mix the saliva and the extraction buffer. Squeeze bottom of the collection tube ensure the saliva is thoroughly mixed.
  • Add 3 full drops of the solution to the sample well(S). Read the result at 15 minutes. Do not interpret the result after 20 minutes.

 
Result Interpretation

  • POSITIVE: Two (2) distinct colored lines appear. One line should be in the control region (C) and the other line should be in the test region (T).

  • NEGATIVE: One (1) colored line appears in the control region(C). No apparent colored line appears in the test region (T). The negative result does not indicate the absence of analytes in the sample, it only indicates the level of tested analytes in the sample is less than the minimum detection limit.

  • INVALID: No colored lines appear, or control line fails to appear, indicating that the operator error or reagent failure. Verify the test procedure and repeat the test with a new testing device.

 

 
Virus Sources

Global high frequency mutationAlpha / B.1.1.7(U.K.)Beta I B.1.351(South Africa)
Gemma I P.1(Brazil)Kappa I B.1.617.1(India)Delta I B.1.617.2(India)
C.37,ectAlpha I B.1.17(U.K.)B.1.36.16.etc
A.2.5,etcA.23.1Alpha I B.1.17(U.K.)
B.1.1.33.etcC.1.1.etc. 

 
Precaution

  • For IN VITRO diagnostic use only.
  • Waste should be treated in accordance with infectious substances and should be discarded properly.
  • This kit is a qualitative detection, which cannot determine the exact content of antigen
  • The extraction reagent contains preservative agent which may be toxic if ingested. When disposed of through a sink, flush with a large volume of water.
  • False negative results may be caused by unreasonable sample collection, transport and treatment, and low viral load in samples.
  • The kit is a disposable rapid test kit, which is only used for the detection of human saliva samples. The operation should be carried out strictly according to the instructions. Do not use expired or damaged products.

FAQ

  • Manufacturer or Trade Company?

We' re manufacturer, we have our own factoty. Dust-free workshops with advanced machines and professional workers.

  • Register your products in our country?

Yes welcome. We can offer full files for you to register.

  • Production quantity?

It depends on the specification of the products. For big orders, we can produce 100k-250k per day.

 

 

 

Hot Products

HbA1c Analyzer LD-560 HPLC System Fully Automated Analyzer For HbA1c Testing Intended Use LD-560 ...
LD-560 HbA1c Analyzer HPLC System for HbA1c Testing Intended Use LD-560 HbA1c analyzer is intended ...
LD-560 HbA1c Analyzer HPLC System for HbA1c Testing Intended Use The Fully Automated HbA1c Analyzer ...
LD-560 HPLC System for HbA1c Testing The Fully Automated HbA1c Analyzer is used in conjunction with ...
Analyzer For HbA1c Testing Labnovation Latest Analyzer LD-560 HbA1c Analyzer IFCC Certificated ...
Analyzer HbA1c LD-560 Latest Analyzer For HbA1c Testing Dual Mode For Option NGSP Certification ...