Home Companies ATMARS INDUSTRTY CO., LIMITED

Drive In Walk In Environmental Test Chamber For Automotive Testing 16.28m³

ATMARS INDUSTRTY CO., LIMITED
Active Member

Contact Us

[China] country

Address: No.1 Yanfa 1st Road, Songshan Lake High-tech Industrial Development Zone, Dongguan City 523000, Guangdong Province, China.

Contact name:Wu

Inquir Now

ATMARS INDUSTRTY CO., LIMITED

Drive In Walk In Environmental Test Chamber For Automotive Testing 16.28m³

Country/Region china
City & Province dongguan guangdong
Categories Prefab Houses
InquireNow

Product Details

Custom-built Drive in Environmental Test Chambers for Automotive Testing

 

 

What is a Walk-In Chamber?
Walk-In Chambers from ATMARS serves as an ideal test site for large components, assemblies, and finished products. We manufacture both Panel (modilar) Walk-In Chambers and Solid (welded) Walk-In Chambers and can be configured as a temperature chamber or a temperature humidity chamber. A Panel Walk-In Chamber is made from lightweight insulated panels for fast and easy installation.

 

ATW/AHW Configurations:
ATW Series - Temperature only
AHW Series - Temperature and humidity capability

 

Available in FOUR standard temperature ranges:
Type A: -20℃ to +150℃
Type B: -40℃ to +150℃
Type C: -60℃ to +150℃
Type D: -70℃ to +150℃

Standard humidity range: 20%RH to 98%RH (Optioal lower humidity is available.)

 

Technical Specifications of AHW-16 SERIES Walk-in Environmental Chambers
Performance is based on ambient temperature +20 ℃ or circulating water temperature +25 ℃, empty load no specimen.
ModelAHW-16AAHW-16BAHW-16CAHW-16D
T&H Adjustment ModeSmart balanced temperature (humidity) control - BT(H)C
PerformanceTemperature Range-20℃ to +150℃-40℃ to +150℃-60℃ to +150℃-70℃ to +150℃
Temperature Fluctuation±0.5℃
Temperature Uniformity±2.0℃
Temperature Devitaion±2.0℃
Heat-up Rate (Average)From -20℃ to +150℃ 3℃/min.From -40℃ to +150℃
3℃/min.
From -60℃ to +150℃
3℃/min.
From -70℃ to +150℃
3℃/min.
Cool-down Rate (Average)From +20℃ to -20℃
1℃/min.
From +20℃ to -40℃
1℃/min.
From +20℃ to -60℃
1℃/min.
From +20℃ to -70℃
1℃/min.
Humidity Range20%RH to 98%RH
Humidity Fluctuation±2.5%RH
Humidity Deviation±3.0%RH when Humidity>75%RH;
±5.0%RH when Humidity≤75%RH.
Workspace Volume16.28m³
Workspace DimensionsW2000xD3700xH2000mm
Exterior DimensionsW2350xD5700xH2600mm
MaterialInterior#SUS304 Stainless Steel
SealImported silicone seal
InsulationExpanded foam & fiberglass
ExteriorCold-rolled steel with powder coated surface
SystemHeatingNichrome Resistance Wire Heater
RefrigerationMechannical Refrigeration System
HumidificationStainless Steel Humidifier (Vapor generator system)
ControllerProgrammable Touch-screen Controller
Noise Level≤70dB (A-weighted sound pressure level measured at a distance of 1.0 meter)
Allowable Ambient ConditionsTemperature: +5℃ to +35℃;
Relative humidity: ≤85%RH (No condensation);
Air pressure: 86kPa to 106kPa.
Power SupplyAC 380 (1±10%)V (50±0.5)Hz 3 Phase 4 Wire plus Earth Wire
Custom options are available.

 

Test Standards Conformance
GB/T 10586-2006 Specifications for damp heat chambers
GB/T 10592-2008 Specification for low/high temperature test chambers
GB/T 2423.1-2008 Environmental testing - Part 2: Test methods - Tests A: Cold
GB/T 2423.2-2008 Environmental testing - Part 2: Test methods - Tests B: Dry heat
GB/T 2423.3-2016 Environmental testing—Part 2: Testing method—Test Cab: Damp heat,steady state
GB/T 2423.4-2008 Environmental testing for electric and electronic products - Part 2: Test method - Test Db: Damp heat, cyclic (12h+12h cycle)
GB/T 2423.22-2012 Environmental testing - Part 2: Tests methods - Test N: Change of temperature
GJB 150.3A-2009 Laboratory environmental test methods for military material - Part3: High temperature test
GJB 150.4A-2009 Laboratory environmental test methods for military material - Part4: Low temperature test
GJB 150.9A-2009 Laboratory environmental test methods for military material - Part9: Damp heat test
IEC 60068-2-1:2007 Environmental testing - Part 2-1: Tests - Test A: Cold
IEC 60068-2-2:2007 Environmental testing - Part 2-2: Tests - Test B: Dry heat
IEC 60068-2-14:2009 Environmental testing - Part 2-14: Tests - Test N: Change of temperature
IEC 60068-2-30:2005 Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle)
IEC 60068-2-78:2012 Environmental testing - Part 2-78: Tests - Test Cab: Damp heat, steady state

 

Hot Products

Programmable Temperature and Humdity Chambers for Environmental Testing Test Standards Conformance ...
What is a TEMPERATURE HUMIDITY TEST CHAMBER ? ATMARS AH series reach-in / compact environmental test ...
Temperature and Humdity Control Chambers for Thermal and Humidity Test What is a TEMPERATURE ...
Constant Temperature and Humdity Chambers for Solar Cell Testing AT/AH Configurations: AT Series - ...
Temperature Humdity Controlled Chambers for Automotive Testing What is a TEMPERATURE HUMIDITY TEST ...
High and Low Temperature Chamber for Thermal Cycling Test Engine In additional to being much more ...